  • 93.34.43.100.0, Feet fixing kit for use with LEM LTC 200/350/400/500-S

    93.34.43.100.0, Feet fixing kit for use with LEM LTC 200/350/400/500-S

    46 pcs in stock

    Feet fixing kit for use with LEM LTC 200/350/400/500-S Product Datasheet

    46 pcs in stock

    $27.60
    $32.57 inclGST

  • Last stock! LEM International SA AC/DC Current Hall Effect Sensor LTC 200-S, C/L Hall Effect Current Sensor, 200 Amp, 200mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.5%, ø27.5mm FE-LTC200-S

    LTC 200-S, C/L Hall Effect Current Sensor, 200 Amp, 200mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.5%, ø27.5mm

    2 pcs in stock

    LEM LTC Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 400 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 200-S Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 400 Amp Output 200 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 300g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details

    2 pcs in stock

    $438.20
    $517.08 inclGST

  • LTC 400-S, C/L Hall Effect Current Sensor, 400 Amp, 80mA Out, Panel Mount

    LTC 400-S, C/L Hall Effect Current Sensor, 400 Amp, 80mA Out, Panel Mount

    Out of stock

    LEM LTC Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar(not show) and Feet Kit(not shown) to replace LA 400-T Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 400-SF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Measurement Range +/- 1000 Amp Output 80 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details

    Out of stock

    $481.90
    $568.64 inclGST

  • LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply

    LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply

    Out of stock

    LEM LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-S Technology Closed Loop Hall Effect Aperture 102mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 4000 Amp Measurement Range +/- 6000 Amp Output 800 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $2,853.20
    $3,366.78 inclGST

  • Last stock! LEM International SA AC/DC Current Hall Effect Sensor PCM 30-P, Pointsenz Railway DC Current Sensor, 30 Amp, 4-20mA Output FE-PCM30-P

    PCM 30-P, Pointsenz Railway Bipolar DC Current Sensor, 30 Amp, Bipolar 4-20mA Output

    4 pcs in stock

    LEM PCM 30-P Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 30-P Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 30 Amp Measuring Range +/- 60 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    4 pcs in stock

    $760.00
    $896.80 inclGST

  • Last stock! PCM 20-P, Pointsenz Railway Bipolar DC Current Sensor, 20 Amp, Bipolar 4-20mA Output

    PCM 20-P, Pointsenz Railway Bipolar DC Current Sensor, 20 Amp, Bipolar 4-20mA Output

    2 pcs in stock

    LEM PCM 20-P Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 20-P Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 20 Amp Measuring Range +/- 40 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    2 pcs in stock

    $733.30
    $865.29 inclGST

  • LF 2005-S, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply

    LF 2005-S, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply

    Out of stock

    LEM LF 2005-S, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 2005-S Technology Closed Loop Hall Effect Aperture ø60.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.3% Termination Style Molex 6410 Unit Weight 1.5kg Factory Pack Quantity 9   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $941.90
    $1,111.44 inclGST

  • HTA 250-S/SP3, O/L Hall Effect Current Sensor, 250 Amp, +/-4V Output

    HTA 250-S/SP3, O/L Hall Effect Current Sensor, 250 Amp, +/-4V Output

    Out of stock

    LEM HTA Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 250-S Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 250 Amp Measurement Range +/-750 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $303.60
    $358.25 inclGST

  • HAT 300-S, O/L Current Transducer, 300 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 300-S, O/L Current Transducer, 300 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    Out of stock

    LEM HAT 300-S, O/L Hall Effect Current Transducer, 300 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 300-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-900 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $128.00
    $151.04 inclGST

  • LT 1005-S, C/L Current Transducer,Ipn = 1000A, +/-15/24VDC, 200mA output, X = 0.4%

    LT 1005-S, C/L Current Transducer,Ipn = 1000A, +/-15/24VDC, 200mA output, X = 0.4%

    Out of stock

    LEM LT 1005-S Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 150kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 200 mA Isolation 6 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 850g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $626.80
    $739.62 inclGST

  • HASS 50-S, O/L Hall Effect Current Sensor, Panel Mount, 50 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr

    HASS 50-S, O/L Hall Effect Current Sensor, Panel Mount, 50 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr

    15 pcs in stock

    LEM HASS 50-S Series Open Loop AC/DC Hall Effect Sensor Features 5VDC Unipolar Supply Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HASS 50-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/-150 Amp Output 2.5 Vref Isolation 3.3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    15 pcs in stock

    $46.00
    $54.28 inclGST

  • HAT 500-S, O/L Hall Effect Current Transducer, 500 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 500-S, O/L Hall Effect Current Transducer, 500 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    15 pcs in stock

    LEM HAT 500-S, O/L Hall Effect Current Transducer, 500 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 500-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 500 Amp Measurement Range +/-2250 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    15 pcs in stock

    $120.00
    $141.60 inclGST