DHR 100 C5, Hall Effect Current Sensor, 100Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 100 C5, Hall Effect Current Sensor, 100Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 100 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 100 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
ACSP-400-050, Self Powered Split Core AC Current Transducer, 400 Amp AC, 0-5V Average RMS Output, 31mm aperture
ACSP-400-050, Self Powered Split Core AC Current Transducer, 400 Amp AC, 0-5V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-5V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-400-050 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 400 Amp RMS Response Time < 200mS Output 0-5VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 200 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 100,150, 200 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DHR 400 C10, Hall Effect Current Sensor, 400Amp RMS ,10V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 400 C10, Hall Effect Current Sensor, 400Amp RMS ,10V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 400 C10 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 400 Amp Output 0-10V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
Rish Xmer Split Core 2000/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture
Heavy Item - No Free ShippingRish Xmer Split Core 2000/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 2000/5 195/80 Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 172 x 85mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
DHR 600 C5, Hall Effect Current Sensor, 600Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 600 C5, Hall Effect Current Sensor, 600Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 600 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 600 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
AHR 1000 B5, Hall Effect Current Sensor, 1000Amp, True RMS 0-5V output, 104 x 40mm aperture
Free Aus Post Shipping for $300 SpendLEM AHR 1000 B5, Hall Effect Current Sensor, 1000Amp, True RMS 0-5V output, 104 x 40mm aperture Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features Split Core VFD and SCR waveforms current measurement True RMS output 0-5V voltage output Busbar mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable or busbar up to 104 x 40mm High isolation between primary and secondary circuits Easy installation Applications -AC Power Supplies or Motors True RMS sensing - the most accurate way to monitor power supply or input power -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement. -Renewable Energy Installations or Backup Batteries Continuous condition monitoring allowing automatic failure detection and prediction -Application Domain Energy and Automation Specification LEM Part Number AHR 1000 B5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Nominal Current (RMS + DC) 1000 Amp Maximum Measurement Current (Peak) 2000 Amp Output 0-5V Isolation 5.8kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 650g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
BH-300-1-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
BH-300-1-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-300 Amp DC, Bipolar 0-10V, or Bipolar +/-10VDC Analogue Features ⌀31mm Aperture Split Core DC Bipolar or Bipolar Measurement +/-10V analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-300-1-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-300 Amp DC Response Time < 200mS Output Bipolar 0-10V, or Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
FT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm
Heavy Item - No Free ShippingFT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FT150160P Technology Split Core AC Current Transformer Ratio 1500/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 2.7kg Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
LAC 300-S/SP1, C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 30 x 13mm Aperture, +/-15V Supply, Panel Mount, X = 0.9%
Free Aus Post Shipping for $300 SpendLEM LAC 300-S/SP1, C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 30 x 13mm Aperture, +/-15V Supply, Panel Mount, X = 0.9% Features Bandwidth DC to 50kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LAC 300-S/SP1 Technology Closed Loop Hall Effect Aperture 13 x 11mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-700 Amp Output 150mA Isolation 5.5 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 0.9% Termination Style Molex series 70543-0003 Unit Weight 137g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HO 25-NP-0000 Kit 5P, Evaluation Kit 5pcs with PCB
Free Aus Post Shipping for $300 SpendLEM HO 25-NP-0000 Kit 5P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multi range through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request (see page 12) Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 25-NP-0000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-62.5 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HAC 400-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr
Free Aus Post Shipping for $300 SpendHAC 400-S O/L Hall Effect Current Sensor, 400 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAC 400-S Technology Open Loop Hall Effect Aperture 24 x 16mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Overload Capability +/- 1200 Amp Output +/-4 V Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04AG Unit Weight 70g Factory Pack Quantity 10 Datasheet Product Datasheet