Power Factor Correction

130 products

  • 4C440062545A000, 440VAC L-L, 62.5kVar Smart Capacitor Bank for Reactive Power Correction-PFC Capacitor Bank-RTR Energia-Fastron Electronics Store 4C440062545A000, 440VAC L-L, 62.5kVar Smart Capacitor Bank for Reactive Power Correction-PFC Capacitor Bank-RTR Energia-Fastron Electronics Store

    Smart ONE 50kvar 400VAC, 440VAC L-L, 50kVar Smart One Capacitor Bank for Reactive Power Correction, IP21

    Out of stock

    Fastron Electronics Smart ONE 50kvar 400VAC, 440VAC L-L, 50kVar Smart One Capacitor Bank for Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty   PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps   Specification Fastron Electronics Part Number Smart ONE 50kvar 400VAC (12.5 + 16.7 + 25) Function Reactive Power Correction Steps 2 x 12.5kvar, 1 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-550VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors

    Out of stock

    $2,250.00
    $2,655.00 inclGST

  • Last stock! UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    4 pcs in stock

    Iskra Doo UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms (U)MT version = Ring type terminal block Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.1 on Comms RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number UMT540-HSHFNAAAA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 4 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations Ring Type Terminal Block Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Software MiQen Setting Software

    4 pcs in stock

    $2,099.50
    $2,477.41 inclGST

  • D5251255TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 12.5 KVAR, 525V, 50HZ, 100 x 230mm D5251255TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 12.5 KVAR, 525V, 50HZ, 100 x 230mm

    D5251255TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 12.5 KVAR, 525V, 50HZ, 100 x 230mm

    43 pcs in stock

    D5251255TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 12.5 KVAR, 525V, 50HZ, 100 x 230mm Characteristics and utility 12.5 kVar @ 525V @ 50 Hz 12.5.0kvar 12.5kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting True triple safety Overpressure disconnection system Protection by internal fuses DWCAP system (patented) internal windings Displacement Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification RTR Energia Part Number D5251255TER0000 Technology Dry Type, Low Loss, Self Healing Dimensions 100 x 230mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 12.5 Kvar Capacitance 3 x 48.12uF Tolerance On Capacitance -5% + 10% Current (In) 13.75 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES DWCAP system (Patented) internal windings Displacement YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 1.5kg Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables  

    43 pcs in stock

    $84.50
    $99.71 inclGST

  • D5252505TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 25.0 KVAR, 525V, 50HZ, 120 x 230mm D5252505TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 25.0 KVAR, 525V, 50HZ, 120 x 230mm

    D5252505TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 25.0 KVAR, 525V, 50HZ, 120 x 230mm

    72 pcs in stock

    D5252505TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 25.0 KVAR, 525V, 50HZ, 120 x 230mm Characteristics and utility 25 kVar @ 525V @ 50 Hz 25.0kvar 25kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting True triple safety Overpressure disconnection system Protection by internal fuses DWCAP system (patented) internal windings Displacement Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification RTR Energia Part Number D5252505TER0000 Technology Dry Type, Low Loss, Self Healing Dimensions 120 x 230mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 25.0 Kvar Capacitance 3 x 96.24uF Tolerance On Capacitance -5% + 10% Current (In) 27.49 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES DWCAP system (Patented) internal windings Displacement YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 3.1kg Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables  

    72 pcs in stock

    $189.00
    $223.02 inclGST

  • D5254005TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 40.0 KVAR, 525V, 50HZ, 136 x 230mm D5254005TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 40.0 KVAR, 525V, 50HZ, 136 x 230mm

    D5254005TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 40.0 KVAR, 525V, 50HZ, 136 x 230mm

    13 pcs in stock

    D5254005TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 40.0 KVAR, 525V, 50HZ, 136 x 230mm Characteristics and utility 40 kVar @ 525V @ 50 Hz 40.0kvar 40kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting True Triple safety Overpressure disconnection system Protection by internal fuses DWCAP system (patented) internal windings Displacement Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification RTR Energia Part Number D5254005TER0000 Technology Dry Type, Low Loss, Self Healing Dimensions 136 x 230mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 40.0 Kvar Capacitance Tolerance On Capacitance -5% + 10% Current 44 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES DWCAP system (Patented) internal windings Displacement YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 4.9kg Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables  

    13 pcs in stock

    $229.00
    $270.22 inclGST

  • KNK3053 10KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 165mm Dry Type, 3 x 38.5uF, Includes Discharge Resistor KNK3053 10KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 75 x 210mm Dry Type-Power Factor Correction Capacitor-Iskra Doo-Fastron Electronics Store

    KNK3053 10KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 165mm Dry Type, 3 x 38.5uF, Includes Discharge Resistor

    88 pcs in stock

    Iskra Doo KNK3053 10 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 165mm Dry Type, 3 x 38.5uF Characteristics and utility 10kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 10 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 90 x 165mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 10 Kvar Capacitance 3 x 38.5uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 7.2 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Feed Through Terminal Unit Weight 1.1kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    88 pcs in stock

    $139.00
    $164.02 inclGST

  • KNK3053 12.5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 48.1uF, Includes Discharge Resistor KNK3053 12.5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 75 x 245mm Dry Type-Power Factor Correction Capacitor-Iskra Doo-Fastron Electronics Store

    KNK3053 12.5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 48.1uF, Includes Discharge Resistor

    89 pcs in stock

    Iskra Doo KNK3053 12.5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 48.1uF Characteristics and utility 12.5kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 12.5 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 90 x 210mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 12.5 Kvar Capacitance 3 x 48.1uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 13.7 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Feed Through Terminal Unit Weight 1.4kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    89 pcs in stock

    $139.00
    $164.02 inclGST

  • KNK3053 15KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 57.7uF, Includes Discharge Resistor KNK3053 15KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type-Power Factor Correction Capacitor-Iskra Doo-Fastron Electronics Store

    KNK3053 15KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 57.7uF, Includes Discharge Resistor

    103 pcs in stock

    Iskra Systemi 15 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 57.7uF Characteristics and utility 15kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 15 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 90 x 210mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 15 Kvar Capacitance 3 x 57.7uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 16.5 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 1.5kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    103 pcs in stock

    $145.00
    $171.10 inclGST

  • KNK3053 20KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 245mm Dry Type, 3 x 77uF, Includes Discharge Resistor KNK3053 20KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 245mm Dry Type, 3 x 77uF, Includes Discharge Resistor

    KNK3053 20KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 245mm Dry Type, 3 x 77uF, Includes Discharge Resistor

    37 pcs in stock

    Iskra Doo KNK3053 20 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 245mm Dry Type, 3 x 77uF Characteristics and utility 20kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane UL 94 V0 resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 20 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 90 x 245mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 20 Kvar Capacitance 3 x 77uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 22 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 2.1kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    37 pcs in stock

    $164.00
    $193.52 inclGST

  • KNK3053 30KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type, 3 x 115.5uF, Includes Discharge Resistor KNK3053 30KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type-Power Factor Correction Capacitor-Iskra Doo-Fastron Electronics Store

    KNK3053 30KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type, 3 x 115.5uF, Includes Discharge Resistor

    141 pcs in stock

    Iskra Doo KNK3053 30 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type, 3 x 115.5uF Characteristics and utility 30kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 30 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 116 x 245mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 30 Kvar Capacitance 3 x 115.5uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 33 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 3kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    141 pcs in stock

    $249.00
    $293.82 inclGST

  • KNK3053 40 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 285mm Dry Type, 3 x 154uF, Includes Discharge Resistor KNK3053 40 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 285mm Dry Type-Power Factor Correction Capacitor-Iskra Doo-Fastron Electronics Store

    KNK3053 40 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 285mm Dry Type, 3 x 154uF, Includes Discharge Resistor

    45 pcs in stock

    Iskra Doo KNK3053 40 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 285mm Dry Type, 3 x 154uF Characteristics and utility 40kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 40 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 116 x 285mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 40 Kvar Capacitance 3 x 154uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 44 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Feed Through Terminal Unit Weight 3.6kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    45 pcs in stock

    $299.00
    $352.82 inclGST

  • KNK3053 5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type, 3 x 19.3uF, Includes Discharge Resistor KNK3053 5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type-Power Factor Correction Capacitor-Iskra Doo-Fastron Electronics Store

    KNK3053 5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type, 3 x 19.3uF, Includes Discharge Resistor

    44 pcs in stock

    Iskra Systemi KNK3053 5 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type, 3 x 19.3uF Characteristics and utility 5kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 5 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 75 x 165mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 5 Kvar Capacitance 3 x 19.3uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 5.5 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 0.9kg Factory Pack Quantity 25   Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet

    44 pcs in stock

    $85.60
    $101.01 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account