GIC Controls, LD17F1 10-80VDC, Hours Run Meter 10-80VAC, 48x48mm Panel Mount
Features
IP40 (IP66 with Gasket)
10-80VDC
6 Digit Display
99999.9 Hours
48x48mm Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
Trent I²t Semiconductor Fuse, NBR-FWP-600A 700V AC/DC, Semiconductor Fuse, 600 Amp, 700VAC/DC, Round Barrel 7.09 x 2.0 x 2.5 Inches. Clearing I2t 250kA, Breaking Capacity 200kAand Microswitch
Features
Square Body DIN 43 653
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Fuse Blown Indicator and Microswitch
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FWP-600A 700V AC/DC
Fuse Type
I²t AR Class
Nominal Voltage
700VAC @ 50Hz
I²t Rating (660V)
250000A²/s
Nominal Current (RMS + DC)
600 Amp
Tested Breaking Capacity
200kA @ 700VAC/DC
Dimensions
138 x 61 x 50mm
Hole Centers
108mm +
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
75W
Termination Style
M10
Unit Weight
350g
Factory Pack Qty
10
Datasheet
Product Datasheet
GIC Controls, LA21F1 90-264VAC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount
Features
IP40 (IP66 with Gasket)
90-264VAC
6 Digit Display
99999.9 Hours
37x24mm Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
M3 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V (For Non Insulated Busbar or wire)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
For Non Insulated or Insulated Busbar/ Bare Wire
Rated System Voltage 0.6/3kV (1 Min) NOTE: 30V only with Non Insulated cables, see M2 for 600V Insulated types.
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M3.10.2mA,M3.100.0.1V,M3.100.100mA,M3.100.1A,M3.100.1V,
M3.200.1A,M3.200.2V,M3.UM.1A.1V,M3.UM.50A.1V,M3.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz (customised on request)
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
M4 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V for Busbar/Bare Wire
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
600V Insulation (3kv/1min)
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M4.10.2mA,M4.100.0.1V,M4.100.100mA,M4.100.1A,M4.100.1V,
M4.200.1A,M4.200.2V,M4.UM.1A.1V,M4.UM.50A.1V,M4.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
H7 Heatsink Profile 72.5mm x 140mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
DRG-01 (Generic 35mm DIN Rail Adaptor), UL94V0 DIN Rail Clips for Converting Panel Mount devices, Includes 2 mounting screws and 2 side clips, F2.90.98.000.1
SPD1-DC/3-1500/40, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2
Specifications
Trent part number
T1-1500PV-3+0-S(-R)
Nominal Voltage
1500VDC
No of Poles
3
Category IEC / EN / VDE
Type 2
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC50539-11 (TUV Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
SPD1-DC/3-1000/40, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA
Specifications
Trent part number
SPD1-DC/3-1000/40
Nominal Voltage
1000VDC
No of Poles
3
Category IEC / EN / VDE
Type 2
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV, IP40
Weight
420g
Standards
IEC50539-11 (TUV Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Risbabh EMDC 6002-1000-HA-C-4R, 4 Channel DC kWh Meter, Class 0.5, 150-150mV Shunt input, 201-1000VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, 4 Line LCD Display, 60-300VAC/DC Aux Supply, Internal Logging, 4 x Configurable Relay Alarms
4 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 201-1000VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EMDC 6002-1000-HA-C-2R
Functions
4 Channel DC kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
201-1000VDC
Maximum Measurement Range
201-1000VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Trent A100P1000-4, Amptrap Semiconductor Fuse, 1000 Amp, 750VAC/1000VDC, Form 101, 100kA, Name Brand Replacement
Features
Square Body DIN 43 653
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-A100P1000-4
Fuse Type
I²t AR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (660V)
Nominal Current (RMS + DC)
1000 Amp
Tested Breaking Capacity
100kA @ 750VAC/1000VDC
Dimensions
209 x 85.9mm
Hole Centers
148-167mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
125W
Termination Style
M10
Unit Weight
1500g
Factory Pack Qty
10
Datasheet
Product Datasheet