Meters & Analysers

3 Phase kWh Meters, Network Analysers, Power Quality Analysers


At Fastron Electronics, we offer a wide range of single and 3 phase kWh Meters, Network Analysers, and Power Quality Analysers. Our advanced models come with data logging functionality for up to 120 parameters, multiple relay outputs, ethernet, and analogue outputs to create a complete energy management system.

With more than four decades in the industry, you can trust our team to assist you with all your energy management and energy monitoring needs. We offer the products, services, and solutions that you require.

We stock single and 3 phase kWh Meters, Network Analysers, and Power Quality Analysers from a range of leading brands. This includes:

  • Iskra Sistemi d.d
  • Northern Design Electronics Ltd

With a wide range of shipping options and free shipping on orders over $300AUD, we make it fast and convenient to get the supplies you need. For customers based in Melbourne, we can also offer a broad range of technical support, services and solutions for your special project. Contact us today to find out more.

Filter
View
Showing 1 - 20 of 34 Items
$506.00exGST
1pc in stock , more available
Quick View {"id":4162428240006,"title":"MIPACK Iskra Meter Programmer","handle":"mipack-iskra-meter-programmer","description":"\u003ch1\u003e\u003cspan\u003eMIPACK Iskra Meter Programmer \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eUsed with SQ0214, MC Series Meters, and Multifunction Transducers\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUses Iskra MiQuen Software\u003c\/span\u003e\u003c\/p\u003e","published_at":"2019-09-29T14:11:54+10:00","created_at":"2019-09-29T14:43:43+10:00","vendor":"Fastron Electronics","type":"Communication Accessories","tags":["Availability_In Stock","Type_Programming Interface"],"price":50600,"price_min":50600,"price_max":50600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30257074602118,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MIPACK Iskra Meter Programmer","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MIPACK Iskra Meter Programmer","public_title":null,"options":["Default Title"],"price":50600,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/fastron-electronics-communication-accessories-mipack-iskra-meter-programmer-12785438621830.jpg?v=1572987841"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/fastron-electronics-communication-accessories-mipack-iskra-meter-programmer-12785438621830.jpg?v=1572987841","options":["Title"],"content":"\u003ch1\u003e\u003cspan\u003eMIPACK Iskra Meter Programmer \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eUsed with SQ0214, MC Series Meters, and Multifunction Transducers\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUses Iskra MiQuen Software\u003c\/span\u003e\u003c\/p\u003e"}
$199.70exGST
Backorder
Quick View {"id":3954678464627,"title":"WM1-6 230CWNA, DIN Rail Mount kWh Meter, 240VAC, 65 Amp, Single Phase, RS485 Comms, DIN Rail Mount","handle":"wm1-6-230cwna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-rs485-comms-din-rail-mount","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eWM1-6 230CWNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eIP50 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-09-04T10:56:03+10:00","created_at":"2019-09-04T10:56:03+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Measurement_240VAC","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ Single Phase"],"price":19970,"price_min":19970,"price_max":19970,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29562311901299,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230CWNA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230CWNA, DIN Rail Mount kWh Meter, 240VAC, 65 Amp, Single Phase, RS485 Comms, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":19970,"weight":350,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230cwna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-rs485-comms-din-rail-mount-12240753492083.png?v=1572998400"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230cwna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-rs485-comms-din-rail-mount-12240753492083.png?v=1572998400","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eWM1-6 230CWNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eIP50 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$118.30exGST
Backorder
Quick View {"id":3954673188979,"title":"WM1-6 230WPNA, DIN Rail Mount kWh Meter, 240VAC, 65 Amp, Single Phase, Pulse Output, DIN Rail Mount","handle":"wm1-6-230wpna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-rs485-comms-din-rail-mount","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003ePulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eWM1-6 230WPNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eOpitonal 1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eIP50 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-09-04T10:41:59+10:00","created_at":"2019-09-04T10:41:59+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Measurement_240VAC","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ Single Phase"],"price":11830,"price_min":11830,"price_max":11830,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29562284998771,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230WPNA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230WPNA, DIN Rail Mount kWh Meter, 240VAC, 65 Amp, Single Phase, Pulse Output, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":11830,"weight":350,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wpna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-pulse-output-din-rail-mount-12240717840499.png?v=1572998385"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wpna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-pulse-output-din-rail-mount-12240717840499.png?v=1572998385","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003ePulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eWM1-6 230WPNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eOpitonal 1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003eIP50 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 234px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 294px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$118.30exGST
Backorder
Quick View {"id":3952690626675,"title":"WM1-6 230WWNB, kWh Meter, 230VAC, Single Phase, 65 Amp Direct Connect, Bidirectional Counter, DIN Rail Mount","handle":"wm1-6-230wwnb","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eWM1-6 230WWNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eEnergy Meter Bidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e1200-19200 b\/s (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-08-29T14:37:50+10:00","created_at":"2019-08-29T14:37:50+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Measurement_240VAC","Special Feature_Bidirectional Counter","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ Single Phase"],"price":11830,"price_min":11830,"price_max":11830,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549709623411,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230WWNB","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230WWNB, kWh Meter, 230VAC, Single Phase, 65 Amp Direct Connect, Bidirectional Counter, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":11830,"weight":350,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wwnb-kwh-meter-230vac-single-phase-65-amp-direct-connect-bidirectional-counter-din-rail-mount-12222468653171.png?v=1572998516"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wwnb-kwh-meter-230vac-single-phase-65-amp-direct-connect-bidirectional-counter-din-rail-mount-12222468653171.png?v=1572998516","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eWM1-6 230WWNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eEnergy Meter Bidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e1200-19200 b\/s (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 219px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 309px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$169.20exGST
In stock
Quick View {"id":3952690561139,"title":"WM1-6 230WPNB, kWh Meter, 230VAC, 65 Amp Direct Connect, Single Phase, Bidirectional Counter, Pulse Output, DIN Rail Mount","handle":"wm1-6-230wpnb","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eWM1-6 230WPNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eEnergy Meter Bidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e19200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1200-19200 b\/s (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-08-29T14:37:49+10:00","created_at":"2019-08-29T14:37:50+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Measurement_240VAC","Special Feature_Bidirectional Counter","Special Feature_Pulse","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ Single Phase"],"price":16920,"price_min":16920,"price_max":16920,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549709590643,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230WPNB","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230WPNB, kWh Meter, 230VAC, 65 Amp Direct Connect, Single Phase, Bidirectional Counter, Pulse Output, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":16920,"weight":350,"compare_at_price":null,"inventory_management":"sos-inventory","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wpnb-kwh-meter-230vac-65-amp-direct-connect-single-phase-bidirectional-counter-pulse-output-din-rail-mount-12222468620403.png?v=1572998448"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wpnb-kwh-meter-230vac-65-amp-direct-connect-single-phase-bidirectional-counter-pulse-output-din-rail-mount-12222468620403.png?v=1572998448","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eWM1-6 230WPNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eEnergy Meter Bidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e19200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1200-19200 b\/s (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$251.00exGST
In stock
Quick View {"id":3952690495603,"title":"WM1-6 230CPNB, kWh Meter, 230VAC, Single Phase, 65 Amp Direct Connect, Bidirectional Counter, Pulse Output, RS485 Comms, DIN Rail Mount","handle":"wm1-6-230cpnb","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003ePulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eWM1-6 230CPNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-08-29T14:37:47+10:00","created_at":"2019-08-29T14:37:47+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Comms_RS485","Measurement_240VAC","Special Feature_Bidirectional Counter","Special Feature_Pulse","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ Single Phase"],"price":25100,"price_min":25100,"price_max":25100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549709525107,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230CPNB","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230CPNB, kWh Meter, 230VAC, Single Phase, 65 Amp Direct Connect, Bidirectional Counter, Pulse Output, RS485 Comms, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":25100,"weight":350,"compare_at_price":null,"inventory_management":"sos-inventory","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230cpnb-kwh-meter-230vac-single-phase-65-amp-direct-connect-bidirectional-counter-pulse-output-rs485-comms-din-rail-mount-12222468456563.png?v=1572998345"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230cpnb-kwh-meter-230vac-single-phase-65-amp-direct-connect-bidirectional-counter-pulse-output-rs485-comms-din-rail-mount-12222468456563.png?v=1572998345","options":["Title"],"content":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003ePulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eWM1-6 230CPNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\u003cspan\u003e19200 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 232px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 296px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$251.00exGST
In stock
Quick View {"id":3952690462835,"title":"WM1-6 230CPNA, kWh Meter, 230VAC, Single Phase, 65 Amp Direct Connect, Absolute Counter, Pulse Output, RS485 Comms, DIN Rail Mount","handle":"wm1-6-230cpna","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003ePulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eWM1-6 230CPNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e19200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-08-29T14:37:46+10:00","created_at":"2019-08-29T14:37:46+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Comms_RS485","Measurement_240VAC","Special Feature_Pulse","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ Single Phase"],"price":25100,"price_min":25100,"price_max":25100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549709492339,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230CPNA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230CPNA, kWh Meter, 230VAC, Single Phase, 65 Amp Direct Connect, Absolute Counter, Pulse Output, RS485 Comms, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":25100,"weight":350,"compare_at_price":null,"inventory_management":"sos-inventory","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230cpna-kwh-meter-230vac-single-phase-65-amp-direct-connect-absolute-counter-pulse-output-rs485-comms-din-rail-mount-12222468423795.png?v=1572998330"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230cpna-kwh-meter-230vac-single-phase-65-amp-direct-connect-absolute-counter-pulse-output-rs485-comms-din-rail-mount-12222468423795.png?v=1572998330","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003ePulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eWM1-6 230CPNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e19200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1200-19200 b\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$2,302.10exGST
Backorder
Quick View {"id":3952686170227,"title":"MC774 S H E W N N N, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Aux","handle":"mc774-s-h-e-w-n-n-n","description":"\u003cp\u003ePower Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Aux\u003c\/p\u003e","published_at":"2019-08-29T14:31:08+10:00","created_at":"2019-08-29T14:31:09+10:00","vendor":"Iskra Systemi","type":"Power Quality Analyser","tags":["Accuracy_Class A","Comms_Ethernet","Comms_USB","Measurement_1000VAC L-L","Measurement_600VAC","Style_Panel Mount","Supply Voltage_70-300VDC","Supply Voltage_80-276VAC","Type_ 3 Phase","Type_ Single Phase"],"price":230210,"price_min":230210,"price_max":230210,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549698613363,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MC774 S H E W N N N","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MC774 S H E W N N N, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Aux","public_title":null,"options":["Default Title"],"price":230210,"weight":750,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-power-quality-analyser-mc774-s-h-e-w-n-n-n-power-quality-analyser-class-a-32us-sampling-16-400hz-time-sychronisation-support-80-276vac-or-70-300vdc-aux-12222441488499.jpg?v=1572986569"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-power-quality-analyser-mc774-s-h-e-w-n-n-n-power-quality-analyser-class-a-32us-sampling-16-400hz-time-sychronisation-support-80-276vac-or-70-300vdc-aux-12222441488499.jpg?v=1572986569","options":["Title"],"content":"\u003cp\u003ePower Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Aux\u003c\/p\u003e"}
$546.00exGST
Backorder
Quick View {"id":3952686137459,"title":"MC330 H ARNG SINNNA, Panel Mount kWh Meter, Class 0.5s, 50-500VAC 50\/60Hz, Autoranging Measurement, 240VAC Aux","handle":"mc330-h-arng-sinnna","description":"\u003cp\u003ekWh Meter, Class 0.5s, 50-500VAC 50\/60Hz, Autoranging Measurement, 240VAC, Standard Mounting\u003c\/p\u003e","published_at":"2019-08-29T14:31:04+10:00","created_at":"2019-08-29T14:31:05+10:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 0.5s","Measurement_50-500VAC L-L","Style_Panel Mount","Supply Voltage_240VAC","Type_ 3 Phase","Type_ Single Phase","Type_3 Phase"],"price":54600,"price_min":54600,"price_max":54600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549698252915,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MC330-H-ARNG-SINNNA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MC330 H ARNG SINNNA, Panel Mount kWh Meter, Class 0.5s, 50-500VAC 50\/60Hz, Autoranging Measurement, 240VAC Aux","public_title":null,"options":["Default Title"],"price":54600,"weight":700,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc330-h-arng-sinnna-panel-mount-kwh-meter-class-0-5s-50-500vac-50-60hz-autoranging-measurement-240vac-aux-12222441455731.jpg?v=1572986333"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc330-h-arng-sinnna-panel-mount-kwh-meter-class-0-5s-50-500vac-50-60hz-autoranging-measurement-240vac-aux-12222441455731.jpg?v=1572986333","options":["Title"],"content":"\u003cp\u003ekWh Meter, Class 0.5s, 50-500VAC 50\/60Hz, Autoranging Measurement, 240VAC, Standard Mounting\u003c\/p\u003e"}
$831.20exGST
Backorder
Quick View {"id":3952686104691,"title":"M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC","handle":"m850-ldd","description":"\u003ch3\u003e\u003cspan style=\"color: #93bade;\"\u003e\u003cstrong\u003eHOBUT M850-LDD Dc KWh Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0-10 Amp direct connect, or 50,75mV Shunt\u003c\/li\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eLockable\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eUniversal Supply 100-440VAC, or 100-420VDC\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring DC electrical power networks. The meter records DC power according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of DC kWh Power\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eHOBUT Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eM850-LDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eDC Energy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003e100-440VAC, or 100-420VDC 0.5VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e15-150VDC or 30-300VDC, or 80-800VDC\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003e15-800VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1A-10A or 50mV\/75mV Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eClass 1 (I,U\u003cspan\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePanle Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e96 x 96 x 82mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e-20 →+60 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1569482936\/Hobut\/M850-MPDDCmeasuringmultifunctionmeters.pdf\" target=\"_blank\" title=\"HOBUT M850-MPD Series Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-08-29T14:31:03+10:00","created_at":"2019-08-29T14:31:04+10:00","vendor":"Hobut Howard Butler","type":"kWh Meter","tags":["Accuracy_Class 1","Measurement_80-800VDC","Style_Panel Mount","Supply Voltage_100-420VDC","Supply Voltage_100-440VAC","Type_ DC kWh Meter"],"price":83120,"price_min":83120,"price_max":83120,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29549698220147,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-M850-LDD","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC","public_title":null,"options":["Default Title"],"price":83120,"weight":500,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/hobut-howard-butler-kwh-meter-m850-ldd-dc-kwh-meter-96x96mm-800vdc-75mv-shunt-connected-rs485-lockable-100-240vac-or-100-420vdc-12222441324659.jpg?v=1572986271"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/hobut-howard-butler-kwh-meter-m850-ldd-dc-kwh-meter-96x96mm-800vdc-75mv-shunt-connected-rs485-lockable-100-240vac-or-100-420vdc-12222441324659.jpg?v=1572986271","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #93bade;\"\u003e\u003cstrong\u003eHOBUT M850-LDD Dc KWh Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0-10 Amp direct connect, or 50,75mV Shunt\u003c\/li\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eLockable\u003c\/li\u003e\n\u003cli\u003eOptional RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eUniversal Supply 100-440VAC, or 100-420VDC\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring DC electrical power networks. The meter records DC power according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of DC kWh Power\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eHOBUT Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eM850-LDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eDC Energy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003e100-440VAC, or 100-420VDC 0.5VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e15-150VDC or 30-300VDC, or 80-800VDC\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003e15-800VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1A-10A or 50mV\/75mV Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eClass 1 (I,U\u003cspan\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePanle Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e96 x 96 x 82mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eRS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 311px;\"\u003e-20 →+60 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1569482936\/Hobut\/M850-MPDDCmeasuringmultifunctionmeters.pdf\" target=\"_blank\" title=\"HOBUT M850-MPD Series Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$1,020.00exGST
Backorder
Quick View {"id":2014111989875,"title":"MC740 S S F E N N C, Panel Mount Multifunction Meter 3 Phase, Class 0.5, 415V 5Amp 50\/60Hz AC Measurement, 240VAC Supply, Ethernet \u0026 USB Comms, w\/ Supercap","handle":"mc740-s-s-f-e-n-n-c","description":"\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi MC740 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmart Meter\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 750 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5 or 0.2 (on demand)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of 40 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003e32 adjustable alarms\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS and DNP3 communication protocol\u003c\/li\u003e\n\u003cli\u003eMMC memory card for setting and upgrading the meter\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 750 V \u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003cli\u003e128 samples in one period\u003c\/li\u003e\n\u003cli\u003eMeasurement of THD on Current or Voltage from 0 to 400%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMC740 S S F E N N C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Quality Meter, Energy Meter, Power Transducer, Network Analyser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 Relays, 32 Alarms, 4 Groups) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 20mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBistable Relay Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eStatus (Watchdog) Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSupercap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eInternal Memory\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMMC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (MC750,MC760 optional up to 512MB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (\u003cspan\u003e2400-115200 b\/s)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (optional 2400-115200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807608\/Crouzet%20Automation\/Datasheets\/monitoring-relays-speed-monitoring-relays-din-rail-mount-35-mm-hsv-Part_number-84874320.pdf\" target=\"_blank\" title=\"Crouzet Automation 848744320 Speed Monitoring Relay\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1555394981\/Iskra%20Systemi\/Manuals\/K_MC7x0_GB_22440000_UsersManual_Ver_8.01.pdf\" target=\"_blank\" title=\"Iskra Systemi MC740 User Manual\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-03-31T14:08:45+11:00","created_at":"2019-03-31T14:08:46+11:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 0.5","Comms_Ethernet","Comms_USB","Measurement_240VAC","Measurement_415VAC L-L","Style_Panel Mount","Supply Voltage_24-300VDC","Supply Voltage_240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":102000,"price_min":102000,"price_max":102000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18422774071411,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MC740 S S F E N N C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MC740 S S F E N N C, Panel Mount Multifunction Meter 3 Phase, Class 0.5, 415V 5Amp 50\/60Hz AC Measurement, 240VAC Supply, Ethernet \u0026 USB Comms, w\/ Supercap","public_title":null,"options":["Default Title"],"price":102000,"weight":900,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc740-s-s-f-e-n-n-c-panel-mount-multifunction-meter-3-phase-class-0-5-415v-5amp-50-60hz-ac-measurement-240vac-supply-ethernet-usb-comms-w-supercap-647904310078.png?v=1572986394"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc740-s-s-f-e-n-n-c-panel-mount-multifunction-meter-3-phase-class-0-5-415v-5amp-50-60hz-ac-measurement-240vac-supply-ethernet-usb-comms-w-supercap-647904310078.png?v=1572986394","options":["Title"],"content":"\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi MC740 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmart Meter\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 750 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5 or 0.2 (on demand)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of 40 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003e32 adjustable alarms\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS and DNP3 communication protocol\u003c\/li\u003e\n\u003cli\u003eMMC memory card for setting and upgrading the meter\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 750 V \u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003cli\u003e128 samples in one period\u003c\/li\u003e\n\u003cli\u003eMeasurement of THD on Current or Voltage from 0 to 400%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMC740 S S F E N N C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Quality Meter, Energy Meter, Power Transducer, Network Analyser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 Relays, 32 Alarms, 4 Groups) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 20mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBistable Relay Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eStatus (Watchdog) Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSupercap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eInternal Memory\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMMC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (MC750,MC760 optional up to 512MB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (\u003cspan\u003e2400-115200 b\/s)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (optional 2400-115200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807608\/Crouzet%20Automation\/Datasheets\/monitoring-relays-speed-monitoring-relays-din-rail-mount-35-mm-hsv-Part_number-84874320.pdf\" target=\"_blank\" title=\"Crouzet Automation 848744320 Speed Monitoring Relay\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1555394981\/Iskra%20Systemi\/Manuals\/K_MC7x0_GB_22440000_UsersManual_Ver_8.01.pdf\" target=\"_blank\" title=\"Iskra Systemi MC740 User Manual\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$1,190.00exGST
Backorder
Quick View {"id":2014111924339,"title":"MC740 S S U E N N C, Panel Mount Multifunction Meter 3 Phase, Class 0.5, Universal Voltage 5Amp 50\/60Hz AC Measurement 240VAC Supply, Ethernet \u0026 USB Comms, w\/ Supercap","handle":"mc740-s-s-u-e-n-n-c","description":"\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi MC740 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmart Power Meter\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 750 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5 or 0.2 (on demand)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003e \u003c\/p\u003e\nMeasurement of 40 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003e32 adjustable alarms\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS and DNP3 communication protocol\u003c\/li\u003e\n\u003cli\u003eMMC memory card for setting and upgrading the meter\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 750 V \u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003cli\u003e128 samples in one period\u003c\/li\u003e\n\u003cli\u003eMeasurement of THD on Current or Voltage from 0 to 400%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMC740 S S U E N N C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Quality Meter, Energy Meter, Power Transducer, Network Analyser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal 48-240VAC 40-65Hz, 20-300VDC, \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 Relays, 32 Alarms, 4 Groups) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 20mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBistable Relay Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eStatus (Watchdog) Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSupercap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eInternal Memory\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMMC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eN\/A (optional up to \u003c\/span\u003e\u003cspan\u003e512\u003c\/span\u003e\u003cspan\u003eMB)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 10\/100Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYes (\u003c\/span\u003e\u003cspan\u003e2400-115200 b\/s)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (optional 2400-115200 b\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807608\/Crouzet%20Automation\/Datasheets\/monitoring-relays-speed-monitoring-relays-din-rail-mount-35-mm-hsv-Part_number-84874320.pdf\" target=\"_blank\" title=\"Crouzet Automation 848744320 Speed Monitoring Relay\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1555394981\/Iskra%20Systemi\/Manuals\/K_MC7x0_GB_22440000_UsersManual_Ver_8.01.pdf\" target=\"_blank\" title=\"Iskra Systemi MC740 User Manual\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-03-31T14:08:44+11:00","created_at":"2019-03-31T14:08:45+11:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Comms_Ethernet","Comms_USB","Measurement_240VAC","Measurement_415VAC L-L","Style_Panel Mount","Supply Voltage_240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":119000,"price_min":119000,"price_max":119000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18422774005875,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MC740 S S U E N N C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MC740 S S U E N N C, Panel Mount Multifunction Meter 3 Phase, Class 0.5, Universal Voltage 5Amp 50\/60Hz AC Measurement 240VAC Supply, Ethernet \u0026 USB Comms, w\/ Supercap","public_title":null,"options":["Default Title"],"price":119000,"weight":900,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc740-s-s-u-e-n-n-c-panel-mount-multifunction-meter-3-phase-class-0-5-universal-voltage-5amp-50-60hz-ac-measurement-240vac-supply-ethernet-usb-comms-w-supercap.png?v=1572986513"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc740-s-s-u-e-n-n-c-panel-mount-multifunction-meter-3-phase-class-0-5-universal-voltage-5amp-50-60hz-ac-measurement-240vac-supply-ethernet-usb-comms-w-supercap.png?v=1572986513","options":["Title"],"content":"\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi MC740 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmart Power Meter\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 750 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5 or 0.2 (on demand)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003e \u003c\/p\u003e\nMeasurement of 40 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003e32 adjustable alarms\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS and DNP3 communication protocol\u003c\/li\u003e\n\u003cli\u003eMMC memory card for setting and upgrading the meter\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 750 V \u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003cli\u003e128 samples in one period\u003c\/li\u003e\n\u003cli\u003eMeasurement of THD on Current or Voltage from 0 to 400%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMC740 S S U E N N C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Quality Meter, Energy Meter, Power Transducer, Network Analyser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal 48-240VAC 40-65Hz, 20-300VDC, \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 Relays, 32 Alarms, 4 Groups) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 20mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePulse Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBistable Relay Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eStatus (Watchdog) Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A (Optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Optional 4 x 230VAC\/DC,75..130VAC\/DC..5..48VAC\/DC) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSupercap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eInternal Memory\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMMC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eN\/A (optional up to \u003c\/span\u003e\u003cspan\u003e512\u003c\/span\u003e\u003cspan\u003eMB)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 10\/100Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYes (\u003c\/span\u003e\u003cspan\u003e2400-115200 b\/s)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (optional 2400-115200 b\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807608\/Crouzet%20Automation\/Datasheets\/monitoring-relays-speed-monitoring-relays-din-rail-mount-35-mm-hsv-Part_number-84874320.pdf\" target=\"_blank\" title=\"Crouzet Automation 848744320 Speed Monitoring Relay\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1555394981\/Iskra%20Systemi\/Manuals\/K_MC7x0_GB_22440000_UsersManual_Ver_8.01.pdf\" target=\"_blank\" title=\"Iskra Systemi MC740 User Manual\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$621.30exGST
2pcs in stock , more available 4-5 Weeks
Quick View {"id":2014688215155,"title":"MC330 H ARNG SUDMNAT, Panel Mount kWh Meter, Class 0.5, 50-500VAC Autorange, 60 Parameter (U, I, P, Q, S, PF, PA, f, ϴ, THD, MD …), 4 Energy Counters,16Hz to 400Hz, 2 x Relay Outputs, RS485 Comms, Universal 20-300VDC, 48-276VAC Aux Supply","handle":"mc330-h-arng-sudmnat","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e \u003cstrong\u003eIskra Systemi MC330 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal AC\/DC Power Supply\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 500 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eRMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive, apparent power and power factor\u003c\/li\u003e\n\u003cli\u003eMeasurements of energy in all 4 quadrants Average values of measurands per interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of 20 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003eOptional dual tariff inputs and pulse or relay outputs\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS communication protocol\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 600 V \u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 532px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eMC330 H ARNG SUDMNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePower Quality Meter, Energy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cspan\u003eUniversal 20-300VDC, 48-276VAC\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e600V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2 x Relay Outputs (Optional 2 more Relay\/Pulse Outputs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\u003cspan\u003eN\/A (Optional 4 x ) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD)  Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2400-115200 b\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1551062863\/Iskra%20Systemi\/Datasheets\/P_MC3x0x_New_Ver_8.00.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" title=\"MC330 Datasheet\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746653\/Iskra%20Systemi\/Manuals\/K_MC3x0x_GB_22444000_Users_manual_Ver_7.00.pdf\" target=\"_blank\" title=\"Iskra Systemi MC330 User Manual\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-04-01T18:28:49+11:00","created_at":"2019-04-01T18:28:50+11:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 0.5","Availability_In Stock","Measurement_50-500VAC L-L","Style_Panel Mount","Supply Voltage_20-300VDC","Supply Voltage_48-276VAC","Type_ 3 Phase","Type_ Single Phase","Type_3 Phase"],"price":62130,"price_min":62130,"price_max":62130,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18426344243315,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MC330 H ARNG SUDMNAT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MC330 H ARNG SUDMNAT, Panel Mount kWh Meter, Class 0.5, 50-500VAC Autorange, 60 Parameter (U, I, P, Q, S, PF, PA, f, ϴ, THD, MD …), 4 Energy Counters,16Hz to 400Hz, 2 x Relay Outputs, RS485 Comms, Universal 20-300VDC, 48-276VAC Aux Supply","public_title":null,"options":["Default Title"],"price":62130,"weight":700,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc330-h-arng-sudmnat-panel-mount-kwh-meter-class-0-5-50-500vac-autorange-60-parameter-u-i-p-q-s-pf-pa-f-thd-md-4-energy-counters-16hz-to-400hz-2-x-relay-output.jpg?v=1572986349"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc330-h-arng-sudmnat-panel-mount-kwh-meter-class-0-5-50-500vac-autorange-60-parameter-u-i-p-q-s-pf-pa-f-thd-md-4-energy-counters-16hz-to-400hz-2-x-relay-output.jpg?v=1572986349","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e \u003cstrong\u003eIskra Systemi MC330 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal AC\/DC Power Supply\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 500 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eRMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive, apparent power and power factor\u003c\/li\u003e\n\u003cli\u003eMeasurements of energy in all 4 quadrants Average values of measurands per interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of 20 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003eOptional dual tariff inputs and pulse or relay outputs\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS communication protocol\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 600 V \u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 532px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eMC330 H ARNG SUDMNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePower Quality Meter, Energy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cspan\u003eUniversal 20-300VDC, 48-276VAC\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e600V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2 x Relay Outputs (Optional 2 more Relay\/Pulse Outputs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\u003cspan\u003eN\/A (Optional 4 x ) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD)  Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2400-115200 b\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1551062863\/Iskra%20Systemi\/Datasheets\/P_MC3x0x_New_Ver_8.00.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" title=\"MC330 Datasheet\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746653\/Iskra%20Systemi\/Manuals\/K_MC3x0x_GB_22444000_Users_manual_Ver_7.00.pdf\" target=\"_blank\" title=\"Iskra Systemi MC330 User Manual\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$128.30exGST
5pcs in stock , more available 4-5 Weeks
Quick View {"id":1848676221043,"title":"WM1-6 230WWNA, DIN Rail Mount kWh Meter, 240VAC, 65 Amp, Single Phase, DIN Rail Mount","handle":"wm1-6-230wwna","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eOptional Modbus RS232\/RS485 communication up to 19,200 bit\/s communication\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 530px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eMC330 H ARNG SUDMNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e19200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e1200-19200 b\/s (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-12-18T18:40:17+11:00","created_at":"2018-12-18T18:40:18+11:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Availability_In Stock","Measurement_240VAC","Style_Din Rail Mount","Supply Voltage_240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":12830,"price_min":12830,"price_max":12830,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000291922035,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-WM1-6 230WWNA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"WM1-6 230WWNA, DIN Rail Mount kWh Meter, 240VAC, 65 Amp, Single Phase, DIN Rail Mount","public_title":null,"options":["Default Title"],"price":12830,"weight":350,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wwna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-din-rail-mount-5890957901939.png?v=1572998466"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-wm1-6-230wwna-din-rail-mount-kwh-meter-240vac-65-amp-single-phase-din-rail-mount-5890957901939.png?v=1572998466","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi WM1-6 Series Single Phase Power Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65 Amp direct connect, no CT's required\u003c\/li\u003e\n\u003cli\u003eUltra slim 2 DIN\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of Active and Reactive Power\u003c\/li\u003e\n\u003cli\u003eOptional Modbus RS232\/RS485 communication up to 19,200 bit\/s communication\u003c\/li\u003e\n\u003cli\u003eOptional Pulse Output\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with illumination\u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 530px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eMC330 H ARNG SUDMNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eEnergy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e \u0026lt; 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e230V L-N, 5 Amp +\/-20%\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003eV L-N, 5 Amp +\/-20%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eNominal Current Input\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e65 Amp AC Direct Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eInfra Red Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e19200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\u003cspan\u003eN\/A (Optional) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eClass 1 (I,U,F,PF,\u003cspan\u003e) Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eMounting \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e36 x 90 x 64mm (2 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003ePulse Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e1200-19200 b\/s (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 415.446px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113.554px;\"\u003e-20 →+70 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449104\/Iskra%20Systemi\/Datasheets\/P_WM1-6_GB_22433910_Ver_3.00.pdf\" target=\"_blank\" title=\"Iskra MT418 Series Measurement Transducer\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746655\/Iskra%20Systemi\/Manuals\/Users-manual-WM1.pdf\" target=\"_blank\" title=\"Iskra Systemi WM1-6-230 User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$485.00exGST
3pcs in stock , more available 4-5 Weeks
Quick View {"id":1848676122739,"title":"MC330 SEDMNAT 240\/E230 2RO\/RS48, Panel Mount kWh Meter, Class 0.5, 240VAC 60 Parameter (U, I, P, Q, S, PF, PA, f, ϴ, THD, MD...), 4 Energy Counters,16Hz to 400Hz, 2 x Relay Outputs, RS485 Comms, 230V\/240V Aux Supply","handle":"mc330sedmnat-240-e230-2ro-rs48","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi MC330 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 500 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eRMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive, apparent power and power factor\u003c\/li\u003e\n\u003cli\u003eMeasurements of energy in all 4 quadrants Average values of measurands per interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of 20 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003eOptional dual tariff inputs and pulse or relay outputs\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS communication protocol\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 600 V \u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 532px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eMC330 H ARNG SUDMNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePower Quality Meter, Energy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\u003cspan\u003e230V\/240VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e600V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2 x Relay Outputs (Optional 2 more Relay\/Pulse Outputs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\u003cspan\u003eN\/A (Optional 4 x ) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD)  Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2400-115200 b\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1546517124\/Iskra%20Systemi\/Datasheets\/P_MC3x0x_GB_22444000_Ver_8.01.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746653\/Iskra%20Systemi\/Manuals\/K_MC3x0x_GB_22444000_Users_manual_Ver_7.00.pdf\" target=\"_blank\" title=\"Iskra Systemi MC330 User Manual\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-12-18T18:40:16+11:00","created_at":"2018-12-18T18:40:16+11:00","vendor":"Iskra Systemi","type":"kWh Meter","tags":["Accuracy_Class 1","Availability_In Stock","Comms_RS232","Comms_RS485","Measurement_240VAC","Measurement_415VAC L-L","Special Feature_2 Relay Alarms","Style_Panel Mount","Supply Voltage_240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":48500,"price_min":48500,"price_max":48500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000290742387,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-MC330\/240V\/E230\/240-2RO\/WO-RS485","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MC330 SEDMNAT 240\/E230 2RO\/RS48, Panel Mount kWh Meter, Class 0.5, 240VAC 60 Parameter (U, I, P, Q, S, PF, PA, f, ϴ, THD, MD...), 4 Energy Counters,16Hz to 400Hz, 2 x Relay Outputs, RS485 Comms, 230V\/240V Aux Supply","public_title":null,"options":["Default Title"],"price":48500,"weight":700,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc330-sedmnat-240-e230-2ro-rs48-panel-mount-kwh-meter-class-0-5-240vac-60-parameter-u-i-p-q-s-pf-pa-f-thd-md-4-energy-counters-16hz-to-400hz-2-x-relay-outputs.jpg?v=1572986723"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/iskra-systemi-kwh-meter-mc330-sedmnat-240-e230-2ro-rs48-panel-mount-kwh-meter-class-0-5-240vac-60-parameter-u-i-p-q-s-pf-pa-f-thd-md-4-energy-counters-16hz-to-400hz-2-x-relay-outputs.jpg?v=1572986723","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi MC330 Series 3 Phase Multifunction Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic range of nominal current up to 12.5 A (Includes 5A\/1A CT Input) and nominal voltage up to 500 V L-N\u003c\/li\u003e\n\u003cli\u003eAdjustable tariff clock, display of electric energy consumption in optional currency\u003c\/li\u003e\n\u003cli\u003eOptional RS 232\/RS 485 communication up to 115,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eRMS values of currents and voltages\u003c\/li\u003e\n\u003cli\u003eMeasurements of active, reactive, apparent power and power factor\u003c\/li\u003e\n\u003cli\u003eMeasurements of energy in all 4 quadrants Average values of measurands per interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 0.5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement of 20 minimal and maximal values in different time periods\u003c\/li\u003e\n\u003cli\u003eOptional dual tariff inputs and pulse or relay outputs\u003c\/li\u003e\n\u003cli\u003eWide frequency range from 16 Hz to 400 Hz\u003c\/li\u003e\n\u003cli\u003eRS 232\/RS 485 communication up to 115,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003eMODBUS communication protocol\u003c\/li\u003e\n\u003cli\u003eUp to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)\u003c\/li\u003e\n\u003cli\u003eUniversal or AC power supply\u003c\/li\u003e\n\u003cli\u003eGraphic LCD 128 x 64 dots with illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic range of nominal current up to 5 A and nominal voltage up to 600 V \u003c\/li\u003e\n\u003cli\u003eMultilingual support\u003c\/li\u003e\n\u003cli\u003eUser-friendly PC MiQen software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 532px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eIskra Systemi Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eMC330 H ARNG SUDMNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePower Quality Meter, Energy Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\u003cspan\u003e230V\/240VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500V L-N, 5 Amp\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e600V L-N, 12.5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2 x Relay Outputs (Optional 2 more Relay\/Pulse Outputs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eTariff Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\u003cspan\u003eN\/A (Optional 4 x ) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass 0.5 (I,U,F,PF,\u003cspan\u003eθ,THD)  Class 1(Active), Class 2 (Reactive)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e2400-115200 b\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eUL, CSA, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eDegree on electrical equipment designed for use within certain voltage limits URLRS 53\/00 (Directive 73\/23\/EEC on low voltage): SIST EN 61010-1:2002\u003c\/p\u003e\n\u003cp\u003eSafety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement\u003c\/p\u003e\n\u003cp\u003eDecree on electromagnetic Compatibility (EMC) URLRS 61\/00 (Directive 89\/336\/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003cp\u003e600V rms, installation category II\u003c\/p\u003e\n\u003cp\u003e300V rms, installation category III\u003c\/p\u003e\n\u003cp\u003ePollution Degree 2 in compliance with SIST EN 61010-1:2002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eIP52 (IP00 for terminals) in compliance with SIST EN 60529:1997\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 414.58px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 115.42px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1546517124\/Iskra%20Systemi\/Datasheets\/P_MC3x0x_GB_22444000_Ver_8.01.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1560746653\/Iskra%20Systemi\/Manuals\/K_MC3x0x_GB_22444000_Users_manual_Ver_7.00.pdf\" target=\"_blank\" title=\"Iskra Systemi MC330 User Manual\" rel=\"noopener noreferrer\"\u003eUser Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$692.00exGST
Backorder
Quick View {"id":1848656953459,"title":"Multicube Modular TCP\/IP Comms Module","handle":"multicube-modular-tcp-ip-comms-module","description":"\u003cp\u003eMulticube Modular TCP\/IP Comms Module. To be accompanied by Multicube Modular Master Unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Multicube Modular TCP\/IP Comms Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires \u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master with Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaster Unit of Modular Multicube System\u003c\/li\u003e\n\u003cli\u003eOptional \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Multicube Master with Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eModbus RTU \u003cspan\u003e\u003ca href=\"https:\/\/fastron.com.au\/products\/multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e up to 19,200 bit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e20 Meters in same space as 4 traditional meters\u003c\/li\u003e\n\u003cli\u003e20 x 3 Phase or 60 x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eMODBUS RTU RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e2400-19200 b\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e175g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\"\u003eProduct brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery in 3-4 weeks if not in stock\u003c\/p\u003e","published_at":"2018-12-18T18:34:47+11:00","created_at":"2018-12-18T18:34:47+11:00","vendor":"Northern Design Electronics Ltd","type":"kWh Meter","tags":["Accuracy_Class 1","Comms_Ethernet","Style_Din Rail Mount","Style_Modular Meter","Supply Voltage 240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":69200,"price_min":69200,"price_max":69200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000256041075,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-Multicube Modular TCP\/IP Comms Module","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Multicube Modular TCP\/IP Comms Module","public_title":null,"options":["Default Title"],"price":69200,"weight":300,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-tcp-ip-comms-module-5890928607347.png?v=1572964279"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-tcp-ip-comms-module-5890928607347.png?v=1572964279","options":["Title"],"content":"\u003cp\u003eMulticube Modular TCP\/IP Comms Module. To be accompanied by Multicube Modular Master Unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Multicube Modular TCP\/IP Comms Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires \u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master with Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaster Unit of Modular Multicube System\u003c\/li\u003e\n\u003cli\u003eOptional \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Multicube Master with Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eModbus RTU \u003cspan\u003e\u003ca href=\"https:\/\/fastron.com.au\/products\/multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e up to 19,200 bit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e20 Meters in same space as 4 traditional meters\u003c\/li\u003e\n\u003cli\u003e20 x 3 Phase or 60 x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eMODBUS RTU RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e2400-19200 b\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e175g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\"\u003eProduct brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery in 3-4 weeks if not in stock\u003c\/p\u003e"}
$239.00exGST
Backorder
Quick View {"id":1848656887923,"title":"Multicube Modular RS485 Comms Module","handle":"multicube-modular-rs485-comms-module","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Multicube Modular RS485 Comms Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires \u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master with Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaster Unit of Modular Multicube System\u003c\/li\u003e\n\u003cli\u003eOptional \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Multicube Master with Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional pulse output modules\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eModbus \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e20 Meters in same space as 4 traditional meters\u003c\/li\u003e\n\u003cli\u003e20 x 3 Phase or 60 x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eMODBUS RTU RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2400-19200 b\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e175g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-12-18T18:34:46+11:00","created_at":"2018-12-18T18:34:46+11:00","vendor":"Northern Design Electronics Ltd","type":"kWh Meter","tags":["Accuracy_Class 1","Comms_RS485","Style_Din Rail Mount","Style_Modular Meter","Supply Voltage 240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":23900,"price_min":23900,"price_max":23900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000255975539,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-Multicube Modular RS485 Comms Module","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Multicube Modular RS485 Comms Module","public_title":null,"options":["Default Title"],"price":23900,"weight":300,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-rs485-comms-module-5890928574579.png?v=1572964263"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-rs485-comms-module-5890928574579.png?v=1572964263","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Multicube Modular RS485 Comms Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires \u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master with Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaster Unit of Modular Multicube System\u003c\/li\u003e\n\u003cli\u003eOptional \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Multicube Master with Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional pulse output modules\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eModbus \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e20 Meters in same space as 4 traditional meters\u003c\/li\u003e\n\u003cli\u003e20 x 3 Phase or 60 x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eMODBUS RTU RS485 communication up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2400-19200 b\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e175g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$1,056.00exGST
Backorder
Quick View {"id":1848656822387,"title":"Multicube Modular Master with Logger","handle":"multicube-modular-master-with-logger","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Multicube Modular Master Single and 3 Phase Power Meter with Logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaster Unit of Modular Multicube System\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003eAlternative\u003c\/span\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Master Product Page\" rel=\"noopener noreferrer\"\u003e master with logger\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e20 Meters in same space as 4 traditional meters\u003c\/li\u003e\n\u003cli\u003eExpandable to 20 x 3 Phase or 60 x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn Built Logger\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eOptional MODBUS RTU RS485 communication up to 19,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master with Logger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality, Network Recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eLogger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eN\/A (Optional 2400-19200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 100mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-12-18T18:34:45+11:00","created_at":"2018-12-18T18:34:46+11:00","vendor":"Northern Design Electronics Ltd","type":"kWh Meter","tags":["Accuracy_Class 1","Style_Din Rail Mount","Style_Modular Meter","Supply Voltage 240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":105600,"price_min":105600,"price_max":105600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000255942771,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-Multicube Modular Master with Logger","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Multicube Modular Master with Logger","public_title":null,"options":["Default Title"],"price":105600,"weight":700,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-master-with-logger-5890928410739.png?v=1572964188"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-master-with-logger-5890928410739.png?v=1572964188","options":["Title"],"content":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Multicube Modular Master Single and 3 Phase Power Meter with Logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaster Unit of Modular Multicube System\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003eAlternative\u003c\/span\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Master Product Page\" rel=\"noopener noreferrer\"\u003e master with logger\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e20 Meters in same space as 4 traditional meters\u003c\/li\u003e\n\u003cli\u003eExpandable to 20 x 3 Phase or 60 x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn Built Logger\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eOptional MODBUS RTU RS485 communication up to 19,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master with Logger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality, Network Recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eLogger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eN\/A (Optional 2400-19200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e500g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 100mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}
$239.00exGST
Backorder
Quick View {"id":1848656756851,"title":"Multicube Modular Digital Output Module","handle":"multicube-modular-digital-output-module","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eNorthern Design Multicube Modular Digital Output Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 12 Pulse or Alarm outputs. Requires \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Master Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emulticube modular master unit\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003eAlternative\u003c\/span\u003e \u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Master with Logger page\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOptional pulse output modules\u003c\/li\u003e\n\u003cli\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master\u003cspan\u003e \u003c\/span\u003ewith Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 3 phase Measurement Module\u003c\/li\u003e\n\u003cli\u003e2 x 3 Phase or 6x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eOptional MODBUS RTU RS485 communication up to 19,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eN\/A (Optional 2400-19200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\"\u003eProduct brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery generally in 3-4 weeks if not in stock\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\"\u003eProduct brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery generally in 3-4 weeks if not in stock\u003c\/p\u003e","published_at":"2018-12-18T18:34:44+11:00","created_at":"2018-12-18T18:34:45+11:00","vendor":"Northern Design Electronics Ltd","type":"kWh Meter","tags":["Accuracy_Class 1","Style_Din Rail Mount","Style_Modular Meter","Supply Voltage 240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":23900,"price_min":23900,"price_max":23900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000255844467,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-Multicube Modular Digital Output Module","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Multicube Modular Digital Output Module","public_title":null,"options":["Default Title"],"price":23900,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-digital-output-module-5890928148595.png?v=1572964074"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-digital-output-module-5890928148595.png?v=1572964074","options":["Title"],"content":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eNorthern Design Multicube Modular Digital Output Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 12 Pulse or Alarm outputs. Requires \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Master Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emulticube modular master unit\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 Phase Circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003eAlternative\u003c\/span\u003e \u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Master with Logger page\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOptional pulse output modules\u003c\/li\u003e\n\u003cli\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master\u003cspan\u003e \u003c\/span\u003ewith Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 3 phase Measurement Module\u003c\/li\u003e\n\u003cli\u003e2 x 3 Phase or 6x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eOptional MODBUS RTU RS485 communication up to 19,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12 (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eN\/A (Optional 2400-19200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\"\u003eProduct brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery generally in 3-4 weeks if not in stock\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\"\u003eProduct brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery generally in 3-4 weeks if not in stock\u003c\/p\u003e"}
$239.00exGST
Backorder
Quick View {"id":1848656691315,"title":"Multicube Modular Measurement Module","handle":"multicube-modular-measurement-module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eNorthern Design Multicube Modular Single and 3 Phase Measurement Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules. Requires \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Master Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emulticube modular master unit\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 phase or 1 x single phase circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003eAlternative\u003c\/span\u003e \u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Master with Logger page\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOptional pulse output modules\u003c\/li\u003e\n\u003cli\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master\u003cspan\u003e \u003c\/span\u003ewith Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 3 phase Measurement Module\u003c\/li\u003e\n\u003cli\u003e2 x 3 Phase or 6x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eOptional MODBUS RTU RS485 communication up to 19,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eN\/A (Optional 2400-19200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan style=\"color: #0000ff;\"\u003eDatasheet\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-12-18T18:34:43+11:00","created_at":"2018-12-18T18:34:44+11:00","vendor":"Northern Design Electronics Ltd","type":"kWh Meter","tags":["Accuracy_Class 1","Measurement_240VAC","Measurement_415VAC L-L","Style_Din Rail Mount","Style_Modular Meter","Supply Voltage 240VAC","Type_ 3 Phase","Type_ Single Phase"],"price":23900,"price_min":23900,"price_max":23900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18000255778931,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FE-Multicube Modular Measurement Module","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Multicube Modular Measurement Module","public_title":null,"options":["Default Title"],"price":23900,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":null}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-measurement-module-5890928017523.png?v=1572964162"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/northern-design-electronics-ltd-kwh-meter-multicube-modular-measurement-module-5890928017523.png?v=1572964162","options":["Title"],"content":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eNorthern Design Multicube Modular Single and 3 Phase Measurement Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 20 Meters in 1 with additional modules. Requires \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Master Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emulticube modular master unit\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum 2 x 3 phase or 1 x single phase circuits with \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-measurement-module\" target=\"_blank\" title=\"Multicube Modular Measurement Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003emeasurement module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003eAlternative\u003c\/span\u003e \u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Master with Logger page\" rel=\"noopener noreferrer\"\u003emaster with logger\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOptional pulse output modules\u003c\/li\u003e\n\u003cli\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"multicube-modular-master\" target=\"_blank\" title=\"Multicube Modular Master Product Page\" rel=\"noopener noreferrer\"\u003eM\u003cspan style=\"color: #0000ff;\"\u003eulticube Modular Master \u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-master-with-logger\" target=\"_blank\" title=\"Logger Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eMulticube Master\u003cspan\u003e \u003c\/span\u003ewith Logger\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional 12 way pulse\/alarm \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-digital-output-module\" target=\"_blank\" title=\"Multicube Digital I\/O Modules Product Page\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003edigital output modules\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L\u003c\/li\u003e\n\u003cli\u003eGraphic Display\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"multicube-modular-rs485-comms-module\" target=\"_blank\" title=\"RS485 Comms Module Product Page\" rel=\"noopener noreferrer\"\u003eRS485\u003c\/a\u003e or \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"multicube-modular-tcp-ip-comms-module\" target=\"_blank\" title=\"Ethernet Communication Module\" style=\"color: #0000ff;\" rel=\"noopener noreferrer\"\u003eEthernet communication\u003c\/a\u003e\u003c\/span\u003e up to 19,200 bit\/s\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement of currents and voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 3 phase Measurement Module\u003c\/li\u003e\n\u003cli\u003e2 x 3 Phase or 6x Single Phase Circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"display: inline !important;\"\u003eAccuracy class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimple Menu\u003c\/li\u003e\n\u003cli\u003eOptional MODBUS RTU RS485 communication up to 19,200 bit\/s or Ethernet communication\u003c\/li\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003e240V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 525px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eNorthern Design Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eMulticube Modular Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003ekWh Meter, Energy Meter, Power Quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cspan\u003e240VAC\u003c\/span\u003e \u0026lt; 15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eNominal Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e415V L-L 240V L-N, 0.333V\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eMaximum Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e480V L-L 280V L-N, 0.383V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eClass 1 (kW,kWh\u003cspan\u003e)  Class 1(Active), Class 2 Reactive\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEthernet\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e2.11kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eRS232\/RS485\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eN\/A (Optional 2400-19200 b\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eEN 61010-1 Installation Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e IP54\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u003cspan\u003eABS with fire protection to UL94-V-O. Self extinguishing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cb\u003eEnclosureSize\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e164 x 96mm x 29mm \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003eRising Cage 4mm\u003cspan\u003e²\u003c\/span\u003e (12 AWG) cable max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e\u0026lt; 75% Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 253.866px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 272.134px;\"\u003e-20 →+70 °C  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan style=\"color: #0000ff;\"\u003eDatasheet\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1549941387\/Northern%20Design\/MultiCube_Modular_Meter_Brochure_2012.07.pdf\" target=\"_blank\" title=\"Modular Multicube Brochure\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533449721\/Northern%20Design\/Modular%20Multicube\/ND_MultiCube_modular_meter_Modbus_Comms_Manual_March_2011.pdf\" target=\"_blank\" title=\"Modular Multicube User Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eUser manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e"}