Official Magnelab Australia Distributor

Magnelab serves the energy monitoring industry with a standard line of precision current transformers. These include the flexible RopeCT® (Rogowski coil), split-core ‘opening type’ current transformers, ‘non-opening type’ toroidal current sensors, and precision potential transformers.

Magnelab offer the best of both worlds — quick turn-around of smaller quantities, as well as larger volume competitive pricing. Their offshore advantages include the lowest labor costs in the Western hemisphere, making their pricing competitive with suppliers anywhere!

Magnelab is an ISO 9001:2008 certified company, maintaining our tradition of quality and continual process improvement.

 

Other Magnelab Products

Input Range  Model /Core Type 

Opening Size 

Output Type 

Output   

Hz

ACT Current Sensors  

       
Sense current by transforming AC input from 100 to 2400 amps to an output of 1 or 5 amps         

ACT-XXXX    Split  100 – 2400 amps  

0.94 – 5.55 in.  Current   1 or 5 amps   50 or 60 Hz

CCT Current Sensors 

       
Sense current by transforming AC input from 100 to 600 amps to an output of 5 amps         
CCT-1200    Solid  100 – 600 amps   1.2 in.   Current   5 amps    50 or 60 Hz

DCT Voltage Sensors 

       
Sense current by transforming AC input from 5 to 500 amps to an output of 5 or 10 Vdc at rated current         
DCT-XXXX    Split  5 – 500 amps   0.4 – 1.42 in.  Voltage   5 or 10 Vdc   50 or 60 Hz

DVT Voltage/Current Transducers 

       
Output voltage proportional to the DC input voltage.         
DVT-1000    Din-Rail  100 or 1000 Vdc  N/A     Voltage/Current  1/5 Vdc or 4-20 mA  0 Hz

HCT Hall Effect Split Core Current Sensors 

       
Sense DC current up to 500 amps to a 4 Vdc or Vac output         
HCT-XXXX    Split  5 – 500 amps   0.4 – 1.42 in.  Voltage   4 Vdc or 4 Vac   0 to 167 KHz

HFCT High Frequency Current Transformers 

       
Broad frequency response CT’s, operate from 0.5 Hz to 500 MHz         
HFCT     Solid Toroid 200 – 20,000 amps DC .25 – 2 in. or 2 – 71 amps AC    Voltage   0.025 to 5.0 V/A   0.5 Hz to 500 MHz

HT Hall Effect Solid Core Current Sensors 

       
Sense DC current up to 800 amps to an output of 100 to 250 mA Vdc or Vac         
HT-XXXM    Solid  200 – 800 amps  1 – 1.7 in.    Current   100 to 250 mA   0 to 125 KHz

ICT Split Core Current Transformers 

       
Sense AC current up to 1,600 amps to an output of 5 amps         
ICT-2000     Split  400 – 1600 amps  2 in.     Current   5 amps    50 to 400 Hz

MAG RMS Voltage Transducers 

       
Sense AC current 0.333 volts to an output of 0.5 to 5 amps         
MAG-RMS-333    Box  0.333 Vac  N/A     Voltage   0.5 to 5 Vdc   40 to 400 Hz

 

Model      Hz

MCT Split Core Current Sensors 

 
Sense AC current up to 250 amps to an output of 4-20 mA   
MCT-XXXX    Split  10 – 250 amps  0.63 – 1 in. Current  4 to 20 mA   50 or 60 Hz

MGC Solid Core Current Sensors 

 
Sense AC current up to 300 amps to an output of 5 amps   
MGC-1000    Solid Toroid 30 – 300 amps  1 in.  Current  5 amps    50 to 400 Hz

MGS Split Core Flexible Rogowski Coil Systems 

 
Three-phase flexible Rope CT’s and integrator sense AC current up to 5000 amps to a 4-20 mA output (comes with three coils and an integrator)   
MGS-1800    Flexible/Split 250 – 5000 amps  5.7 – 14.6 in. Current  4 to 20 mA   40 to 3000 Hz

MGT RMS Measurement Current Transducers 

 
Convert AC signals of between 0 to 333 mV to a 4-20 mA output with 0.3% accuracy   
MGT-0420    Box  0.333 Vac  N/A  Current  4 to 20 mA   40 to 3000 Hz

RCS Flexible Rogowski Coil Systems 

 
Three-phase flexible Rope CT’s and integrator sense AC current up to 5000 amps (comes with three coils, one integrator, and power supply)   
RCS-XXXX    Flexible/Split 250 – 5000 amps  5.7 – 14.6 in. Voltage  0.333 Vac up to 5 Vac  14.5 KHz

RCT Flexible Rogowski Coils  

 
Single-phase flexible Rope CT’s sense AC current up to 5000 amps with an output of 0.333 Vac and standard 0.5% linearity accuracy    
RCT-XXXX    Flexible/Split 250 – 5000 amps  5.7 – 14.6 in. Voltage  0.333 Vac   14.5 KHz

RGS Revenue Grade Split Core Current Sensor Systems 

 
Three-phase split coil CT’s and integrator sense AC current from 5 amps to 150 amps and linearity accuracy of 0.2% (comes with three CT’s and integrator)   
RGS-0750    Split  5 – 150 amps  0.75 in.  Voltage  0.333 Vac   50 or 60 Hz

SCT Split Core Voltage Sensors 

 
Sense AC current from 20 to 3000 amps to an output of 0.333 Vac (available with revenue grade accuracy, hinged, wired, and wireless options)   
SCT-XXXX    Split  20 – 3000 amps  0.40 – 3 in. Voltage  0.333 Vac   40 to 400 Hz

SPT Current Voltage Transformers 

 
Sense DC current from 115 to 460 Vac to an output of 0.333 Vac    
SPT-0375    Box  115 – 460 Vac  N/A  Voltage  0.333 Vac   20 to 400 Hz

UCT Solid Core Voltage Sensors 

 
Sense AC current from 5 to 400 amps to an output of 0.333 Vac with high accuracy   
UCT-XXXX    Solid Toroid 5 – 400 amps  0.30 – 1.25 in. Voltage  0.333 Vac   30 to 1000 Hz

 

    Contact us for further Information