Low Voltage Switchgear

163 products

  • Last stock! MST-25-1.6, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-1.6, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal Release Only

    1 pcs in stock

    Iskra Doo MST-25-1.6, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-1.6 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1 - 1.6 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    1 pcs in stock

    $69.00
    $81.42 inclGST

  • Last stock! MST-25-2.5, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-2.5, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal Release Only

    1 pcs in stock

    Iskra Doo MST-25-2.5, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-2.5 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1.6 - 2.5 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    1 pcs in stock

    $69.00
    $81.42 inclGST

  • MST-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal Release Only

    Out of stock , More available in 4-6 weeks

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MST-25-6.3, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-6.3 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock , More available in 4-6 weeks

    Free Aus Post Shipping for $300 Spend

    $69.00
    $81.42 inclGST

  • FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    120 pcs in stock

    Trent FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M21 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 17 - 23 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    120 pcs in stock

    $68.00
    $80.24 inclGST

  • FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release

    56 pcs in stock

    Trent FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 28 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 13 - 18 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    56 pcs in stock

    $68.00
    $80.24 inclGST

  • FGV2-M16, Motor Protection Switch, 3 Phase, 690VAC, 9 - 14 Amp Setting Range, Thermal and Magnetic Release FGV2-M16, Motor Protection Switch, 3 Phase, 690VAC, 9 - 14 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M16, Motor Protection Switch, 3 Phase, 690VAC, 9 - 14 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M16, Motor Protection Switch, 3 Phase, 690VAC, 9 - 14 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M16 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 9 - 14 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives  

    59 pcs in stock

    $65.00
    $76.70 inclGST

  • FGV2-M14, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal and Magnetic Release FGV2-M14, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M14, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal and Magnetic Release

    54 pcs in stock

    Trent FGV2-M14, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M14 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 6 - 10 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives  

    54 pcs in stock

    $65.00
    $76.70 inclGST

  • FGV2-M01, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release FGV2-M01, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M01, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Trent FGV2-M01, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M01 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0 - 0.16 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $62.00
    $73.16 inclGST

  • FGV2-M02, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release FGV2-M02, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M02, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Trent FGV2-M02, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M02 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.16 - 0.25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $62.00
    $73.16 inclGST

  • FGV2-M03, Motor Protection Switch, 3 Phase, 690VAC, 0.25 - 0.4 Amp Setting Range, Thermal and Magnetic Release FGV2-M03, Motor Protection Switch, 3 Phase, 690VAC, 0.25 - 0.4 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M03, Motor Protection Switch, 3 Phase, 690VAC, 0.25 - 0.4 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Trent FGV2-M03, Motor Protection Switch, 3 Phase, 690VAC, 0.25 - 0.4 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M03 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.25 - 0.4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $62.00
    $73.16 inclGST

  • FGV2-M04, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release FGV2-M04, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M04, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Trent FGV2-M04, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M04 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.4 - 0.63 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $62.00
    $73.16 inclGST

  • FGV2-M05, Motor Protection Switch, 3 Phase, 690VAC, 0.63 - 1 Amp Setting Range, Thermal and Magnetic Release FGV2-M05, Motor Protection Switch, 3 Phase, 690VAC, 0.63 - 1 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M05, Motor Protection Switch, 3 Phase, 690VAC, 0.63 - 1 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Trent FGV2-M05, Motor Protection Switch, 3 Phase, 690VAC, 0.63 - 1 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M05 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.63 - 1 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $62.00
    $73.16 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account