Motor Protection Breakers & Motor Start Relays

56 products

  • Last stock! 4CR-1-743, AC Motor Start Relay, 18.9 Amp Max Pickup Current, 15.6 Amp Minimum Drop Out Current 4CR-1-743, AC Motor Start Relay, 18.9 Amp Max Pickup Current, 15.6 Amp Minimum Drop Out Current

    4CR-1-743, AC Motor Start Relay, 18.9 Amp Max Pickup Current, 15.6 Amp Minimum Drop Out Current

    3 pcs in stock

    Klixon - Sensata 4CR-1-743, AC Motor Start Relay, 18.9 Amp Max Pickup Current, 15.6 Amp Minimum Drop Out Current Klixon 4CR Current Type Motor starting relay is a compact, high capacity relay, designed for universal application to split phase and capacitor start, single phase motors with start-winding currents up to 25 Amperes. Features : Reliable Operation and long life Wide Range of Pickup and drop out ratings Start-winding Rating - 25 Amps Small size for installation in compact equipment Economical Specification Iskra Doo Part Number 4CR-1-743 Functions Splitphase Motor Start Relay Nominal Current Range 15.6 - 18.9 Amp RMS Weight 70g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes How to Test 4CR Relays - Blog

    3 pcs in stock

    $65.00
    $76.70 inclGST

  • MST-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range FE-MS-25-20

    MST-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal Release Only

    6 pcs in stock

    Iskra Doo MST-25-20, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 16 - 20 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    6 pcs in stock

    $89.75
    $105.91 inclGST

  • MS-25-2.5, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-2.5, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal and Magnetic Release

    10 pcs in stock

    Iskra Doo MS-25-2.5, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-2.5 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1.6 - 2.5 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    10 pcs in stock

    $75.00
    $88.50 inclGST

  • Last stock!

    MS-25-U380-415, Undervoltage Release for MS and MST Series Motor Protection Switch, 380VAC - 415VAC Nominal

    2 pcs in stock

    Iskra Doo MS-25-U380-415, Undervoltage Release for MS and MST Series Motor Protection Switch, 380VAC - 415VAC Nominal Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-U380-415 Functions Undervoltage release for 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @400VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    2 pcs in stock

    $39.80
    $46.96 inclGST

  • MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range FE-MS-25-20

    MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Free Aus Post Shipping for $300 spend

    Iskra Doo MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 16 - 20 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series 

    Out of stock

    Free Aus Post Shipping for $300 spend

    $78.00
    $92.04 inclGST

  • MST-25-4, Motor Protection Switch, 3 Phase, 690VAC, 2.5 - 4 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-4, Motor Protection Switch, 3 Phase, 690VAC, 2.5 - 4 Amp Setting Range, Thermal Release Only

    10 pcs in stock

    Iskra Doo MST-25-4, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-4 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.5 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    10 pcs in stock

    $89.75
    $105.91 inclGST

  • MS-25-1, Motor Protection Switch, 3 Phase, 690VAC, 0.63 - 1 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-1, Motor Protection Switch, 3 Phase, 690VAC, 0.63 - 1 Amp Setting Range, Thermal and Magnetic Release

    17 pcs in stock

    Iskra Doo MS-25-1, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-1 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.63 - 1 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    17 pcs in stock

    $75.00
    $88.50 inclGST

  • MST-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range, Thermal Release Only MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range - Fastron Electronics Store

    MST-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range, Thermal Release Only

    10 pcs in stock

    Iskra Doo MST-25-16, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breakign Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-16 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 10 - 16 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    10 pcs in stock

    $89.85
    $106.02 inclGST

  • MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    19 pcs in stock

    Iskra Doo MS-25-6.3, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-6.3 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    19 pcs in stock

    $75.00
    $88.50 inclGST

  • MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range, Thermal and Magnetic Release MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range - Fastron Electronics Store

    MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MS-25-16, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-16 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 10 - 16 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $77.00
    $90.86 inclGST

  • PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    Out of stock

    Free Aus Post Shipping for $300 spend

    Iskra Doo PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number PS11 Functions Auxiliary Contact for 3 Phase Motor Protection Switch, 1 x NO 6 Amp @ 230VAC, 1 x NC 6 Amp @ 230VAC Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @230VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 spend

    $18.00
    $21.24 inclGST

  • 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current

    4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current

    10 pcs in stock

    Sensata 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current Klixon 4CR Current Type Motor starting relay is a compact, high capacity relay, designed for universal application to split phase and capacitor start, single phase motors with start-winding currents up to 25 Amperes. Features : Reliable Operation and long life Wide Range of Pickup and drop out ratings Start-winding Rating - 25 Amps Small size for installation in compact equipment Economical Specification Iskra Doo Part Number 4CR-1-770 Functions Splitphase Motor Start Relay Nominal Current Range 20.6 - 25 Amp RMS Weight 70g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes How to Test 4CR Relays - Blog

    10 pcs in stock

    $85.00
    $100.30 inclGST

  • FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release

    56 pcs in stock

    Trent FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 28 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 13 - 18 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    56 pcs in stock

    $68.00
    $80.24 inclGST

  • FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M08 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.3 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    59 pcs in stock

    $62.00
    $73.16 inclGST

  • FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives  

    59 pcs in stock

    $62.00
    $73.16 inclGST

  • MST-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range FE-MS-25-10

    MST-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal Release Only

    10 pcs in stock

    Iskra Doo MST-25-10, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers anre a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 6 - 10 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    10 pcs in stock

    $89.75
    $105.91 inclGST

  • Last stock! MS32-4, Motor Protection Switch, 3 Phase, 690VAC, 2.5 - 4 Amp Setting Range, Thermal Release Only

    MS32-4, Motor Protection Switch, 3 Phase, 690VAC, 2.5 - 4 Amp Setting Range, Thermal Release Only

    4 pcs in stock

    Iskra Doo MS32-4, Motor Protection Switch, 3 Phase, 690VAC, 2.5 - 4 Amp Setting Range, Thermal & Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal & Magnetic release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-4 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.5 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    4 pcs in stock

    $186.00
    $219.48 inclGST

  • Last stock! MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage

    MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage

    5 pcs in stock

    Iskra Doo MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-A220-240 Functions Shunt Trip release for 3 Phase Motor Protection Switch Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @400VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    5 pcs in stock

    $39.80
    $46.96 inclGST

  • 4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current 4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current

    4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current

    74 pcs in stock

    Sensata 4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current Klixon 4CR Current Type Motor starting relay is a compact, high capacity relay, designed for universal application to split phase and capacitor start, single phase motors with start-winding currents up to 25 Amperes. Features : Reliable Operation and long life Wide Range of Pickup and drop out ratings Start-winding Rating - 25 Amps Small size for installation in compact equipment Economical Specification Iskra Doo Part Number 4CR-1-645 Functions Splitphase Motor Start Relay Nominal Current Range 3.8 - 4.55 Amp RMS Weight 70g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes How to Test 4CR Relays - Blog

    74 pcs in stock

    $65.00
    $76.70 inclGST

  • FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    120 pcs in stock

    Trent FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M21 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 17 - 23 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    120 pcs in stock

    $68.00
    $80.24 inclGST

  • FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp

    FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp

    Out of stock

    Trent FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN20 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $12.00
    $14.16 inclGST

  • FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp

    FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp

    233 pcs in stock

    Trent FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN11 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    233 pcs in stock

    $12.00
    $14.16 inclGST

  • FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp

    FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp

    200 pcs in stock

    Trent FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU400 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 385-415VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    200 pcs in stock

    $12.00
    $14.16 inclGST

  • FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp

    FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp

    Out of stock

    Trent FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU225 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 220-240VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $12.00
    $14.16 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account