Hall Effect Voltage Sensors

115 products

  • Magnelab Inc DC Voltage Transducer DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response FE-DVT-1000-420

    DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response

    8 pcs in stock

    Magnelab DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response 10mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Magnelab Part Number DVT-1000-420 Control Output 4-20mA Input 10 - 1000VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 15 - 48VDC Voltage Isolation (1 min) 4.5kV Accuracy 1% Response Time 10mS Termination Style Screw Mounting Style DIN Rail Mount Safety UL508C, CSA C22.2 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet

    8 pcs in stock

    $575.00
    $678.50 inclGST

  • DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip

    DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip

    49 pcs in stock

    LEM DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 35kHz 8 Pins +/-15..24VDC Unipolar Supply 4-20mA Unipolar Output Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24VDC Primary Nominal Voltage +/-1000V Measurement Range +/-1500V Output 4-20mA Unipolar Instantaneous (0.5mA underange/21mA overrange) Isolation 4.2 kV Bandwidth DC-35 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    49 pcs in stock

    $304.80
    $359.66 inclGST

  • FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response

    FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response

    11 pcs in stock

    Fastron FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-50-420-24 Analogue Output 4-20mA Input 0 - 50VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet  

    11 pcs in stock

    $265.00
    $312.70 inclGST

  • DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    36 pcs in stock

    LEM DVL 2000 Series Closed Loop AC/DC Digital Voltage Transducer 2000V Input, 50mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    36 pcs in stock

    $565.00
    $666.70 inclGST

  • 93.30.R2.000.0, Din Rail Clip for DVC 1000, DVC 1000-B, DVC 1000-UI, DVC 50

    93.30.R2.000.0, Din Rail Clip for DVC 1000, DVC 1000-B, DVC 1000-UI, DVC 50

    105 pcs in stock

    LEM 93.30.R2.000.0, Din Rail Clip for DVC 1000, DVC 1000-B, DVC 1000-UI, DVC 50      

    105 pcs in stock

    $7.00
    $8.26 inclGST

  • DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip

    DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip

    129 pcs in stock

    LEM DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 47kHz Wago 2061 Connections +/-15...24VDC Bipolar Supply Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15...24VDC Primary Nominal Voltage +/-1000V AC/DC Measurement Range +/-1500V AC/DC Output +/-6.66 VDC Instantaneous (+/-10VDC over range) Isolation 4.2 kV Bandwidth DC-37 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style WAGO 2016 Connectors Unit Weight 57g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition      

    129 pcs in stock

    $284.50
    $335.71 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVC 1000-P, C/L Voltage Transducer, 1000V, 5VDC Supply FE-DVC 1000-P

    DVC 1000-P, C/L Voltage Transducer, 1000V AC/DC, 5VDC Supply, 2.5Vref Instantaneous Output, PCB Mount

    48 pcs in stock

    LEM DVC 1000-P, C/L Voltage Transducer, 1000V AC/DC, 5VDC Supply, 2.5Vref Output, PCB Mount Features Bandwidth DC to 47kHz 8 Pins 5V Unipolar Supply Closed loop transducer using Hall Effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-P Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage 5VDC Primary Nominal Voltage +/-1000V AC/DC Measurement Range +/-1500V AC/DC Output 2.5V Vref 1.17V -> 3.83V (0.5 to 4.5V over range) Instantaneous Isolation 4.2 kV Bandwidth DC-47 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    48 pcs in stock

    $183.83
    $216.92 inclGST

  • Last stock! DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    4 pcs in stock

    LEM DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 500V Measurement Range +/- 750V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    4 pcs in stock

    $551.00
    $650.18 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 500 UI, Digital Voltage Transducer 500V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    9 pcs in stock

    LEM DVL 500 UI, Digital Voltage Transducer 500V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 500 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 500V Measurement Range +/- 750V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    9 pcs in stock

    $661.00
    $779.98 inclGST

  • DVC 1000, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15..24VDC Supply, Isn= +/-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip

    DVC 1000, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15..24VDC Supply, Isn= +/-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip

    64 pcs in stock

    LEM DVC 1000, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15..24VDC Supply, Isn= +/-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 35kHz Wago 2061 Connections +/-15..24VDC Unipolar Supply Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24VDC Primary Nominal Voltage +/-1000V AC/DC Measurement Range +/-1500V AC/DC Output +/-20mAInstantaneous (+/-30mA Over range) Isolation 4.2 kV Bandwidth DC-35 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style WAGO 2016 Connectors Unit Weight 57g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    64 pcs in stock

    $240.40
    $283.67 inclGST

  • FDV-100-420-24, DC Voltage Transducer, Din Rail Mount, 0-100VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response FDV-100-420-24, DC Voltage Transducer, Din Rail Mount, 0-100VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response

    FDV-100-420-24, DC Voltage Transducer, Din Rail Mount, 0-100VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response

    10 pcs in stock

    Fastron FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-100VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-50-420-24 Analogue Output 4-20mA Input 0 - 50VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet  

    10 pcs in stock

    $265.00
    $312.70 inclGST

  • FDV-1000-420-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response FDV-1000-420-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response

    FDV-1000-420-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response

    20 pcs in stock

    Fastron FDV-1000-420-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-1000-420-24 Analogue Output 4-20mA Input 0 - 1000VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet

    20 pcs in stock

    $265.00
    $312.70 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account