Search results for "텔레@cashfilter365!~usdc전송대행돈현금화해드립니다"
-
HAC 600-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr
Free Aus Post Shipping for $300 SpendHAC 600-S O/L Hall Effect Current Sensor, 600 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift 2500V Isolation Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 800 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAC 600-S Technology Open Loop Hall Effect Aperture 24 x 16mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Overload Capability +/- 1800 Amp Output +/-4 V Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04AG Unit Weight 70g Factory Pack Quantity 10 Datasheet Product Datasheet
-
HAX 600-S O/L Current Transducer, 600 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output
Free Aus Post Shipping for $300 SpendLEM HAX 600-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 600-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/-1800 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HAC 300-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, Panel Mount 24 x 16mm sqr
Free Aus Post Shipping for $300 SpendHAC 300-S O/L Hall Effect Current Sensor, 300 Amp, +/-15V Supply, +/-4V Output, PanelMount 24 x 16mm sqr Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift 2500V Isolation Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 800 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAC 300-S Technology Open Loop Hall Effect Aperture 24 x 16mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Overload Capability +/- 900 Amp Output +/-4 V Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04AG Unit Weight 70g Factory Pack Quantity 10 Datasheet Product Datasheet
-
CTSC CLIP 600/5 Amp CLIP Splitcore CT 5VA, Class 1, 38mm Aperture
Free Aus Post Shipping for $300 SpendHobut CTSC CLIP 600/5 Series Current Transformer Features Low Price Point Split Core 1m Flying Leads Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Flame Retardent UL94V0 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Site Measurements Specification Hobut Part Number CTSC CLIP 600/5 Technology Split Core AC Current Transformer Ratio 600/5 Aperture Size ⌀ 40mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount Operating Temperature Range -30°C / 80°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
DHR 400 C5, Hall Effect Current Sensor, 400Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 400 C5, Hall Effect Current Sensor, 400Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 400 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 400 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
LA 55-P/SP50 C/L Hall Effect Current Sensor, 50 Amp, PCB Mount, 12.7 x 7mm Aperture, +/-12..15V Supply, X = 0.65%
Free Aus Post Shipping for $300 SpendLEM LA 55-P/SP50 C/L Hall Effect Current Sensor, 50Amp, PCB Mount with aperture, +/-12..15V Supply, X = 0.65% , Obsolete Contact Us for Possible Replacement for suggested replacement
-
DHR 500 C10, Hall Effect Current Sensor, 500Amp RMS ,10V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 500 C10, Hall Effect Current Sensor, 500Amp RMS ,10V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 500 C10 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 500 Amp Output 0-10V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
LF 306-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 25.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LF 306-S Series Closed Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 306-S Technology Closed Loop Hall Effect Aperture ø25.5mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/- 500 Amp Output 150 mA Isolation 3.8 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style Molex 5054-03/AG Unit Weight 60g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HAR 1000-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 54 x 18mm Square Aperture, +/-5V Output
Free Aus Post Shipping for $300 SpendHAR 1000-S O/L Hall Effect Current Sensor, 1000Amp, +/-15V Supply, 54 x 18mm Square aperture, +/-5V Output Specification LEM Part Number HAR 1000-S Technology Open Loop Hall Effect Aperture 18 x 54mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 50 Amp Measuring Range (Non Continuous) 2500 Amp Output +/-4 V Isolation 2.1 kV Bandwidth DC-10 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Burndy SMS6GE4 Unit Weight 400g Factory Pack Quantity 10 Datasheet Product Datasheet
-
LAC 300-S C/L Hall Effect Current Sensor, 300 Amp, 100mA Output, 30 x 13mm Aperture, +/-15V Supply, Panel Mount, X = 0.9%
Free Aus Post Shipping for $300 SpendLEM LAC 300-S Series Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LAC300-S Technology Closed Loop Hall Effect Aperture 13 x 11mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-700 Amp Output 100mA Isolation 5.5 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 0.9% Termination Style Molex series 70543-0003 Unit Weight 137g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LF 305-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 20.1mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LF 305-S Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 305-S Technology Closed Loop Hall Effect Aperture ø20.1mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 20 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/- 500 Amp Output 150 mA Isolation 3.8 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Molex 5054-03/AG Unit Weight 95g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HAT 300-S, O/L Current Transducer, 300 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output
Free Aus Post Shipping for $300 SpendLEM HAT 300-S, O/L Hall Effect Current Transducer, 300 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 300-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-900 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition