Official Magnelab Australia Distributor
Magnelab serves the energy monitoring industry with a standard line of precision current transformers. These include the flexible RopeCT® (Rogowski coil), split-core ‘opening type’ current transformers, ‘non-opening type’ toroidal current sensors, and precision potential transformers.
Mgnelab offer the best of both worlds — quick turn-around of smaller quantities, as well as larger volume competitive pricing. Their offshore advantages include the lowest labor costs in the Western hemisphere, making thierpricing competitive with suppliers anywhere!
Magnelab is an ISO 9001:2008 certified company, maintaining our tradition of quality and continual process improvement.
- Magnelab 0.333V Rogowski Coils Datasheet
- Magnelab 5 Amp Rogowski Coils Datasheet
- Magnelab stock and pricing
Other Magnelab Products
Input Range Model /Core Type |
Opening Size |
Output Type |
Output |
Hz |
ACT Current Sensors |
||||
Sense current by transforming AC input from 100 to 2400 amps to an output of 1 or 5 amps | ||||
ACT-XXXX Split 100 – 2400 amps |
0.94 – 5.55 in. | Current | 1 or 5 amps | 50 or 60 Hz |
CCT Current Sensors |
||||
Sense current by transforming AC input from 100 to 600 amps to an output of 5 amps | ||||
CCT-1200 Solid 100 – 600 amps | 1.2 in. | Current | 5 amps | 50 or 60 Hz |
DCT Voltage Sensors |
||||
Sense current by transforming AC input from 5 to 500 amps to an output of 5 or 10 Vdc at rated current | ||||
DCT-XXXX Split 5 – 500 amps | 0.4 – 1.42 in. | Voltage | 5 or 10 Vdc | 50 or 60 Hz |
DVT Voltage/Current Transducers |
||||
Output voltage proportional to the DC input voltage. | ||||
DVT-1000 Din-Rail 100 or 1000 Vdc N/A | Voltage/Current | 1/5 Vdc or 4-20 mA | 0 Hz | |
HCT Hall Effect Split Core Current Sensors |
||||
Sense DC current up to 500 amps to a 4 Vdc or Vac output | ||||
HCT-XXXX Split 5 – 500 amps | 0.4 – 1.42 in. | Voltage | 4 Vdc or 4 Vac | 0 to 167 KHz |
HFCT High Frequency Current Transformers |
||||
Broad frequency response CT’s, operate from 0.5 Hz to 500 MHz | ||||
HFCT Solid Toroid 200 – 20,000 amps DC .25 – 2 in. or 2 – 71 amps AC | Voltage | 0.025 to 5.0 V/A | 0.5 Hz to 500 MHz | |
HT Hall Effect Solid Core Current Sensors |
||||
Sense DC current up to 800 amps to an output of 100 to 250 mA Vdc or Vac | ||||
HT-XXXM Solid 200 – 800 amps 1 – 1.7 in. | Current | 100 to 250 mA | 0 to 125 KHz | |
ICT Split Core Current Transformers |
||||
Sense AC current up to 1,600 amps to an output of 5 amps | ||||
ICT-2000 Split 400 – 1600 amps 2 in. | Current | 5 amps | 50 to 400 Hz | |
MAG RMS Voltage Transducers |
||||
Sense AC current 0.333 volts to an output of 0.5 to 5 amps | ||||
MAG-RMS-333 Box 0.333 Vac N/A | Voltage | 0.5 to 5 Vdc | 40 to 400 Hz |
Model | Hz |
MCT Split Core Current Sensors |
|
Sense AC current up to 250 amps to an output of 4-20 mA | |
MCT-XXXX Split 10 – 250 amps 0.63 – 1 in. Current 4 to 20 mA | 50 or 60 Hz |
MGC Solid Core Current Sensors |
|
Sense AC current up to 300 amps to an output of 5 amps | |
MGC-1000 Solid Toroid 30 – 300 amps 1 in. Current 5 amps | 50 to 400 Hz |
MGS Split Core Flexible Rogowski Coil Systems |
|
Three-phase flexible Rope CT’s and integrator sense AC current up to 5000 amps to a 4-20 mA output (comes with three coils and an integrator) | |
MGS-1800 Flexible/Split 250 – 5000 amps 5.7 – 14.6 in. Current 4 to 20 mA | 40 to 3000 Hz |
MGT RMS Measurement Current Transducers |
|
Convert AC signals of between 0 to 333 mV to a 4-20 mA output with 0.3% accuracy | |
MGT-0420 Box 0.333 Vac N/A Current 4 to 20 mA | 40 to 3000 Hz |
RCS Flexible Rogowski Coil Systems |
|
Three-phase flexible Rope CT’s and integrator sense AC current up to 5000 amps (comes with three coils, one integrator, and power supply) | |
RCS-XXXX Flexible/Split 250 – 5000 amps 5.7 – 14.6 in. Voltage 0.333 Vac up to 5 Vac | 14.5 KHz |
RCT Flexible Rogowski Coils |
|
Single-phase flexible Rope CT’s sense AC current up to 5000 amps with an output of 0.333 Vac and standard 0.5% linearity accuracy | |
RCT-XXXX Flexible/Split 250 – 5000 amps 5.7 – 14.6 in. Voltage 0.333 Vac | 14.5 KHz |
RGS Revenue Grade Split Core Current Sensor Systems |
|
Three-phase split coil CT’s and integrator sense AC current from 5 amps to 150 amps and linearity accuracy of 0.2% (comes with three CT’s and integrator) | |
RGS-0750 Split 5 – 150 amps 0.75 in. Voltage 0.333 Vac | 50 or 60 Hz |
SCT Split Core Voltage Sensors |
|
Sense AC current from 20 to 3000 amps to an output of 0.333 Vac (available with revenue grade accuracy, hinged, wired, and wireless options) | |
SCT-XXXX Split 20 – 3000 amps 0.40 – 3 in. Voltage 0.333 Vac | 40 to 400 Hz |
SPT Current Voltage Transformers |
|
Sense DC current from 115 to 460 Vac to an output of 0.333 Vac | |
SPT-0375 Box 115 – 460 Vac N/A Voltage 0.333 Vac | 20 to 400 Hz |
UCT Solid Core Voltage Sensors |
|
Sense AC current from 5 to 400 amps to an output of 0.333 Vac with high accuracy | |
UCT-XXXX Solid Toroid 5 – 400 amps 0.30 – 1.25 in. Voltage 0.333 Vac | 30 to 1000 Hz |
Contact us for further Information