Low Voltage Switchgear
-
FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp
Trent FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN20 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp
Trent FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN11 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp
Trent FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU400 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 385-415VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp
Trent FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU225 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 220-240VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
35mm DIN Rail 1M, 35mm Busbar, 1M Long
35mm DIN Rail 1M, 35mm Busbar, 1M Long
$8.00
$9.44 inclGST -
4400.0405, TZZ01 IP54 Dust Cover for T11 CBE Series
4400.0271 T11-211-6.5, Thermal 4400.0405, TZZ01 IP54 Dust Cover for T11 CBE Series Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type IP54 Dust Cover for T11 Series Datasheet Product Datasheet
$6.59
$7.78 inclGST -
EC-P-3L, End Cap for 3 Phase P-3L Type Busbar
EC-P-3L, End Cap for 3 Phase P-3L Type Busbar
$0.50
$0.59 inclGST