Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
FPC1-40-04C-230VAC, 4 Pole 4 x SPST NC, Modular Contactor 440VAC 40 Amp 50/60Hz, 230VAC/220VDC Coil Voltage, Hum Free
Fastron FPC1-40-04C-230VAC/DC, 4 Pole 4 x SPST NC, Modular Contactor 440VAC 40 Amp 50/60Hz, 230VAC/DC Coil Voltage, Hum Free Features 40 Amp (rms) @ 440VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FPC1-40-04C-230VAC Switching Type 4 x SPST NC Approvals CE Coil Voltage 230VAC, 50/60Hz Load Current (RMS/DC) 40 Amp (rms) @ 440VAC Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 440VAC, 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Relay Datasheet Auxiliary Contacts Selection Guide
$59.00
$69.62 inclGST -
PCM 30-P/SP2, Pointsenz Railway Bipolar DC Current Sensor, 30 Amp, Bipolar 4-20mA Output
Free Aus Post Shipping for $300 SpendLEM PCM 30-P/SP2 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 3M screened cable connection Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 30-P/SP2 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 30 Amp Measuring Range +/- 60 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style 4 Core Screened Cable 3M Unit Weight 120g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ
-
FGM6-4P-1250M 1250A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1250 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-4P-1250M 1250A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 4 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-4P-1250M 1250A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
AKR 50 B420L, Split Core AC Current Sensor, selectable 10, 20, 50 Amp, True RMS 4-20mA output, 21.7mm sqr aperture
Free Aus Post Shipping for $300 SpendLEM AKR 50 B420L Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 B420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Maximum Measurement Current (Peak) 17,34,85 Amp Output 4-20mA True RMS Aperture 21.7mm sqr Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FGS1-C/4-320-20, 320VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-320-20, 320VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-320-20 Nominal Voltage 320VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
FGM6-4P-1250M 1000A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1000 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-4P-1250M 1000A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1000 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 4 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-4P-1250M 1000A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1000 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
HAZ 6000-SBI/SP1 (OBSOLETE), O/L Hall Effect Current Transducer, 6000A, 4-20mA Bipolar Instant output, +/-15VDC supply, 42 x 162mm aperture, X = 1%
Free Aus Post Shipping for $300 SpendLEM HAZ 6000-SBI/SP1 (OBSOLETE), O/L Hall Effect Current Transducer, 6000A, 4-20mA Bipolar Instant output, +/-15VDC supply, 42 x 162mm aperture, X = 1% For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 6000-SBI/SP1 Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 6000 Amp Overload Rating 30000 At Output 4-20 mA Bipolar and Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet OBSOLETE, Contact us for possible repalcement Application Notes LEM Applications Manual 3rd Edition
-
TGLW30-4B100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW30-4B100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 4 Pole 2 Postion 64mm x 64mm Cutout Standards : IP40 Front, IP20 Terminals IEC 60947-1,-3 IEC 60204 Specification TRENT Part Number TGLW30-4B100 Functions 4 Pole AC Disconnect CAM Switch Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 100 Amp @400VAC Rated Insulation Voltage 690VAC Humidity 10-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 470g Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
RECNC46B1PA, DC Contactor SPST-NC, 400 Amp Continuous, 1000VDC, 12VDC Coil (Dual Economised), SPST-NO Auxiliary Contact, Exceeds IP69
Free Aus Post Shipping for $300 SpendRincon Power RECNC46B1PA, DC Contactor SPST-NC, 400 Amp Continuous, 1000VDC, 12VDC Coil (Dual Economised), SPST-NO Auxiliary Contact, Exceeds IP69 Features Hermetically Sealed (Patented) rated to 175 Deg C Gas Filled Normally Closed Exceeds IP69 CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed Built in dual Coil suppression for all DC Coils Flexible package for installation Specification Rincon Power Part Number RECNC46B1PA Main Contact Type SPST-NC Auxiliary Contact Type SPST-NO Coil Voltage 12VDC (Economised) Load Current 400 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 1000VDC Standards IEC60947-4-1 compliant, Meets RoHS 2011/65/EU Termination Style M12 Unit Weight 430g Factory Pack Qty 24 Datasheet Product Datasheet
-
DHR 500 C10, Hall Effect Current Sensor, 500Amp RMS ,10V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 500 C10, Hall Effect Current Sensor, 500Amp RMS ,10V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 500 C10 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 500 Amp Output 0-10V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
FGS1-C/4-385-20, 385VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-385-20, 385VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-385-20 Nominal Voltage 385VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
HAZ 14000-SRI/SP1, O/L Current Transducer, 14000 Amp, +/-15VDC supply, 4-20mA True RMS Output
Free Aus Post Shipping for $300 SpendLEM HAZ 14000-SRI/SP1, O/L Current Transducer, 14000 Amp, +/-15VDC supply, 4-20mA True RMS Output For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 14000-SRI/SP1 Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 14000 Amp Overload Rating 30000 At Output 4-20 mA True RMS Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC and 15 to 3000Hz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition