Moulded Case Circuit Breakers (MCCB)
-
ROT-FGM6-250, Extended Rotary Handle for 3 POLE MCCB FGM6-250 Frame Size
Trent ROT-FGM6-250, Extended Rotary Handle for 3 POLE MCCB FGM6-250 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP SuDirect access to push to trip button with rotary handle mounted Datasheet Product Datasheet
$52.00
$61.36 inclGST -
ROT-FGM6DC-320, Extended Rotary Handle for 3 POLE DC MCCB FGM6DC-320 Frame Size
Trent ROT-FGM6DC-320, Extended Rotary Handle for 3 POLE DC MCCB FGM6DC-320 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on DC MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP SuDirect access to push to trip button with rotary handle mounted Datasheet Product Datasheet
$72.00
$84.96 inclGST -
MOD2 3NL 250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 27kA 250 Amp, 400/690VAC
Free Aus Post Shipping for $300 SpendIskra Doo MOD2 3NL 250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 27kA 250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MOD2 3NL 250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current Icu = 36kA, Ics = 27kA, @ 400VAC, Icu =20kA @ 690VAC Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
MOD1 3NL 40A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 18kA, 40 Amp, 400/690VAC
Free Aus Post Shipping for $300 SpendIskra Doo MOD1 3NL 40A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 18kA, 40 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 3 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MOD1 3NL 40A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 40 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current Icu = 36kA, Ics = 18kA @ 400VAC, Ics = 20kA @ 690VAC Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6250OF11R, 230VAC 6 Amp Auxiliary Contact 1NO + 1NC for, Right Side Mount Moulded Case Circuit Breaker (MCCB) FGM6S Body Size 250
Trent FGM6250OF11R, 230VAC 6 Amp Auxiliary Contact 1NO + 1NC for, Right Side Mount Moulded Case Circuit Breaker (MCCB) FGM6S Body Size 250 Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Auxiliary Contact, Right Side Mount UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6250OF11R Functions Auxiliary Contact DC MCCB Operating Temperature -25 to 50 Deg C Configuration 1NO + 1NC Insulation Voltage 800V Mounting Right Side Mount Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$25.00
$29.50 inclGST -
TC-FGM6S-3P-630, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY
Trent TC-FGM6S-3P-630, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-3P-630 Functions 3 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$15.00
$17.70 inclGST -
ROT-FGM6DC-320-2, Extended Rotary Handle for 2 POLE DC MCCB FGM6DC-320 Frame Size
Trent ROT-FGM6DC-320-2, Extended Rotary Handle for 2 POLE DC MCCB FGM6DC-320 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on DC MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP SuDirect access to push to trip button with rotary handle mounted Datasheet Product Datasheet
$72.00
$84.96 inclGST -
ROT-FGM6DC-400-2, Extended Rotary Handle for 2 POLE DC MCCB FGM6DC-400,630,800 Frame Size
Trent ROT-FGM6DC-400-2, Extended Rotary Handle for 2 POLE DC MCCB FGM6DC-400,630,800 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on DC MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP Direct access to push to trip button with rotary handle mounted Datasheet Product Datasheet
$82.30
$97.11 inclGST -
FGM6-3P-1250M 1000A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1000 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1250M 1000A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1000 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1250M 1000A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1000 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6-3P-1250M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1250 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1250M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1250M 1250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6-3P-1600M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1250 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1600M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1600M 1250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6-3P-1600M 1600A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1600 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1600M 1600A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1600 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1600M 1600A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1600 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet