Recommended products
-
SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's
Fastron Electronics SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-200-5A Technology Split Core AC Current Transformer Ratio 200/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
F2D200-500, Solid State Relay, DC 4-32VDC control, 200A, 12-500VDC Load
Fastron F2D200-500, Solid State Relay, DC 4-32VDC control, 200A, 12-500VDC Load Features Ratings from 7A to 100 Amp @ 1-480VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Fastron Part Number F2D200-500 Switching Type DC Load Control Voltage 4-32VDC Load Current 200 Amp DC Surge Capability (10ms) 300 Amp DC Special Feature LED Indicator Mounting Style Panel Mount Load Voltage Range 12 - 500VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$99.00
$116.82 inclGST -
SCT-F24-200-40mA, 40mA, 200Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-200-40mA, 50mA, 200Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F24-200-40mA Technology Split Core AC Current Transformer Ratio 200/40mA Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 40mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$50.50
$59.59 inclGST -
DHAB S/137, Automotive Hall Effect Sensor, Dual Measurement Range, CH1: +/-75A CH2: +/-1000A, Cable or Panel Mount, 22.5mm round aperture
LEM DHAB S/137 Series O/L Automotive AC/DC Current Transducer, Multirange Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-75A, and +/-1000A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number DHAB S/137 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-75 Amp Load Current Channel 2 (RMS) +/-1000 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 70Hz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 15%(0A),0.7%(25A),1.3%(75A) CH2 Accuracy @ 25 Deg C 3%(0A),9%(500A),15%(900A),20%(1000A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6 Datasheet Product Datasheet
$75.00
$88.50 inclGST -
FPC1-32-20C-24VAC/DC, Two Pole 2 x NO Modular Contactor, 230VAC 50/60Hz, 24VAC/DC 32 Amp Coil Voltage, Hum Free
Fastron FPC1-32-20C-24VAC/DC, Two Pole 2 x NO Modular Contactor, 230VAC 50/60Hz, 24VAC/DC 32 Amp Coil Voltage, Hum Free Features 32 Amp (rms) @ 230VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FPC1-32-20C-24VAC/DC Switching Type 2 x SPST NO Approvals CE Coil Voltage 24VAC/DC Load Rating 32 Amp Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 230VAC 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Datasheet Auxiliary Contacts Selection Guide
$40.00
$47.20 inclGST -
HDR-15-5, Universal Din Rail Mount Power Supply, 85-264VAC or 120-370VDC input, 5VDC @ 2.4A output
Meanwell Universal Input HDR-15-5, Universal Din Rail Mount Power Supply, 85-264VAC or 120-370VDC input, 5VDC @ 2.4A output Supply Voltage: 85-264VAC or 120-370VDC Output Voltage: 5VDC Output Current: 2.4 Amp Short Circuit, Overload, Overcurrent, Overvoltage Protected Suited to 5VDC industrial equipment Datasheet Product Datasheet
$26.50
$31.27 inclGST -
ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%
LEM ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5% Features 125 Amp AC Current Measurement Signal Conditioned output Split Core 4-20mA Current Output Cable or Din Rail Mounting 20-28VDC Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number ATO-5-B420-D10-SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 125 Amp Output 4-20mA (Average RMS) Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -10°C / 55°C Accuracy 1.5% Termination Style 4M Output Cable Unit Weight 140g Factory Pack Qty 6 Datasheet Product Datasheet
$181.50
$214.17 inclGST -
V680E40, Varistor, 680VAC, 895VDC, E40 Package, 1130W, Equivalent to Epcos SIOV-B40K680 Features
Varsi-Raycap V680E40, 680VAC, 895VDC, E40 Package, 1130W Metal Oxide Varistor (MOV), Equivalent to Epcos SIOV-B40K680 Features Features High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Varsi-Raycap Part Number V680E40 Operating Voltage AC (50-60Hz) 680V Operating Voltage DC 895V Average Power Dissipation 1.4W Permissable Peak Current 40kA Energy Absorption(2ms) 1130W(max) Tolerance(Vn) +/- 10% Termination Style Screw Weight 73g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article GDT/MOV/TVS Tester SPD Tester
$67.90
$80.12 inclGST -
P125BDA, MiniTactor Contactor SPST-NO, 30 AMP, 1200VDC, 12VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Gigavac P126BDA, Contactor SPST-NO, 30 AMP, 1200VDC, 12VDC Coil Contactor Features Hermetically Sealed (Patented) rated to 175 Deg C High Efficiency Dual DC Coils - 12,24,48VDC options Ideal for battery powered systems or where low power is needed Built in Coils suppression for all DC Coils Small and lightweight Flexible package for installation ROHS2 Compliant Bidirectional Switching capability Specification Gigavac Part Number P126BDA Main Contact Type SPST-NO Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 30 Amp Mechanical Life @ 0 Amp 100,000 Operations Impulse Withstand 6kV rms Control Input Terminals M3 Screw Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 1200VDC Standards UL508, NEC 690.11 and 690.12 DC, ROHS2 Termination Style M4 Screw Unit Weight 90g Factory Pack Qty 1 Datasheet Product Datasheet
$139.50
$164.61 inclGST -
FP150125P, 1500/5 Amp Split Core CT, Class 0.5, 7.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
FP150125P, 1500/5 Amp Split Core CT, Class 0.5, 7.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP150125P Technology Split Core AC Clip On Current Transformer Ratio 1500/5 Aperture Size 85 x 120mm VA Rating 7.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$137.00
$161.66 inclGST -
FP050080P, 500/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP050080P, 500/5 Amp Split Core CT, Class 0.5 2.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP050080P Technology Split Core AC Clip On Current Transformer Ratio 500/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response
Magnelab DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response 10mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Magnelab Part Number DVT-1000-420 Control Output 4-20mA Input 10 - 1000VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 15 - 48VDC Voltage Isolation (1 min) 4.5kV Accuracy 1% Response Time 10mS Termination Style Screw Mounting Style DIN Rail Mount Safety UL508C, CSA C22.2 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$575.00
$678.50 inclGST