Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
D1D100, 3-32VDC Input, 100V, 100Amp DC Output Solid State Relay
Free Aus Post Shipping for $300 SpendCrydom D1D100, 3-32VDC Input, 100V, 100Amp DC Output Solid State Relay Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D1D100 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 100 Amp DC Surge Capability (10ms) 330 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
D4D12, Solid State Relay, DC 3-32VDC control, 12A, 400VDC Load
Free Aus Post Shipping for $300 SpendCrydom D4D12, Solid State Relay, DC 3-32VDC control, 12A, 400VDC Load Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D4D12 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 12 Amp DC Surge Capability (10ms) 36 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 500VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
RT 2000 Rogowski Coil, 2000 Amp, 125mm Aperture, 500kHz
Free Aus Post Shipping for $300 SpendLEM RT 2000 Rogowski Coil, 2000 Amp, 125mm Aperture, 500kHz Product Datasheet See ART Series for new Rogowski Coil Series
-
GX11JBB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 120VDC Coil, 61cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Free Aus Post Shipping for $300 SpendGigavac Contactor GX11JBB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 120VDC Coil, 61cm Flying Leads Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX11JJB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 120VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 61cm Flying Leads Aux Contact Terminals 61cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C, Internal Coil Supression Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
IT 405-S ULTRASTAB High Precision Hall Effect Current Sensor, 400 Amp, 377mA Output, 30mm Aperture, +/-15V Supply
Heavy item - No Free ShippingIT 405-S ULTRASTAB High Precision Hall Effect Current Sensor, 400 Amp, 377mA Output, 30mm Aperture, +/-15V Supply Datasheet Product Datasheet
-
DHR 600 C5, Hall Effect Current Sensor, 600Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 600 C5, Hall Effect Current Sensor, 600Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 600 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 600 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
ITZ 5000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 5000 Amp peak, 1000mA Output, 140.5mm Aperture, 100-240VAC Supply
Heavy item - No Free ShippingHigh Precision Hall Effect Current Sensor, 5000 Amp peak, 1000mA Output, 140.5mm aperture, 100-240VAC Supply Datasheet Product Datasheet
-
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-10 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-10A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-010-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-10 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
DK 300 B10, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 0-10V unipolar output, 20-50VDC supply
LEM DK 300 B10, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 150, 225, 300 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-10V Voltage output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 300 B10 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 150,225,300 Amp Selectable Response Time < 100ms Output 0-10V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,080.00
$1,274.40 inclGST -
FT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm
Heavy Item - No Free ShippingFT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FT150160P Technology Split Core AC Current Transformer Ratio 1500/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 2.7kg Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
LT 1005-S/SP4, C/L Current Transducer, Ipn = 1000A, +/-15/24VDC, 250mA Output, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LT 1005-S/SP4 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S/SP4 Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 250 mA Isolation 12 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 850g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FTA-200-420B-24, Hall Effect DC Current Transducer, +/-200 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-200-420B-24, Hall Effect DC Current Transducer, +/-200 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-200 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-200A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-200-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-200 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST