Split Core Current Transformers with 10-19mm Aperture
-
SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-5A, 5 Amp Output, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100-5A Technology Split Core AC Current Transformer Ratio 100/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
SCT-F16-100, 100/0.333V Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100, 0.333V Output, 100Amp measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100 Technology Split Core AC Current Transformer Ratio 100/0.333V Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
SCT-F16-120-40mA(SCT-F16-120-040A), 40mA, 120Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-120-40mA(SCT-F16-120-040A), 40mA, 120Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 40 mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-120-040A Technology Split Core AC Current Transformer Ratio 120/40mA Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 40 mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 120Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
SCT-F16-120-5A, 120/5Amp Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendFastron Electronics SCT-F16-120-5A, 5 Amp Output, 120Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-120-5A Technology Split Core AC Current Transformer Ratio 120/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 120Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
Free Aus Post Shipping for $300 Spend$45.00
$53.10 inclGST -
SCT-F10-20, 20Amp/0.333V Measurement, Class 1 Split Core CT's Class 1
Fastron Electronics SCT-F10-20, 20 Amp, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F10-20 Technology Split Core AC Current Transformer Ratio 20/0.333v Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 20Amp x 1.2 Termination Style 0.9M Flying Leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$39.00
$46.02 inclGST -
SCT-F16-20-1A, 20/1Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-20-1A, 20/1Amp Measurement, Class 1 Split Core Current Transformer Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-20-1A Technology Split Core AC Current Transformer Ratio 20/1A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 20Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
SCT-F16-150-5A, 150/5 Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-150-5A, 150/5 Amp Measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-150-5A Technology Split Core AC Current Transformer Ratio 150/5 Amp Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
SCT-F16-100-40mA, 40mA, 100Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-40mA, 40mA, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 40 mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100-40mA Technology Split Core AC Current Transformer Ratio 100/40mA Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 0.5 Output 40 mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
SCT-F16-100-33.3mA, 100/33.3mA Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-33.3mA, 100/33.3mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100-33.3mA Technology Split Core AC Current Transformer Ratio 100/33.3mAV Aperture Size ø 16 mm VA Rating N/A Accuracy Class Class 1 Output 33.33mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
SCT-F10-5, 5 Amp, 0.333v Class 1 Series Current Transformer
Fastron Electronics SCT-F10-5, 5 Amp, 0.333v Class 1 Series Current Transformer, Equivalent to SCT-0400-10 (CE Approval, No UL approval) Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F10-5 Technology Split Core AC Current Transformer Ratio 5/0.333v Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 5Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide UL Approved Version SCT-0400-05
$39.00
$46.02 inclGST -
SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1
Fastron Electronics SCT-10-75, 75 Amp, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F10-75 Technology Split Core AC Current Transformer Ratio 75/0.333v Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 75Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$39.00
$46.02 inclGST -
SCT-F16-20-5A-CL5, 5 Amp, 20Amp Measurement, Class 5 Split Core CT's
Fastron Electronics SCT-F16-20-5A-CL5, 5 Amp, 20Amp measurement Split Core CT's CLASS 5 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-20-5A-CL5 Technology Split Core AC Current Transformer Ratio 20/5 Amp Aperture Size ø 16 mm VA Rating N/A Accuracy Class Class 2 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 20Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST