Hall Effect Current Sensors Panel/Busbar/Cable Mount
-
HAC 400-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr
HAC 400-S O/L Hall Effect Current Sensor, 400 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAC 400-S Technology Open Loop Hall Effect Aperture 24 x 16mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Overload Capability +/- 1200 Amp Output +/-4 V Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04AG Unit Weight 70g Factory Pack Quantity 10 Datasheet Product Datasheet
$155.30
$183.25 inclGST -
HAC 300-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr
HAC 300-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, PanelMount 24 x 16mm sqr Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift 2500V Isolation Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 800 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAC 300-S Technology Open Loop Hall Effect Aperture 24 x 16mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Overload Capability +/- 900 Amp Output +/-4 V Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04AG Unit Weight 70g Factory Pack Quantity 10 Datasheet Product Datasheet
$155.30
$183.25 inclGST -
93.34.61.200.0, Busbar Fixing KIT for LTC 600/1000
LEM 93.34.61.200.0 Busbar Fixing KIT for LTC 600/1000 (M5x25) Product Datasheet
$40.30
$47.55 inclGST -
LTC 600-S/SP2, C/L Hall Effect Current Sensor, 600 Amp, 200mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%
LEM LTC 600-S/SP2 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-S/SP2 Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 200 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
$486.50
$574.07 inclGST -
LT 1005-S/SP4, C/L Current Transducer, Ipn = 1000A, +/-15/24VDC, 250mA Output, X = 0.4%
LEM LT 1005-S/SP4 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S/SP4 Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 250 mA Isolation 12 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 850g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$983.10
$1,160.06 inclGST -
LTC 600-SF, C/L Hall Effect Current Sensor, 400 Amp, 100mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%
LEM LTC 600-SF Closed Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-SF Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
$511.80
$603.92 inclGST -
LTC 400-SF, C/L Hall Effect Current Sensor, 400 Amp, 80mA Output
LEM LTC Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar(not show) and Feet Kit(not shown) to replace LA 400-T Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 400-SF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Measurement Range +/- 1000 Amp Output 80 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 400g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
$496.80
$586.22 inclGST -
LTC 200-SF/SP2, C/L Hall Effect Current Sensor, 200 Amp, 200mA Out, +/-15..24VDC, Panel Mount, X = 0.5%, ø27.5mm
LEM LTC 200-SF/SP2, C/L Hall Effect Current Sensor, 200 Amp, 200mA Out, +/-15..24VDC, Panel Mount, X = 0.5%, ø27.5mm Features Bipolar and insulated current measurement up tp 400 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 200-SF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 400 Amp Output 200 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 300g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
$516.40
$609.35 inclGST -
HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply
LEM HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide current ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 20000-SB Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 20000 Amp Overload Rating 30000 At Output +/-10 V Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$4,481.00
$5,287.58 inclGST -
LTC 600/SP02A(LA600-T), C/L Hall Effect Current Sensor, 600 Amp, 100mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.7%
LEM LTC 600/SP02A(LA600-T) Open Loop AC/DC Hall Effect Sensor Features To replace LA 600-T Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar and Feet Kit(not shown) Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600/SP02A(LA600-T) Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
$770.50
$909.19 inclGST -
LTC 600-S, C/L Hall Effect Current Sensor, 400 Amp, 100mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%
LEM LTC 600-S Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-S Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
$741.80
$875.32 inclGST -
HASS 100-S, O/L Hall Effect Current Sensor, Panel Mount, 100 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr
LEM HASS 100-S Series Open Loop AC/DC Hall Effect Sensor Features 5VDC Unipolar Supply Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HASS 100-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 100 Amp Measurement Range +/-300 Amp Output 2.5 Vref Isolation 3.3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$39.90
$47.08 inclGST