  • THST18244D-24-5000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-5000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only THST18244D-24-5000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-5000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only

    THST18244D-24-5000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-5000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST18244D-24-5000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 5000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-5000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-5000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-5000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $855.00
    $1,008.90 inclGST

  • THST18244D-24-3000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-3000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only THST18244D-24-3000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-3000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only

    THST18244D-24-3000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-3000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST18244D-24-3000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 3000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-3000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-3000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-3000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $855.00
    $1,008.90 inclGST

  • THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only

    THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-2000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $855.00
    $1,008.90 inclGST

  • THST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only THST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only

    THST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $855.00
    $1,008.90 inclGST

  • THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $655.00
    $772.90 inclGST

  • THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $655.00
    $772.90 inclGST

  • THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $655.00
    $772.90 inclGST

  • THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-850 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-850-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-850 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $655.00
    $772.90 inclGST

  • THST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply THST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    THST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-600 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-600-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-600 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $655.00
    $772.90 inclGST

  • THST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply THST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    THST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    THST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-500 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $655.00
    $772.90 inclGST

  • H-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply

    H-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    H-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-500 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-500-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $495.00
    $584.10 inclGST

  • H-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply

    H-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply

    Out of stock

    Free Aus Post Shipping for $300 Spend

    H-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-400 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-400-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-400 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $495.00
    $584.10 inclGST