DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-TR Transmitter Output 4-20mA Input Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
ACD15AR/M Servo Motor Controller, 96x96mm, 100-240VAC
Free Aus Post Shipping for $300 SpendShinko ACD15AR/M Series Digital Indicating Servo Controllers • Program control, converter function are standard features • 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) • Drip-proof / Dust-proof IP66 (front panel only) • 9-step pattern (for SV and time) is a standard feature • UL/CSA Approved • Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) • Each unit needs just 60 mm depth panel space • EC Compliant (Details) Specification Shinko Part Number ACD15AR/M Control Output 4 - 20mA Input Multirange (refer to datasheet) Alarm 2 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 None Mounting Style 96 x 96mm Panel Mount Supply Voltage 100 - 240VAC Termination Style Screw Weight 330g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet ACD Series Brochure ACD Series Instruction Manual ACD Series RS485 Comms Instruction Manual Delivery 3-4 weeks delivery if not in stock
-
MCBC2450CF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 10 Cycles
Free Aus Post Shipping for $300 SpendCrydom MCBC2450CF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 10 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC2450CF Switching Type Burst Fire (10 Cycles) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 180-280VAC Overvoltage Vpk 600V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2425W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 125 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 125V Measurement Range +/- 187.5V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LTC 600-T C/L Hall Effect Current Sensor, 600 Amp, 100mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.7%
Free Aus Post Shipping for $300 SpendLEM LTC 600-T Closed Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm
Heavy Item - No free ShippingISKRA LETRIKA (MAHLE) 11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm MAHLE Part # MM 191 11212.958 11212958 IM0055 Specification ISKRA (MAHLE) Part Number 11.212.935 AMJ5265 MAHLE ISKRA/LETRIKA/MAHLE IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 Voltage 12VDC Power 1.6kW Rotation Unidirectional Clockwise Rotation Speed 2600 rpm Unit Weight 6.9kg Factory Pack Qty 1 Cross Reference FLUITRONICS (BERENDSEN) 1240247, 9000566912 LUCAS 47044608 MAHLE LETRIKA (ISKRA) IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 SPX FLUID POWER (FENNER) MF4034 MAKE MODEL TYPE ENGINE POWER YEARS BUCHER HYDRAULICS (HIDROIRMA) PEDRO ROQET SPX FLUID POWER (FENNER) WEBER Spare Parts Spare Parts Page
-
Thyro-A-1A-500-100-H-RLP3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Advanced Energy Thyro-A-1A-500-100-H-RLP3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes Features Optional Profinet,Profibus,Ethernet,Modbus Comms 500VAC +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-500-100-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,882.00
$3,400.76 inclGST -
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-20 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-20-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-20 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-25 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-25-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-25 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 25Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-5 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-5A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-5 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-200-420-24, Hall Effect DC Current Transducer, 0-200 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-200-420-24, Hall Effect DC Current Transducer, 0-200 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-200 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-200A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-200-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-200 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-200-010-24, Hall Effect DC Current Transducer, +/-200 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-200-010-24, Hall Effect DC Current Transducer, +/-200 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-200 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-200A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-200-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-200 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST