kWh Meters for Ralways or EV chargers

7 products

  • DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes-DC kWh Meter-LEM International SA-Fastron Electronics Store

    DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes

    Out of stock

    DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C )   Datasheet Product Datasheet Leaflet  

    Out of stock

    $1,700.00 - $2,500.00

  • DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes

    DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes

    Out of stock

    DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes 0-650 Amp Shunt Measurement Bi-Directional DC Measurement Voltage Measurement Range 150V to 1000V Backlit LCD 9-40VDC Aux Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Dot Matrix LCD with illumination Specification Eastron Part Number DCM650-H Functions DC Energy Meter Supply Voltage 9-40VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1000VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock N/A Dimensions 103 x 104 x 64mm Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms 3 x RS485 Modbus RTU 4800-115200bps (192000bps default) Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C )   Datasheet Product Datasheet

    Out of stock

    $1,495.00
    $1,764.10 inclGST

  • EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply

    EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply

    Out of stock

    EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply Dte and Time stamped Events Train Identification Numbers Absolute energy values for consumption and regeneration of active and reactive energy Backlit LCD 24-110VDC Aux Supply Voltage measurement of 16.7Hz, 50Hz, 60Hz, or DC energy User load profile and location stored  Voltage detect feature Meter Operating Temperature -40°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Dot Matrix LCD with illumination Specification Eastron Part Number DCM650-H Functions DC Energy Meter Supply Voltage 9-40VDC Nominal Measurement Range AC:70-300V or 17.9 - 100mA  DC:17.9 - 100mA Maximum Measurement Range 6400V via DV 6400 Hall Sensor Nominal Current Input Via external Current Transformer 1-5 Amp rms  or 25-1000mA, DC: 25-2000mA via external Hall Sensor Comms RS232/RS485(RS422) according to EN 50463-3 and IEC 62056-21 Accuracy Class 0.5R Mounting Panel Mount Real Time Clock Yes / time stamped data Sampling interval 4800Hz Dimensions 165 x 289 x 70 mm (W x H x D) GPS / GSM GPS receiver as standard / GSM via external 3rd party Modem Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms 3 x RS485 Modbus RTU 4800-115200bps (192000bps default) Weight 1.5kg Standards Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -40 →+70°C (Meter), -40 →+85 °C   Datasheet Product Datasheet User Manual TEMA 4G User Guide

    Out of stock

    $11,800.00
    $13,924.00 inclGST

  • SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers

    SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers

    9 pcs in stock

    SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers   Features 3 x 100 amp Direct Connect RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages 2 x Pulse Outputs (2 x configurable)   The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.   Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM54-MODBUS-MID Functions Three Phase Energy Meter Supply Voltage N/A Nominal Measurement Range 415V L-L 230V L-N, 100 Amp Maximum Measurement Range 500V L-L 230V L-N, 100 Amp Nominal Current Input Direct connect 3 x 100 Amp Pulse Output 2 x Passive (Configurable) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C   Documents Product Datasheet User Manual Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility  

    9 pcs in stock

    $269.00
    $317.42 inclGST

  • Last stock! SDM72CT-D, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers

    SDM72CT-D, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers

    5 pcs in stock

    Eastron Europe SDM72CT-D, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers   Features   3 x 1/5 Amp CT Input RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages. Note only kWH is shown on display 1 x Pulse Outputs (fixed)   The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.   Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM72CT-D Functions Three Phase Energy Meter Supply Voltage N/A Nominal Measurement Range 415V L-L 230V L-N, 5000 Amp Maximum Measurement Range 500V L-L 230V L-N, 5000 Amp Nominal Current Input CT Connect 3 x 5/1 Amp Pulse Output 1 x Passive (fixed) Tariff Input N/A Accuracy Class 1 (kWh Only) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C   Documents Product Datasheet Alternatives SDM630MCT SDM72CT-M (with additional measurement parameters) Modbus Utility EEM Meter Setting Software Utility  

    5 pcs in stock

    $219.00
    $258.42 inclGST

  • SDM72CT-M, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect inpuw/ 1 x fixed pulse output, S485 Comms, MID Approved. Built for EV Chargers

    SDM72CT-M, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect inpuw/ 1 x fixed pulse output, S485 Comms, MID Approved. Built for EV Chargers

    16 pcs in stock

    Eastron Europe SDM72CT-M, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers   Features   3 x 1/5 Amp CT Input RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages 1 x Pulse Outputs (fixed)   The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.   Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM72CT-M Functions Three Phase Energy Meter Supply Voltage N/A Nominal Measurement Range 415V L-L 230V L-N, 5000 Amp Maximum Measurement Range 500V L-L 230V L-N, 5000 Amp Nominal Current Input External CT Connect 3 x 1/5 Amp Pulse Output 1 x Passive (fixed) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C   Documents Product Datasheet User Manual Alternatives SDM630MCT Modbus Utility EEM Meter Setting Software Utility  

    16 pcs in stock

    $259.00
    $305.62 inclGST

  • SDM72D-M-2-MID, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers SDM72D-M-2-MID, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers

    SDM72D-M-2-MID, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers

    Out of stock

    Eastron Europe SDM72D-M-2-MID, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers, (Superseeds SDM72D-M V2) 3 x 100 amp Direct Connect RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages 1 x Pulse Outputs (fixed)   The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.   Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM72D-M-2-MID (Superseeds SDM72D-M V2) Functions Three Phase Energy Meter Supply Voltage N/A Nominal Measurement Range 415V L-L 230V L-N, 100 Amp Maximum Measurement Range 500V L-L 230V L-N, 100 Amp Nominal Current Input Direct connect 3 x 100 Amp Pulse Output 1 x Passive (fixed) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C   Documents Product Datasheet User Manual Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility  

    Out of stock

    $217.00
    $256.06 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account