DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing
0-400/600 Amp Shunt Measurement Options (Included)
Bi-Directional DC Measurement
Voltage Measurement Range 150V to 1150V
Backlit LCD
12VDC to 24VDC Supply Voltage
Meter Operating Temperature -25°C to 70°C
Sensor Operating temperature -40°C to 85°C
Busbar Operating temperature 105°C max
IP Enabled with DHCP
12 - 24VDC Supply
Accuracy Class B
The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands.
Features :
Measurement of DC kWh Power
Graphic LCD with illumination
Specification
LEM Part Number
DCBM400, DCBM600
Functions
DC Energy Meter
Supply Voltage
12-24VDC
Nominal Measurement Range
150VDC to 1000VDC
Maximum Measurement Range
150 - 1150VDC
Nominal Current Input
Shunt Provided
IP Conficguration
Fixed or DHCP
Accuracy
Class B
Mounting
Din Rail Mount
Real Time Clock
NTP Time Sync over HTTPS/REST
Dimensions
96 x 96 x 82mm (2 DIN)
Pulse Output
Optional
Isolation
1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m
Comms
HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data
Weight
5/6kg
Certification
PTB, VDE-AR-E-2418-3-100
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Operating Temperature
-25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C )
Â
Datasheet
Product Datasheet
Leaflet
Â
DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes
0-650 Amp Shunt Measurement
Bi-Directional DC Measurement
Voltage Measurement Range 150V to 1000V
Backlit LCD
9-40VDC Aux Supply Voltage
Meter Operating Temperature -25°C to 70°C
Sensor Operating temperature -40°C to 85°C
Busbar Operating temperature 105°C max
Accuracy Class B
The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands.
Features :
Measurement of DC kWh Power
Dot Matrix LCD with illumination
Specification
Eastron Part Number
DCM650-H
Functions
DC Energy Meter
Supply Voltage
9-40VDC
Nominal Measurement Range
150VDC to 1000VDC
Maximum Measurement Range
150 - 1000VDC
Nominal Current Input
Shunt Provided
IP Conficguration
Fixed or DHCP
Accuracy
Class B
Mounting
Din Rail Mount
Real Time Clock
N/A
Dimensions
103 x 104 x 64mm
Pulse Output
Optional
Isolation
1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m
Comms
3 x RS485 Modbus RTU 4800-115200bps (192000bps default)
Weight
5/6kg
Certification
PTB, VDE-AR-E-2418-3-100
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Operating Temperature
-25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C )
Â
Datasheet
Product Datasheet
EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply
Dte and Time stamped
Events
Train Identification Numbers
Absolute energy values for consumption and regeneration of active and reactive energy
Backlit LCD
24-110VDC Aux Supply Voltage
measurement of 16.7Hz, 50Hz, 60Hz, or DC energy
User load profile and location storedÂ
Voltage detect feature
Meter Operating Temperature -40°C to 70°C
Sensor Operating temperature -40°C to 85°C
Busbar Operating temperature 105°C max
Accuracy Class B
The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands.
Features :
Measurement of DC kWh Power
Dot Matrix LCD with illumination
Specification
Eastron Part Number
DCM650-H
Functions
DC Energy Meter
Supply Voltage
9-40VDC
Nominal Measurement Range
AC:70-300V or 17.9 - 100mAÂ DC:17.9 - 100mA
Maximum Measurement Range
6400V via DV 6400 Hall Sensor
Nominal Current Input
Via external Current Transformer 1-5 Amp rms or 25-1000mA, DC: 25-2000mA via external Hall Sensor
Comms
RS232/RS485(RS422) according to EN 50463-3 and IEC 62056-21
Accuracy
Class 0.5R
Mounting
Panel Mount
Real Time Clock
Yes / time stamped data
Sampling interval
4800Hz
Dimensions
165 x 289 x 70 mm (W x H x D)
GPS / GSM
GPS receiver as standard / GSM via external 3rd party Modem
Isolation
1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m
Comms
3 x RS485 Modbus RTU 4800-115200bps (192000bps default)
Weight
1.5kg
Standards
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Operating Temperature
-40 →+70°C (Meter), -40 →+85 °C
Â
Datasheet
Product Datasheet
User Manual
TEMA 4G User Guide
SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers
Â
Features
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
2Â x Pulse Outputs (2 x configurable)
Â
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM54-MODBUS-MID
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
500V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2Â x Passive (Configurable)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Â
Eastron Europe SDM72CT-D, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers
Â
Features
Â
3 x 1/5 Amp CT Input
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages. Note only kWH is shown on display
1Â x Pulse Outputs (fixed)
Â
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM72CT-D
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 5000 Amp
Maximum Measurement Range
500V L-L 230V L-N, 5000 Amp
Nominal Current Input
CT Connect 3 x 5/1 Amp
Pulse Output
1Â x Passive (fixed)
Tariff Input
N/A
Accuracy
Class 1 (kWh Only)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
Alternatives
SDM630MCT
SDM72CT-M (with additional measurement parameters)
Modbus Utility
EEM Meter Setting Software Utility
Â
Eastron Europe SDM72CT-M, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers
Â
Features
Â
3 x 1/5 Amp CT Input
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
1Â x Pulse Outputs (fixed)
Â
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM72CT-M
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 5000 Amp
Maximum Measurement Range
500V L-L 230V L-N, 5000 Amp
Nominal Current Input
External CT Connect 3 x 1/5 Amp
Pulse Output
1Â x Passive (fixed)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Alternatives
SDM630MCT
Modbus Utility
EEM Meter Setting Software Utility
Â
Eastron Europe SDM72D-M-2-MID, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers, (Superseeds SDM72D-M V2)
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
1Â x Pulse Outputs (fixed)
Â
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM72D-M-2-MID (Superseeds SDM72D-M V2)
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
500V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
1Â x Passive (fixed)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Â