Fastron FRTD-Transmitter-0-400-420-24, Pt100 , 4-20mA Transmitter, 0 to 400 Deg C, 24VDC Supply
Class A Accuracy
Steel Insulated Cable
Low Long Term Drift
Rated for 0 to 220 Deg C Max
Spring Cable Connection
60mm Jaw Clip
Specification
Fastron Part Number
FRTD-Transmitter-0-400-420-24
Sensor Type
Pt100 to 4-20mA Transmitter
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
Class B
Temperature Range
0 to 400 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
Fastron Electronics FESCTHY-32-150-100mA, 150Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/2kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESCTHY-32-150-100mA
Technology
Split Core AC Current Transformer
Ratio
150/100mA
Aperture Size
32 x 32mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mA AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
150Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics FESCTHY-32-100-100mA, 100Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/2kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESCTHY-32-100-100mA
Technology
Split Core AC Current Transformer
Ratio
100/100mA
Aperture Size
32 x 32mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mA AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
100Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish SIGMA 75 CTR5+5+5+5/5.CL1.15VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5+5+5/5.CL1.15VA
Technology
AC Current Transformer
Ratio
5+5+5+5/5
VA Rating
15VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
Trent FGM6S-4P-400M 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 60kA 400 Amp, 400/690VAC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
4 Pole Disconnect
60kA Short Circuit Rating @400VAC
Suitable for Main Incoming Breaker
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Trent Part Number
FGM6S-4P-400M 400A
Functions
4 Pole MCCB
Nominal Voltage
400/690VAC @ 50/60Hz
Nominal Current Range
400 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
8kV
Operating Temperature
-25 to 50 Deg C
Mechanical Operations
20,000 Ops
Insulation Voltage
800V
Short Circuit Current (Ics)
60kA
Approvals
KEMA EUR, CE
Standards
IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
5.1kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Trent FGM6DC-2PL-320 200A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 200 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
2 Pole Disconnect
20kA Short Circuit Rating @400VAC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 200A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
200 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Trent FGM6DC-2PL-320 140A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 140 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 140A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
140 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu
20kA @ 1000VDC
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Trent FGM6DC-2PL-320 225A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 225 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 225A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
225 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Trent FGM6DC-2PL-320 80A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 80 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 80A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
80 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Fastron FRTD-PT100-50, Pt100 Air Temperature Sensor, 50mm shaft length, 77 x 77 x 55mm Body
4-20mA Output 2 Wire
Temp Measurement for 0 to 100 Deg C Max
190 x 18mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Pt100 Temp Sensing Elements
Specification
Fastron Part Number
FRTD-PT100-50
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
3
Shaft Length
190mm
Shaft Thickness
18mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Current Transducer, AT-AA9-A-1, AC Current Transducer, Average RMS, 10 Amps, 100-240VAC/DC Aux, 4-20mA output output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-A-1
Control Output
4-20mA Average RMS
Input
0-10 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet