Recommended products

4104 products

  • AI-PMUL + ART-B22-D125, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D175-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter

    ART-B22-D175-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter

    41 pcs in stock

    LEM ART-B22-D175-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number AI-PMUL + ART-B22-D175 Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    41 pcs in stock

    $540.00
    $637.20 inclGST

  • Rishabh Instruments Split Core AC Current Transformer Xmer CT Split 125/50SC 300/5 Class 1, 50 x 80mm Aperture FE-Xmer CT Split 125/50SC 300/5 Xmer CT Split 125/50SC 800/5 Class 1 10VA, 55 x 85mm Aperture

    Xmer CT Split 125/50SC 800/5 Class 1 10VA, 55 x 85mm Aperture

    9 pcs in stock

    Xmer CT Split 125/50SC 800/5 Class 1 10VA, 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Xmer CT Split 125/50SC 800/5 Class 1 10VA Technology Split Core AC Current Transformer Ratio 800/5 Aperture Size 55 x 85mm VA Rating 10VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9   Datasheet Product Datasheet

    9 pcs in stock

    $155.00
    $182.90 inclGST

  • Last stock! 3-108-713, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 50 Amp, FMAD NEO, 520VAC, Very High Attenuation 3-108-713, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 50 Amp, FMAD NEO, 520VAC, Very High Attenuation

    3-108-713, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 50 Amp, FMAD NEO, 520VAC, Very High Attenuation

    1 pcs in stock

    Schurter 3-108-713, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 50 Amp, FMAD NEO, 520VAC, Very High Attenuation Features Line filter suitable for 3 Phase + N systems Wide Temperature Range Characteristics Designed for demanding applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Suitable for use in equipment according to IEC/UL 60950 Line filter suitable for low current Inverter such as PV or battery storage systems Specification Schurter Part Number 3-108-713 Rated Voltage 520V 3 Phase Rated Current 50A Filter Stages 1 Stage Operating Temperature -40°C to 100°C Filter Type Very High Symmetrical and Asymmetrical Attenuation Leakage Current N/A Mounting Panel Mount - Case FF Material Metal Termination Style Screw Weight 1.3kg Factory Pack Qty 4 Protection Class Suitable for equipment according to IEC/UL 60950 Isolation 1.3 - 2.75kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet

    1 pcs in stock

    $223.90
    $264.20 inclGST

  • FEFC205-20-T, 2 Stage EMI (RFI) Output Sine Wave Filter [Suitable For Inverter] for 3-phase 3 wire systems, 20 Amp, 400VAC

    FEFC205-20-T, 2 Stage EMI (RFI) Output Sine Wave Filter [Suitable For Inverter] for 3-phase 3 wire systems, 20 Amp, 400VAC

    8 pcs in stock

    Fastron Electronics FEFC205-20-T, 2 Stage EMI (RFI) Output Sine Wave Filter [Suitable For Inverter] for 3-phase 3 wire systems, 20 Amp, 400VAC Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series 3 phase Output Sine wave filter with high attenuation 400VAC +10% Applications VSD Drives or Controlled Rectifiers For Industrial Applications Suitable for use in equipment according to IEC/UL 60950 Medical Version Available Specification Fastron Part Number FEFC205-20-T Rated Voltage 400V Rated Current 20A Filter Stages 2 Stage (3 Phase 3 wire) Operating Temperature -25°C to 85°C Filter Type Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering Leakage Current N/A Mounting Panel Mount - Case 32-7 Material Metal Termination Style Screw Weight 2.0kg Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 2.2kV CE Yes   Datasheet Product Datasheet  

    8 pcs in stock

    $220.00
    $259.60 inclGST

  • ProTec T1-750PV-S-M-P, ProTec Cartridge Replacement. SIDE PLUG In for T1-1500PV-3+0-S(-R)

    ProTec T1-750PV-S-M-P, ProTec Cartridge Replacement. SIDE PLUG In for T1-1500PV-3+0-S(-R)

    18 pcs in stock

    ProTec T1-750PV-S-M-P, ProTec Cartridge Replacement. SIDE PLUG In for T1-1500PV-3+0-S(-R) Specifications   Raycap part number ProTec T1-750PV-S-M-P Nominal Voltage 750VDC No of Poles 3 Category IEC / EN / VDE Type 1, Type 2/Open Type 1 SPD Listed Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES Protective element MOV + GDT No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 12.5kA (10/350uS), 60kA(8/20uS) Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11   Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester

    18 pcs in stock

    $127.50
    $150.45 inclGST

  • Power Rail 350-M2-C-0.333V, kWh Meter, 3 Phase, DIN Rail, 240VAC aux, Class 1, 0.333V input, w/ pulse output and RS485 Comms, Power quality measurements-kWh Meter-Northern Design Electronics Ltd-Fastron Electronics Store

    Power Rail PR350-M2-C-0.333V, kWh Meter, 3 Phase, DIN Rail, 240VAC aux, Class 1, 0.333V input, w/ pulse output and RS485 Comms, Power quality measurements

    9 pcs in stock

    Northern Design Power Rail PR350-M2-C-0.333V, kWh Meter, 3 Phase, DIN Rail, 240VAC aux, Class 1, 0.333V input, w/ pulse output and RS485 Comms, Power quality measurements 0.333V CT Input Optional RS 485 communication up to 19,200 bit/s True RMS values of currents and voltages Power Quality Measurements   The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, Hours Run, Peak Demand etc to the 30th Harmonic) from the measured signals.   Features : Accuracy class 1 Measurement of Active and Reactive Power Optional MODBUS RS 485 communication up to 19,200 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Northern Design Part Number Power Rail PR350-M2-C-0.333V Functions Three Phase Energy Meter Supply Voltage 230V L-N, 5 Amp +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 5 Amp +/-15% Nominal Current Input 0.333 Volt AC Pulse Output 3 x NO Voltage Free Contacts 100mA @ 100VAC/DC Tariff Input N/A (Optional) Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 106mm x 90mm x 58mm (6 modules wide) Isolation 3.5kV RS485 1200-19200 b/s Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 6 Modules Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Product Manual Product Comms Manual Option Links Application Notes CT Cable Losses Meter Accuracy at Low Current Current Input Isolation  

    9 pcs in stock

    $389.00
    $459.02 inclGST

  • FPC1-AUX-11-CTS Auxiliary Contact for FPC1 Series NON HUM FREE Contactors 1 x NO 1 x NC, 5 Amp @ 230VAC/ 1 Amp @ 130VDC. Side/Din Rail Mount

    FPC1-AUX-11-CTS Auxiliary Contact for FPC1 Series NON HUM FREE Contactors 1 x NO 1 x NC, 5 Amp @ 230VAC/ 1 Amp @ 130VDC. Side/Din Rail Mount

    120 pcs in stock

    Fastron FPC1-AUX-11-CTS Auxiliary Contact for FPC1 Series NON HUM FREE Contactors 1 x NO 1 x NC, 5 Amp @ 230VAC/ 1 Amp @ 130VDC. Side/Din Rail Mount Features UL94V0 IP20 Specification Fastron Part Number FPC1-AUX-11-CTS Switching Type 1 x SPST NO Configuration_SPST (1 x NC) Approvals CE Coil Voltage N/A Load Rating 5 Amp @ 230VAC/ 1 Amp @ 130VDC Special Feature Auxiliary Contact for NON HUM FREE Contactors Mounting Style DIN Rail Mount Load Voltage Range N/A Isolation 4kV Unit Weight 40g Factory Pack Qty 120   Datasheet Datasheet Auxiliary Contacts Selection Guide

    120 pcs in stock

    $12.50
    $14.75 inclGST

  • LEM International SA Rogowski Coil AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input and Output, up to 5000Amp Measurement, Din Rail Mount FE-Integrator AI-PMUL

    AI-P1A Universal Integrator for Rogowski Coils, Input (100 to 5000 Amp) and Output (0.333V,0.225), 1 Amp Output, Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount

    41 pcs in stock

    LEM AI-P1A Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), 1 Amp Output, Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional Input signal 1 Amp output for Power Quality Measurements up to the 32nd Harmonic (1600Hz) Accuracy Class 0.5 (IEC 61869-2) [1]. Linearity error ? 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature ?25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 0.5 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply. 24VDC Power Supply Meanwell HDR-30-24 Specification LEM Part Number AI-P1A Function Integrator and True RMS Conditioner for Rogowski Coils Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp AC Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 0.5% from 25 to 5000 Amp Current Consumption 350mA (max) Dimensions 100mm x 78mm x 15mm Mounting Din Rail Mount Integrator to Meter cable User Supplied Shielded cable 6mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet Product Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    41 pcs in stock

    $417.50
    $492.65 inclGST

  • FGM6DC-630 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1500VDC FGM6DC-630 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1500VDC

    FGM6DC-630 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1500VDC

    6 pcs in stock

    Trent FGM6DC-630 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-630 400A Functions 2 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 400 Amps @ 40 Deg C Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 1,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals TUV, CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Dimensions W98xH310xD130mm Weight 6.6kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    6 pcs in stock

    $429.00
    $506.22 inclGST

  • E62.G85-203G10, 20uF, 50x85mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 640VAC/1000VDC E62.G85-203G10, 20uF, 50x85mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 640VAC/1000VDC

    E62.G85-203G10, 20uF, 50x85mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 640VAC/1000VDC

    99 pcs in stock

    E62.G85-203G10, 20uF, 50x85mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 640VAC/1000VDC Characteristics and utility 20uF 640VAC/1000VDC Metalized Polypropylene Film Connector type - M6 x 12mm Studs M12 Stud mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E62.G85-203G10 Technology Metalized Polypropylene Film Capacitor Dimensions ø50x85mm Mounting M12 Stud Standards IEC 60831-1/2, EN 60831-1/2 Voltage 750VAC/1260VDC Operating Temperature Range -40 to 85 °C Capacitance 20uF Tolerance On Capacitance +10 / -10% Lifetime 200,000 Hours @ 85 °C (Statistical Life) Termination Style M6 x 12 studs Unit Weight 0.18kg Factory Pack Quantity 21 (MOQ = 105)   Datasheet Product Datasheet

    99 pcs in stock

    $117.00
    $138.06 inclGST

  • TRT-22D-Y-400, 22mm LED NTC Thermometer AMBER 0-100℃ 400VAC, Plastic, IP40, IEC60947-5-1

    TRT-22D-Y-400, 22mm LED NTC Thermometer AMBER 0-100℃ 400VAC, Plastic, IP40, IEC60947-5-1

    499 pcs in stock

    TRT-22D-Y-400, 22mm LED NTC Thermometer AMBER 0-100℃ 400VAC, Plastic, IP40, IEC60947-5-1 LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user. Features : 400VAC Supply 0-100℃ Measurement NTC Input LED Illumination Ø 22.5mm Cutout Long Life LED Replacement Beads Available RED, GREEN, AMBER, BLUE, or Clear\White Colour Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRT-22D-Y-400 Functions LED Frequency Meter Measurement Range 0-0-100℃ Nominal Voltage 400VAC @ 50/60Hz Impulse Voltage Wear Resistance 6kV Illumination Type Amber LED Short Circuit Protection (Fuse) Recommend 10A gG Fuse Mechanical Compression Force at Closing 20N Mechanical Compression Force at Closing 8N Humidity 35-85% Approvals CE Standards IP65, IEC60947-5-1 Weight Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Product Datasheet

    499 pcs in stock

    $14.60
    $17.23 inclGST

  • NBR-FR22GR69V20T + RT18-125L Series 20 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style-gR Semiconductor Fuse Quick Release-Trent-Fastron Electronics Store NBR-FR22GR69V20T + RT18-125L Series 20 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style-gR Semiconductor Fuse Quick Release-Trent-Fastron Electronics Store

    NBR-FR22GR69V20T + RT18-125L Series 20 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style

    38 pcs in stock

    Trent NBR-FR22GR69V20T + RT18-125L Series 20 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style Features Cylindrical Standard Fuses Sizes Wide Range of I²t Ratings up to 20 Amp Quick Release with RT18-125L fuse holder DIN Rail Mount with RT18-125L fuse holder Compatible with all 58 x 21mm fuse holders IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Solid State Relay Switchboards Bridge rectifier Fusing Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number NBR-FR22GR69V20T + RT18-125L Fuse Type I²t gR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (Pre-Arcing) 260 A²/s Nominal Current (RMS + DC) 20 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 123 x 76 x 37.5mm Fuse Holder RT18-125L Mounting Style Din Rail Mount Operating Temperature Range -40°C / 125°C Watt Loss 22.8W DC Breaking Capacity 50kA Unit Weight 60g Factory Pack Qty 10   Datasheet RT18-125L Datasheet

    38 pcs in stock

    $40.00
    $47.20 inclGST