We are stocking a limited range of monitoring relays based on market demand. If you are interested in any products we do not have in stock please contact us

Monitoring Relays

Filter
View
Showing all 2 Items
$210.60+GST $234.00+GST
20pcs in stock , more available on 4-6 Weeks
Quick View {"id":2014108909683,"title":"84874320 Single Phase C-Lynx Speed Monitoring\/Control Relay With SP-NO\/NC Contacts, 24 - 240 V AC\/DC","handle":"84874320","description":"\u003ch3\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eCrouzet HSV\u003c\/strong\u003e Speed Monitoring\/Control Relay With SP-NO\/NC Contacts\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: #3d85c6;\"\u003eDIN Rail Mount 35 mm HSV Part number 84874320 :\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControl of overspeed, underspeed, operating rate, stopping\u003c\/li\u003e\n\u003cli\u003eMeasurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type\u003c\/li\u003e\n\u003cli\u003eWorks with either NO or NC sensors\u003c\/li\u003e\n\u003cli\u003eTime between pulses adjustable from 0.05 s to 10 min.\u003c\/li\u003e\n\u003cli\u003ePower-on inhibit time, adjustable from 0.6 to 60 s Inhibit time can be managed via an external contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84874320 (Single Phase C-Lynx Speed Monitoring Relay With SP-NO\/NC Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpeed Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 → 240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eInhibit Delay Timing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 \u003cspan\u003e→ 60s (0, +10% of full scale)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eThreshold Crossing Response\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e15ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time (Memory Mode)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time (Power Break)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eRepetition Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eThreshold Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 → 100 % of the range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807608\/Crouzet%20Automation\/Datasheets\/monitoring-relays-speed-monitoring-relays-din-rail-mount-35-mm-hsv-Part_number-84874320.pdf\" target=\"_blank\" title=\"Crouzet Automation 848744320 Speed Monitoring Relay\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-04-07T21:43:47+10:00","created_at":"2019-03-31T14:07:17+11:00","vendor":"Crouzet Automation","type":"Monitoring Relay","tags":["Availability_10+ pcs","Availability_In Stock","Contacts_DPDT","Load_Single Phase","Supply Voltage_24-240VAC","Type_Speed Monitoring Relay"],"price":21060,"price_min":21060,"price_max":21060,"available":true,"price_varies":false,"compare_at_price":23400,"compare_at_price_min":23400,"compare_at_price_max":23400,"compare_at_price_varies":false,"variants":[{"id":18422768074867,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-84874320","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"84874320 Single Phase C-Lynx Speed Monitoring\/Control Relay With SP-NO\/NC Contacts, 24 - 240 V AC\/DC","public_title":null,"options":["Default Title"],"price":21060,"weight":300,"compare_at_price":23400,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/84874320.jpg?v=1554184688"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/84874320.jpg?v=1554184688","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eCrouzet HSV\u003c\/strong\u003e Speed Monitoring\/Control Relay With SP-NO\/NC Contacts\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: #3d85c6;\"\u003eDIN Rail Mount 35 mm HSV Part number 84874320 :\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControl of overspeed, underspeed, operating rate, stopping\u003c\/li\u003e\n\u003cli\u003eMeasurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type\u003c\/li\u003e\n\u003cli\u003eWorks with either NO or NC sensors\u003c\/li\u003e\n\u003cli\u003eTime between pulses adjustable from 0.05 s to 10 min.\u003c\/li\u003e\n\u003cli\u003ePower-on inhibit time, adjustable from 0.6 to 60 s Inhibit time can be managed via an external contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84874320 (Single Phase C-Lynx Speed Monitoring Relay With SP-NO\/NC Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpeed Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 → 240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eInhibit Delay Timing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 \u003cspan\u003e→ 60s (0, +10% of full scale)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eThreshold Crossing Response\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e15ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time (Memory Mode)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time (Power Break)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eRepetition Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eThreshold Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 → 100 % of the range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807608\/Crouzet%20Automation\/Datasheets\/monitoring-relays-speed-monitoring-relays-din-rail-mount-35-mm-hsv-Part_number-84874320.pdf\" target=\"_blank\" title=\"Crouzet Automation 848744320 Speed Monitoring Relay\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$201.60+GST $224.00+GST
20pcs in stock , more available on 4-6 Weeks
Quick View {"id":2014108876915,"title":"84873220 3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts, 3 x 220 - 480 V AC H3US","handle":"84873220","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet H3US 3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eH3US and M3US relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eThe H3USN relay controls, on 3-phase networks :\u003c\/li\u003e\n\u003cli\u003eOvervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eLoss of neutral\u003c\/li\u003e\n\u003cli\u003eMulti-voltage Products\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral (H3USN only) Measurements are taken between Phases for the H3US \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eM3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873220 (3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807531\/Crouzet%20Automation\/Datasheets\/H3US.pdf\" target=\"_blank\" title=\"Crouzet Automation 84873220 Datasheet\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003ctable style=\"width: 29.4011%; float: left;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%; text-align: right;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%; text-align: right;\"\u003e\u003cstrong\u003eLegend\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eHysteresis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003ePhases L1, L2, L3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"panel-heading\" style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"panel-body\" style=\"text-align: right;\"\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/CO_RMC2_H3US_N_N1_large.jpg?v=1560665492\" alt=\"84873220 Application Note\" width=\"312\" height=\"166\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe relay monitors its own supply voltage. It controls :  \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from + 2 to +20 %  (+2 to +10 %  over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls :   \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %.  Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-04-07T22:09:40+10:00","created_at":"2019-03-31T14:06:53+11:00","vendor":"Crouzet Automation","type":"Monitoring Relay","tags":["Availability_10+ pcs","Availability_In Stock","Contacts_DPDT","Load_3 Phase","Supply Voltage_220-480VAC","Type_Voltage Monitoring Relay"],"price":20160,"price_min":20160,"price_max":20160,"available":true,"price_varies":false,"compare_at_price":22400,"compare_at_price_min":22400,"compare_at_price_max":22400,"compare_at_price_varies":false,"variants":[{"id":18422767550579,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-84873220","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"84873220 3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts, 3 x 220 - 480 V AC H3US","public_title":null,"options":["Default Title"],"price":20160,"weight":300,"compare_at_price":22400,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/84871120.jpg?v=1554184688"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/84871120.jpg?v=1554184688","options":["Title"],"content":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet H3US 3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eH3US and M3US relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eThe H3USN relay controls, on 3-phase networks :\u003c\/li\u003e\n\u003cli\u003eOvervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eLoss of neutral\u003c\/li\u003e\n\u003cli\u003eMulti-voltage Products\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral (H3USN only) Measurements are taken between Phases for the H3US \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eM3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873220 (3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807531\/Crouzet%20Automation\/Datasheets\/H3US.pdf\" target=\"_blank\" title=\"Crouzet Automation 84873220 Datasheet\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003ctable style=\"width: 29.4011%; float: left;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%; text-align: right;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%; text-align: right;\"\u003e\u003cstrong\u003eLegend\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eHysteresis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003ePhases L1, L2, L3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"panel-heading\" style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"panel-body\" style=\"text-align: right;\"\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/CO_RMC2_H3US_N_N1_large.jpg?v=1560665492\" alt=\"84873220 Application Note\" width=\"312\" height=\"166\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe relay monitors its own supply voltage. It controls :  \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from + 2 to +20 %  (+2 to +10 %  over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls :   \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %.  Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e"}