Low Voltage Switchgear
-
FGV2-M06, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal and Magnetic Release
Trent FGV2-M06, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M06 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1 - 1.6 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$62.00
$73.16 inclGST -
FGV2-M07, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal and Magnetic Release
Trent FGV2-M07, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M07 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1.6 - 2.5 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$62.00
$73.16 inclGST -
FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release
Trent FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M08 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.3 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$62.00
$73.16 inclGST -
FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release
Trent FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives
$62.00
$73.16 inclGST -
FGS1-C/2-440-20, 440VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/2-440-20, 440VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/2-440-20 Nominal Voltage 440VAC No of Poles 2 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$60.00
$70.80 inclGST -
FGS1-C/2-385-20, 385VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/2-385-20, 385VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/2-385-20 Nominal Voltage 385VAC No of Poles 2 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$60.00
$70.80 inclGST -
FGS1-C/2-320-20, 320VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/2-320-20, 320VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/2-320-20 Nominal Voltage 320VAC No of Poles 2 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$60.00
$70.80 inclGST -
FGS1-C/2-275-20, 275VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/2-275-20, 275VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/2-275-20 Nominal Voltage 275VAC No of Poles 2 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$60.00
$70.80 inclGST -
3-146-121 (T12-121SR-8), 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts & Indicator Tag
Schurter, 3-146-121 (T12-121SR-8), 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts & Indicator Tag Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Indicator Ribbon/Tag Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 3-146-121 (T12-121SR-8) Functions 1 Pole Thermal Circuit Breaker Button Action Manual ON/OFF Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$59.70
$70.45 inclGST -
F-ASW-A01B, Manual Battery Switch, DPST 300 Amp 24VDC, Flange Mount 120mm Wide, M10 Terminations, IP67/IEC529
Free Aus Post Shipping for $300 spendF-ASW-A01B, Manual Battery Switch, DPST 300 Amp 24VDC, Flange Mount 120mm Wide, M10 Terminations, IP67/IEC529 DC battery switches are designed to be placed in between the battery and load. Suitable for any low voltage DC application which requires up to 2kA overload for 1.5 minutes. Features : 1 Pole Disconnect Suitable for DC Isolation Standards : IEC 60364-7-712 IP65 (Front) IP20 (Terminals) Specification Fastron Part Number F-ASW-A01B Functions 1 Pole DC DPST Disconnect Switch, ON/OFF Red Lever Nominal Voltage 24/32VDC Nominal Current 1 x 300 Amp DC, 1 x 500 Amp (5 seconds) Rated Impulse Voltage 2kV (1 min) Rated Insulation Voltage 100 Mohm @ 500VDC Short Circuit Current 2kA (1.5 min), 2.5kA (10s) Mounting Outdoor/Indoor Panel Mount Panel Size N/A Standards PA66.94V-0 Termination M10 Protection Class IP44 Weight 500g Enclosure Material Zytel Factory Pack Qty 100 Datasheet Product Datasheet
-
4410.0106 T12-211S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts
churter, 4410.0106 T12-211S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0147 (T12-221S-10) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
3-137-183 T12-121S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts
Schurter, 3-137-183 T12-121S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 3-137-183 (T12-121S-8) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST