H5/100R + PMP2425W, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Panel Mount
Free Aus Post Shipping for $300 SpendH5/100R + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number H5/100R + PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 296 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 90-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 800g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide H5 Datasheet Equivalent Parts Contact Us for Possible Replacement
-
DK 400 B420 B, Split Core Hall Effect DC Current Transducer, Multirange 200, 300, 400A DC, 4-20mA Bipolar output, 20-50VDC supply
LEM DK 400 B420 B, Split Core Hall Effect DC Current Transducer, Multirange 200, 300, 400A DC, 4-20mA Bipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 150, 225, 300 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-10V Voltage output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 400 B420 B Technology Bipolar DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 200,300,400 Amp Selectable Response Time < 100ms Output 4-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,297.00
$1,530.46 inclGST -
01018-886 H40A-10,000-T5-ABZC-28V/V-SC, Rotary Ultra Heavy Duty Shock Isolated Encoder, Base Mounting Feet, 10,000 Cycles per Turn(T5), Dual Output with Index, Complimentary outputs, 5-28V In/Out, w/Side Conduit
Heavy Item - No Free ShippingSensata (BEI Sensors) 10,000RPM Optical Rotary Encoder 01018-886 H40A-10,000-T5-ABZC-28V/V-SC 5-28V In/Out Centrifugal Turns per Cycle 10,000 Specification Sensata (BEI Sensors) Part Number H40A-10,000-T5-ABZC-28V/V-SC Principal Centrifugal Special Feature Heavy Duty/Shock Proof(Fully Isolated) Supply 5-28V Unit Weight 4.5kg Factory Pack Qty 1 Datasheet Product Datasheet Selection Guide Selection Guide
-
DK 20 C10 U, Hall Effect DC Current Transducer, 5, 10, 20A DC, 0-10V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 20 C10 U, Hall Effect DC Current Transducer, 5, 10, 20A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 5, 10, 20 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 20 C10 U Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 5,10,20 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DC-0-10-420B-1.0, Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-10-420B-1.0, Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-10-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-10 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
KNL18-01-415VAC AC Contactor 240/400/500/690V, Overload 144(10s), 170(5s), 200(1s), 500(0.001s) (each pole), 415VAC Control Voltage, 4 Pole 3 x NO, 1 x NC Nominal Current = 18 Amps
Free Aus Post Shipping for $300 spendIskra Doo KNL18-01-415VAC AC Contactor 240/400/500/690V, Overload 144(10s), 170(5s), 200(1s), 500(0.001s) (each pole), 415VAC Control Voltage, 4 Pole 3 x NO, 1 x NC Nominal Current = 18 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL18-01-415VAC Functions 4 Pole Contactor with Aux contacts Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 18 Amp Continuous @ 55 Deg C Overload Capability 144(10s), 170(5s), 200(1s), 500(0.001s) Auxiliary Contacts 3 x NO, 1 x NO Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 415VAC Power Dissipation 0.36W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
DK 100 C420 U, Hall Effect DC Current Transducer, 50, 75, 100A DC, 4-20mA unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 C420 U, Hall Effect DC Current Transducer, 50, 75, 100A DC, 4-20mA unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C420 U Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 4-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Thyro-ECO-A2A-400-80 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 80 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-80 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 80 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-80 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,681.91
$3,164.65 inclGST -
FRS 2500-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 2500-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485
Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485 Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Digital output setting 0-20mA/4-20mA/0-10V Dual output version available 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z Functions Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4-20mA/0-20mA/0-10V User Selectable Input 57 - 500VAC 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC, or 24-60VAC/DC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog
$379.00
$447.22 inclGST -
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-300 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-300 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$435.00
$513.30 inclGST -
DC-0-200-420-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-200-420-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00