Solid State Relay and Heatsink Assemblies
-
HS211 + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 70 Deg C, 60VDC Load
Crydom HS211 + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 70 Deg C, 60VDC Load Features Ratings from 3A to 7 Amp @3-60VDC SCR output Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + DC60S3 Switching Type DC Switching ROHS/CE/UL Yes Control Voltage 3.5-32VDC Load Current 3 Amp (rms) @ 40 Deg C Surge Capability 10 Amp (peak) Special Feature N/A Mounting Style Din Rail or Panel Mount Recommended Voltage Range 3-60VDC Max DC Voltage 60VDC Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 DC60 Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$66.00
$77.88 inclGST -
FDH2548ZA4 + HS211B, Panel Mount Solid State Relay, 90-280VAC Control Input, 70-480VAC Output, 21 Amps
Fastron FDH2548ZA4 + HS211B, Panel Mount Solid State Relay, 90-280VAC Control Input, 70-480VAC Output, 21 Amps Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Spec Part Number FDH2548ZA4 + HS211B Switching Type Zero Crossing Control Voltage 90-280VAC Load Current 21 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature IP20 Cover Mounting Style Panel Mount Load Voltage Range 70-480VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A FDH Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$69.20
$81.66 inclGST -
HS501DR + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 60 Deg C, 60VDC Load
Crydom HS501DR + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 60 Deg C, 60VDC Load Features Ratings from 3A to 7 Amp @3-60VDC SCR output Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + DC60S3 Switching Type DC Switching ROHS/CE/UL Yes Control Voltage 3.5-32VDC Load Current 3 Amp (rms) @ 40 Deg C Surge Capability 10 Amp (peak) Special Feature N/A Mounting Style Din Rail or Panel Mount Recommended Voltage Range 3-60VDC Max DC Voltage 60VDC Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR DC60 Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$70.20
$82.84 inclGST -
FDH2548ZD3 + HS211B, Panel Mount Solid State Relay, 3-32 Control Input, 70-480VAC Output, 21 Amps
Fastron FDH2548ZD3 + HS211B, Panel Mount Solid State Relay, 3-32 Control Input, 48-480VAC Output, 21 Amp Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Spec Part Number FDH2548ZD3 + HS211B Switching Type Zero Crossing Control Voltage 3-32VDC Load Current 21 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature IP20 Cover Mounting Style Panel Mount Load Voltage Range 70-480VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A FDH Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$79.00
$93.22 inclGST -
HS501DR + D2440, Panel or Din Rail Mount Solid State Relay 3-32VDC Control Input, 24-280VAC Output, 10 Amps
Crydom HS501DR + D2440, Panel or Din Rail Mount Solid State Relay 3-32VDC Control Input, 24-280VAC Output, 10 Amps Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + D2440 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 10 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature N/A Mounting Style Din Rail or Panel Mount Load Voltage Range 24-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR Series 1 AC Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$89.00
$105.02 inclGST -
HS501DR + D2440G, Panel or Din Rail Mount Solid State Relay, 3-32VDC Control Input, LED Staus, 24-280VAC Output, 10 Amps
Crydom HS501DR + D2440G, Panel or Din Rail Mount Solid State Relay, 3-32VDC Control Input, LED Staus, 24-280VAC Output, 10 Amps Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + D2440G Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 10 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature LED Status Indicator Mounting Style Din Rail or Panel Mount Load Voltage Range 24-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR Series 1 AC Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$89.00
$105.02 inclGST -
HS301DR + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 70 Deg C, 60VDC Load
Crydom HS301DR + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 70 Deg C, 60VDC Load Ratings from 3A to 7 Amp @3-60VDC SCR output Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS301DR + DC60S3 Switching Type DC Switching ROHS/CE/UL Yes Control Voltage 3.5-32VDC Load Current 3 Amp (rms) @ 40 Deg C Surge Capability 10 Amp (peak) Special Feature N/A Mounting Style Din Rail or Panel Mount Recommended Voltage Range 3-60VDC Max DC Voltage 60VDC Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS301DR DC60 Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$95.20
$112.34 inclGST -
HS211A + CY9008, Panel Mount Solid State Relay, 3-32VDC Control Input, 48-660VAC Output, 25 Amps
Crydom HS211A + CY9008, Panel Mount Solid State Relay, 3-32VDC Control Input, 48-660VAC Output, 25 Amps Features Ratings from 25A to 125 Amp @48-660 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount only Spec Part Number HS211A + CY9008 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 23 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature N/A Mounting Style Panel Mount Load Voltage Range 48-660VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$95.20
$112.34 inclGST -
HS501DR + D2450-10 Single Phase Solid State Relay 3-32VDC Control Input, Random Crossing, LED Status Indicator, 24-280VAC Output, 10 Amps Panel or Din Rail Mount
Crydom HS501DR + D2450-10 Single Phase Solid State Relay 3-32VDC Control Input, Random Crossing, LED Status Indicator, 24-280VAC Output, 10 Amps Panel or Din Rail Mount Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + D2450-10 Switching Type Random Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 10 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature N/A Mounting Style Panel Mount Load Voltage Range 24-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR D2450-10 Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$103.30
$121.89 inclGST -
HS211 + DC60S7, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7A @ 70 Deg C, 60VDC Load
Crydom HS211 + DC60S7, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7A @ 70 Deg C, 60VDC Load Features Ratings from 3A to 7 Amp @3-60VDC SCR output Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + DC60S7 Switching Type DC Switching ROHS/CE/UL Yes Control Voltage 3.5-32VDC Load Current 7 Amp (rms) @ 40 Deg C Surge Capability 14 Amp (peak) Special Feature N/A Mounting Style Din Rail or Panel Mount Recommended Voltage Range 3-60VDC Max DC Voltage 60VDC Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 DC60 Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$105.40
$124.37 inclGST -
HS501DR + DC60S7, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7A @ 40 Deg C, 60VDC Load
Crydom HS501DR + DC60S7, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7A @ 40 Deg C, 60VDC Load Features Ratings from 3A to 7 Amp @3-60VDC SCR output Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + DC60S7 Switching Type DC Switching ROHS/CE/UL Yes Control Voltage 3.5-32VDC Load Current 6.5 Amp (rms) @ 40 Deg C Surge Capability 14 Amp (peak) Special Feature N/A Mounting Style Din Rail or Panel Mount Recommended Voltage Range 3-60VDC Max DC Voltage 60VDC Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR DC60 Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$107.70
$127.09 inclGST -
HS211 + D2425T, Panel or slide on Din Rail Solid State Relay, 3-32VDC Control Input, 24-280VAC Output, 23 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + D2425T, Panel or slide on Din Rail Solid State Relay, 3-32VDC Control Input, 24-280VAC Output, 23 Amps Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + D2425T Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Gen 3 Optocoupler Mounting Style Din Rail or Panel Mount Load Voltage Range 24-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 D2425T Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies