ST5593D, Surge Protection Device (SPD), 400VAC, Panel Mount with PE Wire, for Direct Lightning strikes
Specifications
Fastron part number
ST5593D
Category IEC / EN / VDE
Class II / Type 2 / A
Location of use
Substation
Protection modes
L/N-PE
Protective element
Back to Back Diodes
Surge discharge rating
Imax up to 200 kA
Internal protection and safety
N/A Diode fails to short or open ciruit
Standards
IEC/EN 61643-11
Iskra ISPRO-K BSR 100/440 (3+1), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 100kA, 440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Iskra Doo part number
ISPRO-K BSR 100/440 (3+1)
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Overhead power lines
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 75 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Iskra ISPRO-K BSR 75/440 (3+0), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount
Specifications
Iskra Doo part number
ISPRO-K BSR 75/440 (3+0)
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Protective element
MOV + GDT
Surge discharge rating
Imax up to 75 kA, or 25kA per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
HVBD6AAR, Hermetic Battery Switch with Red Handle, SPST 1 x 600 Amp 1500VDC, with Auxiliary Contact, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1500VDC Battery/Solar Isolation
Standards :
OSHA (LOTO)
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD6AAR
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1500VDC (5375VDC 1 min)
Nominal Current
1 x 600 Amp DC
Auxilairy Contact
3 Amp @ 12VDC 100k Cycles
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1500VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Datasheet
Product Datasheet
Rincon Power Product Portfolio
HVBD6AXR, Hermetic Battery Switch with Red Handle, SPST 1 x 600 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1000VDC Battery/Solar Isolation
Standards :
OSHA (LOTO)
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD6AXR
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1500VDC (5375VDC 1 min)
Nominal Current
1 x 600 Amp DC
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1000VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Datasheet
Product Datasheet
Rincon Power Product Portfolio
HHVBD4AAR, Hermetic Battery Switch with Red Handle, SPST 1 x 400 Amp 1500VDC, with Auxiliary Contact, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1500VDC Battery/Solar Isolation
Standards :
OSHA (LOTO)
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD4AAR
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1500VDC (5375VDC 1 min)
Nominal Current
1 x 600 Amp DC
Auxilairy Contact
3 Amp @ 12VDC 100k Cycles
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1500VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Datasheet
Product Datasheet
Rincon Power Product Portfolio
HBD41AB, Hermetic Battery Switch with Black Handle, SPST 1 x 400 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1000VDC Battery/Solar Isolation
Standards :
OSHA
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Iskra Systemi Part Number
HBD41AB
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Black Handle
Nominal Voltage
1000VDC
Nominal Current
1 x 400 Amp DC
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1000VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Standards
OSHA, CE
Weight
700g
Enclosure Material
Zytel
Factory Pack Qty
10
Datasheet
Product Datasheet
HBD41AA, Hermetic Battery Switch with Red Handle, SPST 1 x 400 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1000VDC Battery/Solar Isolation
Standards :
OSHA
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Iskra Systemi Part Number
HBD41AA
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1000VDC
Nominal Current
1 x 400 Amp DC
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1000VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Standards
OSHA, CE
Weight
700g
Enclosure Material
Zytel
Factory Pack Qty
10
Datasheet
Product Datasheet
HVBD3AAR, Hermetic Battery Switch with Red Handle, SPST 1 x 300 Amp 1500VDC, with Auxiliary Contact, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1500VDC Battery/Solar Isolation
Standards :
OSHA (LOTO)
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD3AAR
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1500VDC (5375VDC 1 min)
Nominal Current
1 x 300 Amp DC
Auxilairy Contact
3 Amp @ 12VDC 100k Cycles
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1500VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Datasheet
Product Datasheet
Rincon Power Product Portfolio
HVBD4AXR Rev J, Hermetic Battery Switch with Red Handle, SPST 1 x 400 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1000VDC Battery/Solar Isolation
Standards :
OSHA
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD4AXR Rev J (1000VDC only)
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1000VDC (5000VDC 1 min)
Nominal Current
1 x 400 Amp DC
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1000VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Datasheet
Product Datasheet
Rincon Power Product Portfolio
Trent FBT P BCM12.5 275 RM (3+0) (Modules), MODULES ONLY for Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD), 12.5KA/60kA per Pole
Specifications
Trent part number
FBT P BCM12.5 275 RM (3+0 Modules)
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV
Surge discharge rating
Imax up to 37.5 kA(10/350us) / 100kA(8/20us) or 12.5kA(10/350us) / 60kA(8/20us) per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Manual Battery Switch, DPST 2 x 500 Amp 32VDC, Flange Mount 120mm Wide, M10 Terminations, IP67/IEC529
DC battery switches are designed to be placed in between the battery and load. Suitable for any low voltage DC application which requires up to 2kA overload for 1.5 minutes.
