LEM DK 100 B420, Split Core Hall Effect Current Transducer, 20, 50, 100A DC, 4-20mA unipolar output, 20-50VDC supply
Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V
Features
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 21.7mm sqr
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
DK 100 B420
Technology
DC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
20-20VDC
Nominal Current (RMS + DC)
50,75,100 Amp Selectable
Response Time
< 100ms
Output
4-20mA Analogue
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
2%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Rishabh Shunt 50A/75mV DC Current Shunt, 75mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 50A/75mV
Nominal Current Ipn (DC)
up to 50 Amp
Overload Capacity
1.2 x Ipn continuous (5 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
Rish Xmer 62-30 (40) 600/5 Class 0.2S, 6.25VA, 31mm Aperture
Features
High Accuracy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
Rish Xmer 62-30 (40) 600/5 Class 0.2S
Technology
AC Current Transformer
Ratio
600/5
Aperture Size
31x11mm (30mm)
VA Rating
6.25VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
AFP0RC14RS, Progammabel Logic Controller (PLC) 8 x On/Off inputs, 6 x Relay Outputs, 24VDC
Allow the use of the entire library of specific functions blocs of the software workshop
Expandable
Â
Datasheet
Datasheet
C100N+100R-Lugged, RC Snubber Network 275VAC, Class X2, 100uF 100 Ohm Lugged for SSR or SCR Terminal Mounting
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Product Datasheet
Iskra Doo MST-25-10, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers anre a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-10
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
6 - 10 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Alternatives
Trent FGV2 SeriesÂ
Â
Fastron Electronics GTD-2A6-A-11/SP1, Signal Isolator/Conditioner, 4-20mA Loop Supplied Input, Dual 4-20mA Outputs, 100-240VAC/DC, TROPICALIZED CIRCUIIT BOARD
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted from 4 to 20 mA DC Loop Supply (Sensor Input) to insulated 4-20mA Standard Process Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-2A6-A-11/SP1
Control Output
2 x 4-20mAÂ
Input
4-20mA Sensor Input (Loop Powered)
Special Feature
SP1 = Tropicalized Circuit Board
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent NBR-20 003 13-200A-500V-120kA-NH1, Semiconductor Type gG/gL Fuse, 200 Amp, 120kA, 500VAC, NH1, 150 x 46 x 29.5mm
Features
Square Body Size NH1
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 003 13-200A-500V-120kA-NH1
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
200 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
150 x 75 x 65mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
RCS-2400-3000 Three-Phase Flexible Current Sensor System(Rogowski Coils):
The RCS-2400 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-2400 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Â
Specification
Magnelab Part Number
RCS-2400-3000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
3000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 3000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
8 Inch
Coil Circumference
24 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Trent FGM6DC-2PL-320 320A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 320A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
320 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
CE Declaration
Trent FGM6DC-3PL-400 400A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 400 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PL-400 400A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
400 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
CE Declaration