Search results for "텔레@cashfilter365!~usdc전송대행돈현금화해드립니다"
-
LT 1005-S/SP4, C/L Current Transducer, Ipn = 1000A, +/-15/24VDC, 250mA Output, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LT 1005-S/SP4 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S/SP4 Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 250 mA Isolation 12 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 850g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Rish Xmer Split Core 2000/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture
Heavy Item - No Free ShippingRish Xmer Split Core 2000/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 2000/5 195/80 Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 172 x 85mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
AKR 200 C420L, AC Current Sensor, selectable 100, 150, 200 Amp, True RMS Average RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 200 C420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 100,150,200 Amp Selectable Maximum Measurement Current (Peak) 120, 180, 240 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
ACSP-100-010, Self Powered Split Core AC Current Transducer, 100 Amp AC, 0-10V Average RMS Output, 31mm aperture
ACSP-100-010, Self Powered Split Core AC Current Transducer, 100 Amp AC, 0-10V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-10V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-100-010 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 100 Amp RMS Response Time < 200mS Output 0-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 400 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 200,300,400 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
AKR 5 C420L, AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 5 C420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
ACSP-500-050, Self Powered Split Core AC Current Transducer, 500 Amp AC, 0-5V Average RMS Output, 31mm aperture
ACSP-500-050, Self Powered Split Core AC Current Transducer, 500 Amp AC, 0-5V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-5V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-500-050 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 500 Amp RMS Response Time < 200mS Output 0-5VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
HAC 800-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr
Free Aus Post Shipping for $300 SpendLEM HAC 800-S O/L Hall Effect Current Sensor, 800 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift 2500V Isolation Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 800 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAC 800-S Technology Open Loop Hall Effect Aperture 24 x 16mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 800 Amp Overload Capability +/- 1800 Amp Output +/-4 V Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04AG Unit Weight 70g Factory Pack Quantity 10 Datasheet Product Datasheet
-
AK 50 C10, AC Current Sensor, selectable 10, 20, 50 Amp, Average RMS 10V output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AK Series Average RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 10, 20, 50 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core Average RMS output 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 C10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Maximum Measurement Current (Peak) 17,34,85 Amp Output 0-10V Average RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DHR 100 C5, Hall Effect Current Sensor, 100Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 100 C5, Hall Effect Current Sensor, 100Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 100 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 100 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
ACSP-400-050, Self Powered Split Core AC Current Transducer, 400 Amp AC, 0-5V Average RMS Output, 31mm aperture
ACSP-400-050, Self Powered Split Core AC Current Transducer, 400 Amp AC, 0-5V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-5V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-400-050 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 400 Amp RMS Response Time < 200mS Output 0-5VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 200 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 100,150, 200 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition