LEM Hall Effect Current Sensors PCB Mount

206 products

  • HXN 30-P Hall Effect Current Sensor, 30 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 30-P Hall Effect Current Sensor, 30 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 30-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 30-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 30 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 25-P/SP40 Hall Effect Current Sensor, 25 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 25-P/SP40 Hall Effect Current Sensor, 25 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 25-P/SP40 Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 25-P/SP40 Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 25-P Hall Effect Current Sensor, 25 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 25-P Hall Effect Current Sensor, 25 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 25-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 25-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 20-P Hall Effect Current Sensor, 20 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 20-P Hall Effect Current Sensor, 20 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 20-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 20-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 20 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 15-P Hall Effect Current Sensor, 15 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 15-P Hall Effect Current Sensor, 15 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 15-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 15-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 15 Amp Measurement Range +/-45 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 10-P Hall Effect Current Sensor, 10 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 10-P Hall Effect Current Sensor, 10 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 10-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 10-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 5 Amp Measurement Range +/-15 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 05-P Hall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 05-P Hall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 05-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 05-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 5 Amp Measurement Range +/-15 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HXN 03-P Hall Effect Current Sensor, 3 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HXN 03-P Hall Effect Current Sensor, 3 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 03-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 03-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 3 Amp Measurement Range +/-6 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HX 60-P Hall Effect Current Sensor, 60 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HX 60-P Hall Effect Current Sensor, 60 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HX 60-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HX 60-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 60 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HX 15-NP Hall Effect Current Sensor, 15 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HX 15-NP Hall Effect Current Sensor, 15 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 15-NP Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HX 15-NP Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 15 Amp Measurement Range +/-45 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HX 10-NP Hall Effect Current Sensor, 10 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HX 10-NP Hall Effect Current Sensor, 10 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 10-NP Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HX 10-NP Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 10 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

  • HX 05-NP Hall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    HX 05-NP Hall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%

    Out of stock

    LEM HXN 05-NP Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HX 05-NP Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 5 Amp Measurement Range +/-15 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.80
    $32.80 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account