Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
HTR 300-SB O/L Hall Effect Current Sensor, 300 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2%
Free Aus Post Shipping for $300 SpendLEM HTR 300-SB Open Loop Hall Effect Current Sensor, 300 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2% Features Bandwidth DC to 10kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range 50 to 500 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTR 300-SB Technology Split Core Open Loop Hall Effect Aperture ø21mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-600 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-10 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 2% Termination Style Molex 5046-04A/AG Unit Weight 80g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
777302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c
Free Aus Post Shipping for $300 SpendPilz 777302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 777302, E-STOP Safety Relay PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 24 - 240 VAC/DC Relay Outputs 3 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
-
DCM230 2-4-1-1 V1, DIN Rail Mount DC kWh Meter, 5-60VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
Eastron Europe DCM230 2-4-1-1 V1, DIN Rail Mount DC kWh Meter, 5-60VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved 45/60/75mV Shunt Connect RS 485 communication up to 38,400 bit/s as standard 1 x Pulse Outputs (1 Configurable) Bidirectional Measurement The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number DCM230 2-4-1-1 V1 Functions DC Energy Meter Supply Voltage 9-60VDC Nominal Measurement Range 5-60VDC Maximum Measurement Range 5-60VDC Nominal Current Input Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt Pulse Output 1 x Configurable 60/100/200ms Tariff Input N/A Accuracy Class 1 (I,U,kW,kWh) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s Weight 250g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Utility EEM Meter Setting Software Utility
$249.00
$293.82 inclGST -
Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485
Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485 Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Digital output setting 0-20mA/4-20mA/0-10V Dual output version available 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z Functions Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4-20mA/0-20mA/0-10V User Selectable Input 57 - 500VAC 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC, or 24-60VAC/DC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog
$379.00
$447.22 inclGST -
DVM 2000-B, Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 6.66V output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 2000-B, Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 6.66V output, 12kV Isolation Features Bandwidth DC to 13kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 2000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-2000V Measurement Range +/- 3000V Output 6.66V @ +/- Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw, M5 Inserts on Input Unit Weight 375g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DK 100 B5, Split Core Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 B5, Split Core Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 B5 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
GX16BEB, Contactor SPST-NO, 600+ AMP, 12-800VDC, 12VDC Coil, 8 Pin Deutsch Conector, SPST-NO Auxiliary Contact, IP67, IP69K
Free Aus Post Shipping for $300 SpendGigavac GX16BEB, Contactor SPST-NO, 600+ AMP, 12-800VDC, 12VDC Coil, 8 Pin Deutsch Conector, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX16BEB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 12VDC Load Current 600+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 8 Pin Deutsch Conector Aux Contact Terminals 8 Pin Deutsch Conector Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 900g Factory Pack Qty 1 Datasheet Product Datasheet
-
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-300 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-300 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$435.00
$513.30 inclGST -
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-20 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-20-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-20 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC
Free Aus Post Shipping for $300 SpendHOBUT M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC 0-10 Amp direct connect, or 50,75mV Shunt Backlit LCD Lockable Optional RS485 communication up to 19,200 bit/s Universal Supply 100-440VAC, or 100-420VDC Accuracy class 1 The meter is intended for measuring, and monitoring DC electrical power networks. The meter records DC power according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Optional Pulse Output Graphic LCD with illumination Specification HOBUT Part Number M850-LDD Functions DC Energy Meter Supply Voltage 100-440VAC, or 100-420VDC 0.5VA Nominal Measurement Range 15-150VDC or 30-300VDC, or 80-800VDC Maximum Measurement Range 15-800VDC Nominal Current Input 1A-10A or 50mV/75mV Shunt Infra Red Output N/A Tariff Input N/A (Optional) Accuracy Class 1 (I,U) Mounting Panle Mount Real Time Clock 1min/month (30ppm) Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 4kV RS485 Optional Weight 500g Certification CE Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+60 °C Datasheet Product Datasheet
-
MOD1 3NL 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 18kA, 40 Amp, 400/690VAC
Free Aus Post Shipping for $300 SpendIskra Doo MOD1 3NL 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 18kA, 80 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MOD1 3NL 80A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 80 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current Icu = 36kA, Ics = 18kA @ 400VAC, Ics = 20kA @ 690VAC Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet