LEM ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%
Features
125 Amp AC Current Measurement
Signal Conditioned output
Split Core
4-20mA Current Output
Cable or Din Rail Mounting
20-28VDC Powered
Isolated plastic case recognised according to UL94-V0
UL508 Rated
Advantages
Large aperture for cable up to ? 10mm
High isolation between primary and secondary circuits
Easy installation
Applications
Hybrid Inverter
Power Metering
Power Quality Analysis
Distributed Measurement Systems
Current Measurement
Energy Management
Motor Control
Condition Monitoring
Specification
LEM Part Number
ATO-5-B420-D10-SP4
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
125 Amp
Output
4-20mA (Average RMS)
Isolation
4.3kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount or Cable Mount
Operating Temperature Range
-10°C / 55°C
Accuracy
1.5%
Termination Style
4M Output Cable
Unit Weight
140g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS521-SD-420E)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output
Features
Average RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FD-420E
Technology
Solid Core Solid Core AC Current Transducer
Range
0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
4-20mA Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS2151-SD-V10)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
Average RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FD-V10
Technology
Solid Core Solid Core AC Current Transducer
Range
0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 200 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
LEM HAZ 4000-SB, O/L Hall Effect Current Transducer, 4000A, +/-10V Instant Output, +/-15V supply
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
Features
Instantaneous output version +/-10V, +/-20mA
True RMS output versions 4-20mA, 0-10V putput
Hall effect measuring principle
Galvanic isolation between primary and secondary circuit
Instantaneous voltage output
Isolation voltage 17kV Rms /50 Hz /1min
Low power consumption
Package in PBT meeting UL 94-V0
Instantaneous voltage output
Advantages
Easy installation
Small size and space savings
Only one design for wide current ratings range
High immunity against external interference
Applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding and telecom applications
Application domain
Industrial
Traction
Specification
LEM Part Number
HAZ 4000-SB
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
+/- 15VDC
Load Current (RMS + DC)
4000 Amp
Overload Rating
30000 At
Output
+/-10 V Instantaneous
Isolation
17kV (AC, 50Hz, 1 min)
Bandwidth
DC-3kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
F2023A (FUJICON)
Unit Weight
6kg
Factory Pack Qty
2
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron FES2151-FP-V10, Split Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy FCS2151-SP-V10
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
Average RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FD-V10
Technology
Solid Core Split Core AC Current Transducer
Range
0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 200 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS521-SD-V10)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
Average RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FD-V10
Technology
Solid Core Solid Core AC Current Transducer
Range
0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
LEM HAZ 6000-SB, Hall Effect Current Transducer, 6000A, +/-10V Instant Output, +/-15V supply
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
Features
Instantaneous output version +/-10V, +/-20mA
True RMS output versions 4-20mA, 0-10V putput
Hall effect measuring principle
Galvanic isolation between primary and secondary circuit
Instantaneous voltage output
Isolation voltage 17kV Rms /50 Hz /1min
Low power consumption
Package in PBT meeting UL 94-V0
Instantaneous voltage output
Advantages
Easy installation
Small size and space savings
Only one design for wide current ratings range
High immunity against external interference
Applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding and telecom applications
Application domain
Industrial
Traction
Specification
LEM Part Number
HAZ 6000-SB
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
+/- 15VDC
Load Current (RMS + DC)
6000 Amp
Overload Rating
30000 At
Output
+/-10 V Instantaneous
Isolation
17kV (AC, 50Hz, 1 min)
Bandwidth
DC-3kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
F2023A (FUJICON)
Unit Weight
6kg
Factory Pack Qty
2
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AHR 500 B420, Hall Effect Current Transducer, 500A, 4-20mA True RMS output, 20-50VDC supply
Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
Split Core
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Busbar mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable or busbar up to 104 x 40mm
High isolation between primary and secondary circuits
Easy installation
Applications
-AC Power Supplies or Motors
True RMS sensing - the most accurate way to monitor power supply or input power
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement.
-Renewable Energy Installations or Backup Batteries
Continuous condition monitoring allowing automatic failure detection and prediction
-Application Domain
Energy and Automation
Specification
LEM Part Number
AHR 1500 B420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Nominal Current (RMS + DC)
500 Amp
Maximum Measurement Current (Peak)
2000 Amp
Output
4-20mA
Isolation
5.8kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
650g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
AI-PMUL + ART-B22-D125-SP3
Function
Single Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Fastron FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy (FCS2151-FP-V5)
Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 0-5V True RMS output
Features
True RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FP-V5
Technology
Split Core AC Current Transducer
Range
Selectable 0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-5V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES521-FP-V10, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 0-10V Output. 1% Accuracy (FCS521-FP-V10)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
True RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FP-V10
Technology
Split Core AC Current Transducer
Range
Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy (FCS521-FP-420E)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output
Features
True RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FP-420E
Technology
Split Core AC Current Transducer
Range
Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
4-20mA Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide