Search results for "텔레@upcoin24*"
-
11.216.172 AME1589 MAHLE Bidirectional 24VDC Motor, 0.5kW, 2800rpm
Heavy Item - No Free ShippingISKRA LETRIKA 11.216.172 AME1589 MAHLE MAHLE Bidirectional 24VDC Motor, 0.5kW, 2800rpm Used in BROC (OIL SYSTEM) c162040000 Used in FLUITRONICS (BERENDSEN) 1239119, 1329512, 9000162924 IM0122, 11218070, AME1167, 11216172, AME1589, MM161, 11212199, AME1629 Specification ISKRA (MAHLE) Part Number 11.216.172 AME1589 ISKRA/LETRIKA 11216172 11216.172 IM0122 MAHLE 11216172 Voltage 24VDC Power 0.5kW Rotation Bidirectional Rotation Speed 2800 rpm Oil System c162040000 Tekno 1279, CH36615 Unit Weight 3.52kg Factory Pack Qty 20 Datasheet Product Datasheet
-
88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display
Free Aus Post Shipping for $300 SpendCrouzet 88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974031 (CB20-12I/8O R) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display None Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
PFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux
Free Aus Post Shipping for $300 SpendPFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux Single 1/5A CT Sensing Automatic Step Sensing (After start up sequence) Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 240VAC Aux Supply Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Rishabh Part Number PFC 08-8-R-RTC Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 240VAC (L-N), 15VA 40-70Hz +/-10% Relay Rating 250VAC/10Amp Panel Size 96 x 96mm Switch Delay Time 10s - 1800s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 10 - 1800s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 9 Smallest Capacitor Current 10mA CT Input Range 1/5 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Panel Size 96x96mm Panel Mount Comms RS485 Termination Style Screw Weight 700g Certification IEC 61326-1:2012, Table 2 (EMC), IEC 62053-21 (Accuracy), IEC 61010-1-2010 (Safety), IEC60529 (IP Rating Dust & Water) Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to IEC 61010-1-2010, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Product Datasheet User Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
-
WM3-6 230PB, kWh Sub Meter, 230/400VAC +20/-15%, Three or Single Phase, 65 Amp Direct Connect, Bidirectional Counter, Pulse Output & IR Comms, DIN Rail Mount
Free Aus Post Shipping for $300 SpendIskra Doo WM3-6 230PB Three Phase Power Meter with Pulse Output & IR Comms 65 Amp direct connect, no CT's required Ultra slim 3 DIN IR Communication as standard Pulse Output Optional RS485 communication up to 19,200 bit/s True RMS values of currents and voltages Measurements of active, reactive power Accuracy class 1 The meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of Active and Reactive Power Optional Pulse Output RS485 Comms IR Comms Graphic LCD with illumination Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number WM3-6 230PB Functions Energy Meter Supply Voltage 230V L-N, 400V L-L 5 Amp -20% +15% < 5VA Nominal Measurement Range 230V L-N, 5 Amp -20% +15% Maximum Measurement Range 230V L-N, 5 Amp -20% +15% Nominal Current Input 3 x 65 Amp AC Direct Connect Infra Red Output 19200 bit/s Tariff Input N/A (Optional) Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Dimensions 53.6 x 84 x 69.4mm (3 DIN) Pulse Output Yes Isolation 4kV RS485 (Optional) 1200-19200 b/s Weight 270g Certification UL, CSA, ROHS Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, TFT Touch Screen Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51D2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/140mm Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$1,437.00
$1,695.66 inclGST -
NP200-00, Program/Step Controller, 96x96mm, 100-240VAC, Multirange Input, 3 x DI Inputs, Universal Relay/SSR/4-20mA Outputs, 10 Alarms
NP200-00, Program/Step Controller, 96x96mm, 100-240VAC, Multirange Input, 3 x DI Inputs, Universal Relay/SSR/4-20mA Outputs, 10 Alarms Multirange Output and Input, User Selectable 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number NP200-00 Control Output 1 (Heat) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4), or 4-20mA, or SSR (12VDC, 30mA 600 Ohm) Control Output 2 (Cool) N/A Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 SV2, SV3 Setpoints Mounting Style 96 x 96mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 450g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet NP200 Series Datasheet NP200 Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$598.00
$705.64 inclGST -
FTA-100-010-24, Hall Effect DC Current Transducer, +/-100 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-100-010-24, Hall Effect DC Current Transducer, +/-100 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-100 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-100A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-100-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-100 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-400-420B-24, Hall Effect DC Current Transducer, +/-400 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-400-420B-24, Hall Effect DC Current Transducer, +/-400 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-400 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-400A ~+/-400A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-400 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-15 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
Sentinel 3+ Battery Impedance, Voltage and Temperature Sensor Gen 3+, Accuracy 0.5%, S-Bus Output
Free Aus Post Shipping for $300 SpendSentinel 3+ Battery Sensor Gen 3+, DIN Rail Mount Compact and versatile 3 in 1 Battery sensor for monitoring of critical battery systems, included Flooded Cell, and VLRA types. The Sentinel 3+ is a state of the art, System on Chip (SoC) digital transducer designed to monitor VRLA, gel or flooded stationary battery systems. Data is transmitted over a dedicated communication bus to proprietary and non-proprietary devices Features Din Rail Mount, Compact Design LED status indicator Temperature patch for direct battery measurement Communication interface isolation 2.16 kV Fast, simple fittings , Voltage, Temperature and True AC Impedance Measurement S-Bus Output (Interface with OEM equipment) Suitable for Transformerless UPS systems (may require Common mode Isolator) Isolated plastic case recognised according to UL94-V0 Advantages Excellent sensitivity, accuracy, and repeatability High current stimulation for secure impedance measurement Improved immunity to Common Mode transients in newer UPS topologies (ie. transformerless, using fast IGBTs and/or a floating battery with respect to earth ground). Applications UPS Telecommunications Battery supplied applications Application Domains Energy & Automation Industrial. Utilities Fire & Safety system Remote monitoring LEM Part Number BM Sentinel 3+ Technology SoC 3 in 1 sensor CE Approved Yes Supply Voltage 0.9 .. 16VDC @ 30mA Voltage Measurement Range 0.9 .. 16VDC @ 30mA Temperature Measurement Range -10°C / 70°C Output S-Bus Digital protocol Isolation 2.16kV (AC, 50Hz, 1 min) S-Bus Baud Rate 9600 bps Mounting Style Din Rail Mount Operating Temperature Range -10°C / 70°C Accuracy 0.5% Termination Style 6 Pin Connector (for BM CBL POW 0.4/0.6M) Unit Weight 70g Factory Pack Qty 6 Datasheet Used to monitor and measure battery Impedance, Voltage, and Surface Temperature. Product Datasheet S-Bus Protocol Information OEM Software Tools Sentinel 3 Commander Test Program Sentinel Troubleshooting Harsh EMC Application Notes In a UPS, the current drawn by the inverter contains line frequency harmonic components (mostly 2nd, 4th and 6th). Part of this ripple current flows through the battery, to which is connected the Sentinel. As the Sentinel itself uses an excitation current for the impedance measurement, so the presence of ripple current can interfere with the measurement and thus cause errors. The table below quantifies the additional error resulting from 1A rms of ripple current, for different combinations of ripple current harmonics and bloc voltage. Table 1: Additional errors for impedance measurement due to ripple current (See datasheet) Notes: The error values are the maximum, and are normalized for 1A rms of ripple current. The error is proportional to the ripple current; for example, if the ripple current was 2A rms the error will increase by factor 2.
-
E500M-1032, BACnet Communication Module for Secure, Elite 500 Series
Elite E500M-1032, BACnet Communication Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$445.00
$525.10 inclGST -
H-15-2-24, Split Core Hall Effect DC Current Transducer, 0-15 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-15-2-24, Split Core Hall Effect DC Current Transducer, 0-15 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture Split Core DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-15-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-15 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet