Recommended products

4098 products

  • PSD82T/16, 3 Phase Diode rectifier Bridge, 82 Amp, 1600V PSD82T/16, 3 Phase Diode rectifier Bridge, 82 Amp, 1600V

    PSD82T/16, 3 Phase Diode rectifier Bridge, 82 Amp, 1600V

    29 pcs in stock

    Powersem PSD82T/16 Three Phase Diode Rectifier Bridge, Replaces Semikron SKD62/16, equivalent to IXYS VUO 82-16 NO7 Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Powersem Part Number PSD82T/16 AC Line voltage 533V Device Configuration Three Phase Diode Rectifier Bridge DC Output @ 110 Deg C 88 Amp Package Size W:72mm L:42mm D:30mm Itsm 800 A VF(to) 0.8V Tj(max) 150°C rF 5mΩ Terminals M5 (1.5Nm) Hole Centres 60mm (M5) Gate Terminals M3 (5Nm) R th(j-c) 1.1°C/W R th(c-h) 0.52°C/W Weight 160g Isolation 3kV Factory Pack Qty 10 Certification UL Listed Powersem Headquarters Germany   Datasheet Product Datasheet Alternatives See PSD95/16 for higher rated equivalent

    29 pcs in stock

    $54.71
    $64.56 inclGST

  • Magnelab Inc DC Voltage Transducer DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response FE-DVT-1000-420

    DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response

    8 pcs in stock

    Magnelab DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response 10mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Magnelab Part Number DVT-1000-420 Control Output 4-20mA Input 10 - 1000VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 15 - 48VDC Voltage Isolation (1 min) 4.5kV Accuracy 1% Response Time 10mS Termination Style Screw Mounting Style DIN Rail Mount Safety UL508C, CSA C22.2 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet

    8 pcs in stock

    $575.00
    $678.50 inclGST

  • SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's

    SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's

    8 pcs in stock

    Fastron Electronics SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-200-5A Technology Split Core AC Current Transformer Ratio 200/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    8 pcs in stock

    $110.55
    $130.45 inclGST

  • 3-103-678, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 16Amp, 250VAC, Very High Broadband Attenuation-EMC Filter-Schurter-Fastron Electronics Store

    3-103-678, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 16Amp, 250VAC, Very High Broadband Attenuation

    18 pcs in stock

    Schurter 3-103-678, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 16Amp, 250VAC, Very High Features Line filter in standard and medical version 1-stage - standard attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Other Versions on Request Version with wire connection Version with varistor for overvoltage protection Specification Schurter Part Number 3-103-678 Rated Voltage 250V Rated Current 16A Filter Stages 1 Stage Operating Temperature -40°C to 100°C Filter Type Very High Broadband Attenuation Leakage Current 0.5mA Mounting DIn Rail Mount Mount - Case RI Material Metal Termination Style Screw Weight 140g Factory Pack Qty 10 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Isolation 1.7kV L-N VDE/UL/CSA/ROHS Yes   Datasheet Product Datasheet

    18 pcs in stock

    $60.30
    $71.15 inclGST

  • GT-D-V4-D-1, Signal Isolator/Conditioner, 0-10VDC input, 22-60VAC/DC aux, 4-20mA output GT-D-V4-D-1, Signal Isolator/Conditioner, 0-10VDC input, 22-60VAC/DC aux, 4-20mA output

    GT-D-V4-D-1, Signal Isolator/Conditioner, 0-10VDC input, 22-60VAC/DC aux, 4-20mA output

    6 pcs in stock

    Fastron Electronics GTD-D-V4-D-1(GT-D-V4-C-1), Signal Isolator/Conditioner, 0-10VDC input, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GTD-D-V4-D-1 (Formerly GT-D-V4-C-1) Control Output 4-20mA Input 0 - 10VDC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22 - 60VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    6 pcs in stock

    $219.00
    $258.42 inclGST

  • Last stock! RCS-1200-1000 0.333V, 3 Phase 1000Amp AC Measurement 4 Inch ⌀ Rogowski Coils with Integrator, Class 1

    RCS-1200-1000 0.333V, 3 Phase 1000Amp AC Measurement 4 Inch ⌀ Rogowski Coils with Integrator, Class 1

    1 pcs in stock

    RCS-1200-1000 0.333V, 3 Phase 1000Amp AC Measurement 4 Inch ⌀ Rogowski Coils with Integrator, Class 1 Flexible Current Sensor System: The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Suitable Alternative to Solar Edge CTRC-07500-1000   Specification Magnelab Part Number RCS-1200-1000 Function AC Current Measurement Nominal Measurement Current 1000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 1000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 4 Inch Coil Circumference 12 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide

    1 pcs in stock

    $790.00
    $932.20 inclGST

  • BI232-10-230VAC, Single Pole 1 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 18 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage BI232-10-240VAC, Single Pole 1 x NO SPST, 240VAC @ 32 Amp (Resistive), 24VDC @ 18 Amp Bistable Switch/Latching Relay/Relay with Manual Control, with 240VAC Coil Voltage-Bistable Switch/Latching Relay-Iskra Doo-Fastron Electronics Store

    BI232-10-230VAC, Single Pole 1 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 18 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage

    19 pcs in stock

    Iskra BI232-10-230VAC, Single Pole 1 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 18 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage Features 32 Amp (rms) @ 250VAC/18 Amp @ 24VAC/DC/10 Amp @ 48VDC/4 Amp @ 60VDC/1.2 Amp @ 110VDC/0.3 Amp @ 220VDC DIN Rail Mount Zero Power Consumption in "ON State" Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number BI232-10-230VAC Switch/Latching Relay Type 1 x SPST 250VAC/220VDC Approvals CE Coil Voltage 230VAC Load Current (RMS/DC) 32 Amp (rms) @ 250VAC/18 Amp @ 24VAC/DC/10 Amp @ 48VDC/4 Amp @ 60VDC/1.2 Amp @ 110VDC/0.3 Amp @ 220VDC Special Feature Manual and Impulse Controlled Mounting Style DIN Rail Mount Load Voltage Range 32 Amp (rms) @ 250VAC/18 Amp @ 24VAC/DC/10 Amp @ 48VDC/4 Amp @ 60VDC/1.2 Amp @ 110VDC/0.3 Amp @ 220VDC Isolation 4kV Termination Style Screw Unit Weight 60g Factory Pack Qty 20   Datasheet Relay Datasheet

    19 pcs in stock

    $42.00
    $49.56 inclGST

  • FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy

    FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy

    44 pcs in stock

    Fastron FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS521-SD-420E) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output Features Average RMS 4-20mA output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FD-420E Technology Solid Core Solid Core AC Current Transducer Range 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 4-20mA Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Installation Guide  

    44 pcs in stock

    $79.00
    $93.22 inclGST

  • 30A6B1, Hours Run Meter 90-264VAC/270-460VAC, Din Rail Mount

    30A6B1, Hours Run Meter 90-264VAC/270-460VAC, Din Rail Mount

    21 pcs in stock

    GIC Controls, 30A6B1, Hours Run Meter 90-264VAC/270-460VAC, Din Rail Mount 90-264VAC/270-460VAC 6 Digit Display 99999.9 Hours Din Rail Mount Datasheet Product Datasheet

    21 pcs in stock

    $33.48
    $39.51 inclGST

  • FPC1-32-20C-24VAC/DC, Two Pole 2 x NO Modular Contactor, 230VAC 50/60Hz, 24VAC/DC 32 Amp Coil Voltage, Hum Free

    FPC1-32-20C-24VAC/DC, Two Pole 2 x NO Modular Contactor, 230VAC 50/60Hz, 24VAC/DC 32 Amp Coil Voltage, Hum Free

    299 pcs in stock

    Fastron FPC1-32-20C-24VAC/DC, Two Pole 2 x NO Modular Contactor, 230VAC 50/60Hz, 24VAC/DC 32 Amp Coil Voltage, Hum Free Features 32 Amp (rms) @ 230VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FPC1-32-20C-24VAC/DC Switching Type 2 x SPST NO Approvals CE Coil Voltage 24VAC/DC Load Rating 32 Amp Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 230VAC 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20   Datasheet Datasheet Auxiliary Contacts Selection Guide

    299 pcs in stock

    $40.00
    $47.20 inclGST

  • Protec T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2/Open Type 1 SPD Listed, with Remote Contact

    Protec T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2/Open Type 1 SPD Listed, with Remote Contact

    47 pcs in stock

    Protec T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2/Open Type 1 SPD Listed, with Remote Contact Specifications   Raycap part number T1-1500PV-3+0-S(-R) Nominal Voltage 1500VDC No of Poles 3 Category IEC / EN / VDE Type 1, Type 2/Open Type 1 SPD Listed Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES Protective element MOV + GDT No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 12.5kA (10/350uS), 60kA(8/20uS) Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11   Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester

    47 pcs in stock

    $174.00
    $205.32 inclGST

  • GX11CAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K

    GX11CAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K

    61 pcs in stock

    Gigavac GX11CAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX11CAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1   Datasheet Product Datasheet Equivalent Parts GX11CAB  

    61 pcs in stock

    $245.00
    $289.10 inclGST

Login

Forgot your password?

Don't have an account yet?