Features :
2 Pole Disconnect
Suitable for DC Isolation
Standards :
IEC 60364-7-712
IP65 (Front) IP20 (Terminals)
Specification
Gigavac Part Number
BD9513
Functions
2 Pole DC DPST Disconnect Switch, ON/OFF Red Lever
Nominal Voltage
32VDC
Nominal Current
2 x 500 Amp DC
Rated Impulse Voltage
1.05kV (1 min)
Rated Insulation Voltage
32VDC
Short Circuit Current
2kA (1.5 min), 2.5kA (10s)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
N/A
Standards
IP67/IEC529
Termination
M10
Weight
700g
Enclosure Material
Zytel
Factory Pack Qty
10
Datasheet
Product Datasheet
Protec Protec T1-750-3+0-R, 750VAC Surge Protection Device for 600VAC Systems, Type 1, Type 2/Open Type 1CA, SPD Listed, with Remote Contact
Specifications
Raycap part number
Protec Protec T2 Protec T2-750-3+0-R
Nominal Voltage
750VAC (for 600VAC systems)
No of Poles
3
Category IEC / EN / VDE
Type 1, Type 2/Open Type 1CA SPD Listed
Location of use
Sub Distribution Boards
Protection modes
L-PEN
Additional Remote Contacts
YES
Protective element
MOV + GDT
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 20kA (10/350uS), 60kA(8/20uS)
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Trent FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type
Specifications
Trent part number
FBT P BCM12.5 275 RM (4+0)
Nominal Voltage
440VAC
No of Poles
4
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV
Additional Remote Contacts
YES
Protective element
MOV
Surge discharge rating
Imax up to 37.5 kA(10/350us) / 100kA(8/20us) or 12.5kA(10/350us) / 60kA(8/20us) per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Iskra Doo MS32-4, Motor Protection Switch, 3 Phase, 690VAC, 2.5 - 4 Amp Setting Range, Thermal & Magnetic Release
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal & Magnetic release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-4
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
2.5 - 4 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series
Trent FRS7-B+C 37.5/440 (3+0)R, Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Trent part number
FRS7-B+C 37.5/440 (3+0)R
Nominal Voltage (Un) L-L
400VAC
Maximum Voltage (Uc) L-L
440VAC
No of Poles
3
Voltage Protection Level (Up)
< 2.2kV
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 50 kA, or 12.5kA per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Trent FBT P BCM12.5 275 RM (3+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type
Specifications
Trent part number
FBT P BCM12.5 275 RM
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV
Additional Remote Contacts
YES
Protective element
MOV
Surge discharge rating
Imax up to 37.5 kA(10/350us) / 100kA(8/20us) or 12.5kA(10/350us) / 60kA(8/20us) per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Protec Protec T1-750-3+0-R, 750VAC Surge Protection Device for 600VAC Systems, Type 1, Type 2/Open Type 1CA, SPD Listed, with Remote Contact
Specifications
Raycap part number
Protec Protec T2 Protec T2-750-3+0-R
Nominal Voltage
750VAC (for 600VAC systems)
No of Poles
3
Category IEC / EN / VDE
Type 1, Type 2/Open Type 1CA SPD Listed
Location of use
Sub Distribution Boards
Protection modes
L-PEN
Additional Remote Contacts
YES
Protective element
MOV + GDT
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 20kA (10/350uS), 60kA(8/20uS)
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Protec Protec T2 Protec T2-350-3+0-R, Uc = 350VAC Surge Protection Device (SPD) for AC Applications, 20kA (10/350uS), Varistor Voltage. For 277VAC systems, 3 Pole + 0, DIN Rail Mount, Protection Modes L-PEN, Class II, Type 2, Type 1CA, Open Type 1 SPD Listed, with Remote Contact
Specifications
Raycap part number
T2 Protec T2-350-3+0-R
Nominal Voltage Un
277VAC systems (for Uc = 350VAC )
No of Poles
3
Category IEC / EN / VDE
Type 2/Open Type 1CA SPD Listed
Location of use
Sub Distribution Boards
Protection modes
L-PEN
Additional Remote Contacts
YES
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 20kA(8/20uS) 50kA Max
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Iskra ISPRO BSR 25/440, Class I, II / Type 1,2 / B, C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Iskra Doo part number
ISPRO BSR 25/440
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 25 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
ISPRO C 120/275 (3+0),Class II / Type 2 / C, Modular Surge Protection Device (SPD) 3 Pole 40kA,275VAC, DIN Rail Mount. For Sub Distribution Boards
Specifications
Iskra Doo part number
ISPRO C 120/275 (3+0)
Nominal Voltage
275VAC
No of Poles
3 (via 3 modules)
Category IEC / EN / VDE
Class II / Type 2 / C
Location of use
Sub Distribution Boards
Additional Remote Contacts
NO
Protection modes
L/N-PE
Protective element
MOV + GDT
Surge discharge rating
Imax up to 40 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Trent FRS4-B50/150/R 3P+N, 4 Pole, Un = 120VAC, Uc = 150VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 50kA, Pluggable, With Remote Contacts
Specifications
Trent part number
FRS4-B50/150/R 3P+N
Nominal Voltage (Un)
120VAC
Maximum Operating Voltage (Uc)
150VAC
Voltage Protection Level (Up)
<1.25kV
No of Poles
4
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution Boards
Protection modes
L-L, L-PE, High Energy MOV
Additional Remote Contacts
YES (1 x CO)
Protective element
MOV
Surge discharge rating
Imax up to 40kA(8/20us) L-PE/L-L 350VAC / 20kA(8/20us) L-PE/L-L
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Trent FRS4-C40/350VAC (R), 4 Pole, Un = 240VAC, Uc = 350VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With Remote Contacts
Specifications
Trent part number
FRS4-C40/350VAC (R)
Nominal Voltage (Un)
240VAC
Maximum Operating Voltage (Uc)
350VAC
Voltage Protection Level (Up)
<1.75kV
No of Poles
4
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution Boards
Protection modes
L-L L-PE, High Energy MOV
Additional Remote Contacts
YES (1 x CO)
Protective element
MOV
Surge discharge rating
Imax up to 40kA(8/20us) L-PE/L-L 350VAC / 20kA(8/20us) L-PE/L-L
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Trent FRS4-C40/480V/R/3P+1 (R),4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts
Specifications
Trent part number
FRS4-C40/480V/R/3P+1 (R)
Nominal Voltage (Un)
480VAC
Maximum Operating Voltage (Uc)
L-L : 960 V AC ; L-PE : 880VAC
Voltage Protection Level (Up)
L-L: ≤ 3.8kV; L-PE: ≤ 5.1kV
No of Poles
3 + 1
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution Boards
Protection modes
L-L L-PE, High Energy MOV
Additional Remote Contacts
YES (4x)
Protective element
MOV
Surge discharge rating
Imax up to 40kA(8/20us) L-PE/L-L 320VAC / 20kA(8/20us) L-PE/L-L
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet