Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
FRS 1000-SBIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 1000-SBIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coresless Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1000-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
FGS1-C/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-440-20 Nominal Voltage 440VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
FWBV414H29-300AC-010, AC Voltage Transducer, 0-300V AC input 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile
Fastron Electronics FWBV414H29-300AC-010, AC Voltage Transducer, 0-300V AC input 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 42 x 50 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number FWBV414H29-300AC-420 Control Output 4-20mA Average RMS Input 0-300VAC, 50/60Hz (25Hz - 1kHz Available on Request) Over Range x 1.2 (Continuous) Operating Temperature -25 - 70°C Load Voltage 100-240VAC/DC Termination Style Screw Mounting Style DIN Rail Mount Dimensions H:102 x W:42 x D:50mm Standards EN50022 Case Material PC - UL 94 V0 Weight 250g Factory Pack Qty 1 Datasheet Product Datasheet
$269.00
$317.42 inclGST -
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
RISH CON-CV-AVG-06-50-I-02-L, AC Voltage Transducer, 50Hz, 230VAC Full Scale, 4-20mA Output, 24-60VAC/DC Supply, LED Indicator
Free Aus Post Shipping for $300 SpendRishabh RISH CON-CV-AVG-06-50-I-02-L, AC Voltage Transducer, 50Hz, 230VAC Full Scale, 4-20mA Output, 24-60VAC/DC Supply, LED Indicator Average RMS 4-20mA output Dual output version available 250mS response time PC 94 UL V0 Each unit needs just 22.5 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number RISH CON-CV-AVG-06-50-I-02-L Measurement Output 4-20mA (Average RMS) Input 230VAC 50/60Hz Overlaod (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 24-60VAC/DC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet
-
DC-0-100-420B-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-100-420B-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-100-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-100 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
DC-0-300-420B-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-300-420B-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-300-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
H31/110M-F & FCR-400-60R-5, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-5V,500K POT Input, 400VAC, 45 Amp Per Phase @ 50 Deg C
Heavy Item - No Free ShippingFastron H31/110M-F & FCR-400-60R-5, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-5V,500K POT Input, 400VAC, 45 Amp Per Phase @ 50 Deg C 4-20mA,0-5V, or 500K POT Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Instantaneous turn-on output Direct bond copper substrate Direct power lead frame Epoxy free design Specification Trent part Number H31/110M-F & FCR-400-60R-5 Switching Type Phase Angle (Random Crossing) Control Voltage 4-20mA,0-5V,500K POT Proportional Input Load Current 40 Amp (rms) @ 50 Deg C, 45 Amp Per Phase @ 40 Deg C Surge Capability 500Amp (peak) Special Feature 3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator Mounting Style Panel Mount Load Voltage Range 180-400VAC +10% Max Non Repetitive Peak Voltage 600 Vp Termination Style Barrier Strip Screw Dimensions L:160 x W:125 x D:180mm Unit Weight 2.3kg Factory Pack Qty 20 Datasheet FCR-400-60R Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here
-
DK 400 B420, Split Core Hall Effect DC Current Transducer, Multirange 200, 300, 400A DC, 4-20mA unipolar output, 20-50VDC supply
LEM DK 400 B420, Split Core Hall Effect DC Current Transducer, Multirange 200, 300, 400A DC, 4-20mA unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 150, 225, 300 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-10V Voltage output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 400 B420 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 200,300,400 Amp Selectable Response Time < 100ms Output 4-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,207.00
$1,424.26 inclGST -
DK 200 B420 B, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 4-20mA bipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 200 B420 B, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 4-20mA bipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 100, 150, 200 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Bipolar Measurement 4-20mA analogue output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 200 B420 B Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 100,150,200 Amp Selectable Response Time < 100ms Output 4-20mA Bipolar Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
AK 50 B10, Split Core AC Current Sensor, selectable 10, 20, 50 Amp, Average RMS 10V output, 21.7mm sqr aperture
Free Aus Post Shipping for $300 SpendLEM AK 50 B10 Series Split Core AC/DC Hall Effect Sensor Compact and versatile Split Core AC current sensor, selectable 10, 20, 50Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core Average RMS output 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will nto drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Maximum Measurement Current (Peak) 17,34,85 Amp Output 0-10V Average RMS Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition