  • DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    36 pcs in stock

    LEM DVL 2000 Series Closed Loop AC/DC Digital Voltage Transducer 2000V Input, 50mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    36 pcs in stock

    $565.00
    $666.70 inclGST

  • Last stock! DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    4 pcs in stock

    LEM DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 500V Measurement Range +/- 750V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    4 pcs in stock

    $551.00
    $650.18 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 500 UI, Digital Voltage Transducer 500V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    9 pcs in stock

    LEM DVL 500 UI, Digital Voltage Transducer 500V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 500 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 500V Measurement Range +/- 750V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    9 pcs in stock

    $661.00
    $779.98 inclGST

  • Last stock! LEM International SA AC/DC Voltage Hall Effect Sensor DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 50mA output, 12kV Isolation FE-DVM 2000

    DVM 2000-UI Digital Voltage Transducer, Vpn = 2000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation

    5 pcs in stock

    EM DVM 2000-UI Digital Voltage Transducer, Vpn = 2000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation Features Bandwidth DC to 13kHz 4-20mA Unipolar Analogue Output Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 2000-UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage 24 VDC, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 4 mA at 0V, to 20mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $1,238.00
    $1,460.84 inclGST

  • Last stock! LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 1000 UI, Digital Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    1 pcs in stock

    LEM DVL 1000 UI Digital Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1000 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    1 pcs in stock

    $649.80
    $766.76 inclGST

  • DVL 1500/SP5, Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, All Terminals From the Side, No Top Terminals DVL 1500/SP5, Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, All Terminals From the Side, No Top Terminals

    DVL 1500/SP5, Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, All Terminals From the Side, No Top Terminals

    28 pcs in stock

    LEM DVL 1500/SP5, Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, All Terminals From the Side, No Top Terminals Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 All Terminals From the Side, No Top Terminals Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1500/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Threaded inserts output, Short input studs Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    28 pcs in stock

    $965.00
    $1,138.70 inclGST

  • DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 6400 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 6400V Measurement Range +/- 9500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $2,806.00
    $3,311.08 inclGST

  • DV 4200/SP4,  Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 4200/SP4, Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 4200/SP4,  Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 4200/SP4 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4200V Measurement Range +/- 6000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,642.00
    $1,937.56 inclGST

  • DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation, SP3 has extra long thread terminals Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 4200/SP3 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4200V Measurement Range +/- 6000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,642.00
    $1,937.56 inclGST

  • DV 3000/SP1 Digital Voltage Transducer, Vpn = 3000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 3000/SP1 Digital Voltage Transducer, Vpn = 3000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 3000/SP1 Digital Voltage Transducer, Vpn = 3000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 3000/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 3000V Measurement Range +/- 4500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,642.00
    $1,937.56 inclGST

  • DV 2800/SP4 Digital Voltage Transducer, Vpn = 2800V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 2800/SP4 Digital Voltage Transducer, Vpn = 2800V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 2800/SP4 Digital Voltage Transducer, Vpn = 2800V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 2800/SP4 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2800V Measurement Range +/- 4200V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,642.00
    $1,937.56 inclGST

  • DV 2000/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 2000/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 2000/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 2000/SP2 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,564.00
    $1,845.52 inclGST