Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
PF480D25, SSR SIP, 4-15VDC Control, 25A, 48-530VAC Load
Free Aus Post Shipping for $300 SpendCrydom PF480D25, SSR SIP, 4-15VDC Control, 25A, 48-530VAC Load Features Ratings up to 25 Amp @ 660VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number PFE480D25 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-15VDC Load Current 25 Amp (rms) Surge Capability 250 Amp (peak) Special Feature None Mounting Style PCB Mount Load Voltage Range 48-480VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 25g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Accessories Din Rail Holder App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
HS211 + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps
Free Aus Post Shipping for $300 SpendHS211 + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps 4-20mA Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Specification Part Number HS211 + RS1API420MA280025R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 240 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style DIN Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A_B HS211 RS1A Series Product Notifications Pease note Changes from Gen 3 to Gen 4 (current) package design here
-
MT418 SUNAA, Programmable AC Current Transducer, Single Phase, 50/60Hz 12A AC input, 20-300VDC or 48-276VAC Aux Supply, Fully Programmable 0-10V or 4-20mA output, Standard Verison
Iskra Doo MT418 SUNAA, Programmable AC Current Transducer, Single Phase, 50/60Hz 12A AC input, 20-300VDC or 48-276VAC Aux Supply, Fully Programmable 0-10V or 4-20mA output, Standard Verison Class 0.5 (EN 60688) USB Comms as standard 0-10V or 4-20mA analogue output modules RMS values of current Simpel setting with USB self powered port Features : Measurement of nominal CT Current 0-12Amp Accuracy class 0.5 Input frequency 16 - 400 Hz RS 232/RS485 communication up to 115,200 bit/s or USBcommunication MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC User-friendly PC MiQen software Specification Iskra Doo Part Number MT418 SUNAA Functions Single Phase AC Current Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 1,5,10 Amp Maximum Measurement Range 12 Amp Alarm N/A Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (Optional RS485) Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
$336.00
$396.48 inclGST -
FGS1-C/4-275-20, 275VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-275-20, 275VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-275-20 Nominal Voltage 275VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
Rish Xmer Split Core 4000/5 Amp 195/80 Class 1, 45VA Series Current Transformer, 85 x 172mm Aperture
Heavy Item - No Free ShippingRish Xmer Split Core 4000/5 Amp 195/80 Class 1, 45VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 4000/5 195/80 Technology Split Core AC Current Transformer Ratio 4000/5 Aperture Size 172 x 85mm VA Rating 45VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
MCBC4825DL, Solid Sate Relay based Burst Fire Controller, 4-20mA Input, 480VAC 25 Amp Load, 20 Cycles
Free Aus Post Shipping for $300 SpendCrydom MCBC4825DL, Solid Sate Relay based Burst Fire Controller, 4-20mA Input, 480VAC 25 Amp Load, 20 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC4825DL Switching Type Burst Fire (20 Cycles) ROHS/CE/UL Yes Control Voltage 4 - 20mA Proportional Input Load Current 25 Amp (rms) Surge Capability 250Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 330-550VAC Overvoltage Vpk 1200V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2425W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
HS501DR + MCBC4825DL, Single Phase Proportional Burst Controller with Heatsink, 20 Cycles, 4-20mA Input, 90-530VAC, 9 Amps
Free Aus Post Shipping for $300 SpendCrydom HS501DR + MCBC4825DL, Single Phase Proportional Burst Controller with Heatsink, 20 Cycles, 4-20mA Input, 90-530VAC, 9 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 380-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + MCBC4825DL Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 9 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 380-530VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
DC-0-20-420B-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-20-420B-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-20 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-20-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-20 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
FRS 3000-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 3000-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
HS211A-DR + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps, Panel Mount
HS211A-DR + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps, Panel Mount 4-20mA Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Specification Part Number HS211A-DR + RS1API420MA280025R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 240 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style DIN Rail Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A_B HS211 RS1A Series Product Notifications Pease note Changes from Gen 3 to Gen 4 (current) package design here
$145.00
$171.10 inclGST -
Rish Xmer 62-R 100/5 Class 0.2, 1.5VA, 22mm Aperture
Free Aus Post Shipping for $300 SpendRishabh Rish Xmer 62-R 100/5 Series Class 0.2 Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 62-R 100/5 Class 0.2 Technology AC Current Transformer Ratio 100/5 Aperture Size ⌀ 22mm VA Rating 1.5VA Accuracy Class Class 0.2 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
-
PMP2425W, Phase/Burst control, 240VAC, 25 Amp, Selectable 0-5V,0-10V,4-20mA input
Free Aus Post Shipping for $300 SpendCrydom PMP2425W, Phase/Burst control, 240VAC, 25 Amp, Selectable 0-5V,0-10V,4-20mA input Features Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 170-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 286Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 170-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 160g Factory Pack Qty 20 Datasheet Product Datasheet PMP24 Installation/Wiring Guide Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent PMP2450WP RS1A Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement