Recommended products
-
FRI8-05/B, Current Monitoring Relay AC/DC 2-20 Amp, Adjustable Range, 8mm Aperture, Universal 24-240VAC 24VDC
Fastron FRI8-05/B, Current Monitoring Relay AC/DC 2-20 Amp, Adjustable Range, Universal 24-240VAC 24VDC FRI8-05/B Series serves to monitor AC and/or DC currents 2,4,6,8,10,12,14,16,18,20 Amp Set points up to 20 Amp, and provides Relay alarm output with Over/Undercurrent selection by jumper. Can replace Crouzet 84871122 Features : Current transducer is a part of the product. Inside this transformer there is a wire which senses the volume of fl owing current Non Invasive measurement Galvanically separates monitored circuit Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measuring current Current withstand up to 100 A Output contact: 1 x changeover/SPDT 8 A Clamp terminals 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI8-05/B Cable Aperture 8mm Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range -15 %; ? % Current Range 2 - 20 A (AC/DC 50 Hz) Current Trip Adjustment 2,4,6,8,10,12,14,16,18,20 Amp Setpoints Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 100 Amp Time delay T1 max. 500 ms Time delay T2 N/A Output CO Relay 8 Amp Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 8 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... 60C Storage temperature -30 ... 60C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Over voltage category III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Application Notes Monitoring relay FRI8-05/B serves to monitor current level in single phase AC/DC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
$94.50
$111.51 inclGST -
P115BDA, MiniTactor Contactor, 1000VDC, 50A @ 25°C, 25A @ 85°C, SPST-NO, 12V 170mA DC Coil, 100,000 Cycles, 6kV Isolation, M4 Load, M3 Coil
Gigavac P115BDA, MiniTactor Contactor, 1000VDC, 50A @ 25°C, 25A @ 85°C, SPST-NO, 12V 170mA DC Coil Contactor Features Hermetically Sealed (Patented) rated to 175 Deg C High Efficiency Dual DC Coils - 12,24,48VDC options Ideal for battery powered systems or where low power is needed Built in Coils suppression for all DC Coils Small and lightweight Flexible package for installation Specification Gigavac Part Number P115BDA Main Contact Type SPST-NO Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 50A @ 25°C, 25A @ 85°C Mechanical Life @ 0 Amp 100,000 Operations Impulse Withstand 6kV rms Control Input Terminals M3 Screw Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 1000VDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style M4 Screw Unit Weight 135g Factory Pack Qty 1  Datasheet Product Datasheet  Â
$162.03
$191.20 inclGST -
HS211, Slide on DIN Rail Heat Sink, L:80mm x W:50mm x D:50mm, 2.25°C/W
Crydom HS211, Slide on DIN Rail Heat Sink, L:80mm x W:50mm x D:50mm, 2.25°C/W Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for single or Dual SSR Black anodised for professional look Panel Mount Din Rail Mount Spec Crydom Part Number HS211 Mounting Type Din Rail Suitable SSR Rating 25 Amp Dimensions (without SSR) L:80mm x W:50mm x D:50mm Thermal Impedance 2.25°C/W Load Current @ 40 Deg C 24 Amp Load Current @ 50 Deg C 21Amp Unit Weight 220g Factory Pack Qty 10  Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$16.20
$19.12 inclGST -
A1B-22-02C, Rectifier Diode, 22Amp, 200V w/tail, M6, Cathode stud, Replaces SKR 20/02
A1B-22-02C Rectifier Diode, 22Amp, 200V w/tail, M6, Cathode stud Replaces SKR 20/02 Product Datasheet
$6.00
$7.08 inclGST -
D1D40, Solid State Relay, DC 3-32VDC control, 40A, 100VDC Load
Crydom D1D40, Solid State Relay, DC 3-32VDC control, 40A, 100VDC Load Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D1D40 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 40 Amp DC Surge Capability (10ms) 106 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent See alternative D1D40K with raised terminals for alternative or D1D80 for higher current alternative App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$131.20
$154.82 inclGST -
PMD2412PMB1-A(2).GN, Cooling Fan, Axial, 24VDC 120x120x38mm
Sunon PMD2412PMB1-A(2).GN 120x120x38mm 24VDC Fan,322.8m3/h; 54dBA; ball bearing Datasheet Product Datasheet
$45.00
$53.10 inclGST -
CY9008, Solid State Relay 660VAC 50A, 4-32VDC Control w/ Terminal Cover and LED Status Indicator. Equivalent to D2450, HD4850, HD6050
Crydom CY9008, Solid State Relay 660VAC 50A, 4-32VDC Control w/ Terminal Cover and LED Status Indicator. Equivalent to D2450G, HD4850G, HD6050G Features 50 Amp @ 24-660 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number CY9008 Switching Type Zero Crossing ROHS Yes Control Voltage 4-32VDC Load Current 50 Amp (rms) Surge Capability 597 Amp (peak) Special Feature LED Status Indicator, IP20 Terminal Cover Mounting Style Panel Mount Load Voltage Range 48-660VAC EMC Compliant Level 3 Termination Style Screw Safety Approvals CE, ROHS, REACH, Note no UL approval available Unit Weight 75g Factory Pack Qty 20 Â Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent D2450 HD4850 HD6050 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$66.00
$77.88 inclGST -
BI232-20-230VAC, Two Pole 2 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 32 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage
Iskra BI232-20-230VAC, Two Pole 2 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 32 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage Features 32 Amp (rms) @ 250VAC/18 Amp @ 24VAC/DC/10 Amp @ 48VDC/4 Amp @ 60VDC/1.2 Amp @ 110VDC/0.3 Amp @ 220VDC DIN Rail Mount Zero Power Consumption in "ON State" Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number BI232-20-230VAC Switch/Latching Relay Type 2 x SPST 440VAC/220VDC Approvals CE Coil Voltage 230VAC Load Current (RMS/DC) 32 Amp (rms) @ 440VAC/32 Amp @ 24VDC/18 Amp @ 48VDC/14 Amp @ 60VDC/5 Amp @ 110VDC/0.8 Amp @ 220VDC Special Feature Manual and Impulse Controlled Mounting Style DIN Rail Mount Load Voltage Range 32 Amp (rms) @ 440VAC/32 Amp @ 24VDC/18 Amp @ 48VDC/14 Amp @ 60VDC/5 Amp @ 110VDC/0.8 Amp @ 220VDC Isolation 4kV Termination Style Screw Unit Weight 60g Factory Pack Qty 20 Â Datasheet Relay Datasheet
$42.00
$49.56 inclGST -
SDM630MCT Modbus-CL1 V2-GROWATT-SOLAX, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms
Eastron SDM630MCT Modbus-CL1 V2-GROWATT-SOLAX, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, Special 100ms Communication Response Time 100ms Communication response time 1/5 Amp CT Input RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh)  The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.  Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Part Number SDM630MCT Modbus-CL1 V2 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (100ms Response) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C  Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility
$272.20
$321.20 inclGST -
4796.0000, IEC Appliance Outlet C20, Black, 16 Amp for 3 x 1.5m sqr/14AWG Maximum wire size 10/8mm Type
Schurter 4796.0000, IEC Appliance Outlet C20, Black, for 3 x 1.5m sqr/14AWG Maximum wire size 10/8mm Type Features Panel Mount : Snap-in Mounting from Front Side Appliance Inlet C20 Plug acc to IEC 60320-1 Screw On Mounting 70 °C pin Temperature Characteristics UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 16A, Protection Class I Other Pin versions available on request Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1  Specification Schurter Part Number 4796.0000 Rated Voltage 250V Rated Current 16A (CE) 20A (UL/CSA) Operating Temperature -25°C to 70°C Mounting Wire Screw Mount/Outlet Material Thermoplastic, black, UL 94V-0 Termination Style C20/Screw Terminal Weight 40g Factory Pack Qty 1 Protection Class From front side IP30 acc. to IEC 60529 Isolation 2kV VDE/UL/CSA/CE/ROHS Yes  Datasheet Product Datasheet
$15.09
$17.81 inclGST -
SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F36-500-5A Technology Split Core AC Current Transformer Ratio 500/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
RI61J C 32-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 32 Amp, 220VDC, 10kA
Iskra Doo RI61J C 32-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 32 Amp, 220VDC, 10kA Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Iskra Doo Part Number RI61J C32 Functions 1 Pole MCB - C Curve Nominal Voltage 220VDC Nominal Current Range 32 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Rated Operations 10,000 Ops Surge Current 220V Short Circuit Current 10kA Approvals VDE, GOST-R Standards IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ; Weight 130g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$19.95
$23.54 inclGST