Low Voltage Switchgear
-
4410.0695 T12-221S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts
Free Aus Post Shipping for $300 SpendSchurter, 4410.0695 T12-221S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0695 (T12-221S-8) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
4410.0147 T12-221S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts
Free Aus Post Shipping for $300 SpendSchurter, 1 Pole 10 Amp, 1kA Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/Auxiliary Contacts 4410.0147 T12-221S-10 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0147 (T12-221S-10) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
4410.0084 T12-211S-1, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 1 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 0.8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0084 T12-211S-1 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0084 T12-211S-1 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 1 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
4410.0215 T12-221S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contact
Schurter, 4410.0215 T12-221S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contact Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0215 T12-221S-2 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Manual ON/OFF Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 2 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
4410.0131 T12-211S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0131 T12-211S-8 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0131 T12-211S-8 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
4410.0439 T12-211S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0439 T12-211S-2 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0439 T12-211S-2 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 2 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
4410.0044 T12-211S-0.8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 0.8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 0.8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0044 T12-211S-0.8 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0044 T12-211S-0.8 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 0.8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
FRS4-C40 320V 2P (2+0) (R), Class II/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 20/50kA L-N, 230VAC, DIN Rail Mount, L/N-PE, High Energy MOV Type
Free Aus Post Shipping for $300 SpendTrent FRS4-C40 320V 2P (2+0) (R), Class II/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 20/50kA L-N, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, L/N-PE, High Energy MOV Type Specifications Trent part number FRS4-C40 320V 2P (2+0) (R) Nominal Voltage (Un) 230VAC Maximum Operating Voltage (Uc) 320VAC Voltage Protection Level (Up) <1.5kV No of Poles 2 Category IEC / EN / VDE Class II / Type 2 Location of use Sub Distribution Boards Protection modes L/N-PE, High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 40kA(8/20us) L/N-PE 320VAC Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
4410.0826 T12-111S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts
Free Aus Post Shipping for $300 spendSchurter 4410.0826 T12-111S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description 40mm Panel Mount Type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0826 T12-111S-10 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Mounting Panel Mount 40mm hole centres Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
4410.0711 T12-111S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts
Free Aus Post Shipping for $300 spendSchurter 4410.0711 T12-111S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description 40mm Panel Mount Type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0711 T12-111S-8 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Mounting Panel Mount 40mm hole centres Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
P-3L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. 3 Phase, 27 Way, 80 Amp 8mm
P-3L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. 3 Phase, 27 Way, 80 Amp 8mm
$49.00
$57.82 inclGST -
ISPRO CR 40/440, Class II / Type 2 / C, Modular Surge Protection Device (SPD) with Remote Contacts, 1 Pole 40kA, 440VAC, DIN Rail Mount. For Sub Distribution Boards
Iskra ISPRO CR 40/440, Class II / Type 2 / C, Modular Surge Protection Device (SPD) with Remote Contacts, 1 Pole 40kA, 440VAC, DIN Rail Mount. For Sub Distribution Boards Specifications Iskra Doo part number ISPRO CR 40/440 Nominal Voltage 440VAC No of Poles 1 (modular, stackable) Category IEC / EN / VDE Class II / Type 2 / C Location of use Sub Distribution Boards Additional Remote Contacts YES Protection modes L/N-PE Protective element MOV Surge discharge rating Imax up to 40 kA Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
$48.00
$56.64 inclGST