Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
AKR 200 C420L, AC Current Sensor, selectable 100, 150, 200 Amp, True RMS Average RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 200 C420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 100,150,200 Amp Selectable Maximum Measurement Current (Peak) 120, 180, 240 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
H5/100R + PMP2450WP, Proportional Controller, 42 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Panel Mount
Free Aus Post Shipping for $300 SpendH5/100R + PMP2450WP, Proportional Controller, 42 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Panel Mount Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number H5/100R + PMP2450WP Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 42 Amp (rms) Surge Capability 716 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 90-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 800g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide H5 Datasheet Equivalent Parts Contact Us for Possible Replacement
-
AHR 1000 B10, Hall Effect Current Sensor, 1000Amp, True RMS 0-10V output, 104 x 40mm aperture
Free Aus Post Shipping for $300 SpendLEM AHR 1000 B10, Hall Effect Current Sensor, 1000Amp, True RMS 0-10V output, 104 x 40mm aperture Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features Split Core VFD and SCR waveforms current measurement True RMS output 0-10V voltage output Busbar mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable or busbar up to 104 x 40mm High isolation between primary and secondary circuits Easy installation Applications -AC Power Supplies or Motors True RMS sensing - the most accurate way to monitor power supply or input power -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement. -Renewable Energy Installations or Backup Batteries Continuous condition monitoring allowing automatic failure detection and prediction -Application Domain Energy and Automation Specification LEM Part Number AHR 1000 B10 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Nominal Current (RMS + DC) 1000 Amp Maximum Measurement Current (Peak) 2000 Amp Output 0-10V Isolation 5.8kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 650g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DHR 1000 C5, Hall Effect Current Sensor, 1000Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 1000 C5, Hall Effect Current Sensor, 1000Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 1000 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 1000 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
MX110CEB, Contactor SPST-NO, 1000+ AMP, 12-48VDC, 24VDC Coil, Coil Screw M4, SPST-NO Auxiliary Contact, IP67, IP69K, Deutsch 8 Pin Connector
Free Aus Post Shipping for $300 spendGigavac MX110CEB, Contactor SPST-NO, 1000+ AMP, 12-48VDC, 24VDC Coil, Coil Screw M4, SPST-NO Auxiliary Contact, IP67, IP69K, Deutsch 8 Pin Connector Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals MIL-R-6106, ROHS MIL-STD-810G Specification Gigavac Part Number MX110CEB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 1000+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 8 Pin Deutsch Connector Aux Contact Terminals 8 Pin Deutsch Connector Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M12 Unit Weight 1600g Factory Pack Qty 1 Datasheet Product Datasheet
-
DC-0-200-420-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-200-420-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
D1D100, 3-32VDC Input, 100V, 100Amp DC Output Solid State Relay
Free Aus Post Shipping for $300 SpendCrydom D1D100, 3-32VDC Input, 100V, 100Amp DC Output Solid State Relay Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D1D100 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 100 Amp DC Surge Capability (10ms) 330 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
D4D12, Solid State Relay, DC 3-32VDC control, 12A, 400VDC Load
Free Aus Post Shipping for $300 SpendCrydom D4D12, Solid State Relay, DC 3-32VDC control, 12A, 400VDC Load Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D4D12 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 12 Amp DC Surge Capability (10ms) 36 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 500VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
RT 2000 Rogowski Coil, 2000 Amp, 125mm Aperture, 500kHz
Free Aus Post Shipping for $300 SpendLEM RT 2000 Rogowski Coil, 2000 Amp, 125mm Aperture, 500kHz Product Datasheet See ART Series for new Rogowski Coil Series
-
GX11JBB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 120VDC Coil, 61cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Free Aus Post Shipping for $300 SpendGigavac Contactor GX11JBB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 120VDC Coil, 61cm Flying Leads Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX11JJB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 120VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 61cm Flying Leads Aux Contact Terminals 61cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C, Internal Coil Supression Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
DHR 600 C5, Hall Effect Current Sensor, 600Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 600 C5, Hall Effect Current Sensor, 600Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 600 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 600 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
ITZ 5000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 5000 Amp peak, 1000mA Output, 140.5mm Aperture, 100-240VAC Supply
Heavy item - No Free ShippingHigh Precision Hall Effect Current Sensor, 5000 Amp peak, 1000mA Output, 140.5mm aperture, 100-240VAC Supply Datasheet Product Datasheet