Search results for "텔레@upcoin24*"
-
DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation, SP3 has extra long thread terminals Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 4200/SP3 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4200V Measurement Range +/- 6000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,642.00
$1,937.56 inclGST -
11.212.737 AMJ5197 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm
Heavy Item - No Free ShippingISKRA LETRIKA (MAHLE) 11.212.737 AMJ5197 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm MAHLE Part # MM 327 ISKRA(Letrika) 11212737 IM0039 Specification ISKRA (MAHLE) Part Number 11.212737 AMJ5197 ISKRA/LETRIKA/MAHLE 11212737 IM0039 MM 327 Voltage 12VDC Power 1.6kW Rotation Unidirectional Clockwise Rotation Speed 2750 rpm Oil System BROC c1620S1020 Notes Hydraulics, Insulated ground, Termo protection Unit Weight 7.6kg Factory Pack Qty 1 Cross Reference A.V.I. 610801200070 ANTEO 358001 HYDROVEN 56250A160L2K MAHLE LETRIKA (ISKRA) IM0039, 11218093, AMJ5197, 11212737, AMJ5197, MM327 SMOES CC12V1600WCONT WESTERN MOTORS AMJ5197 Spare Parts Spares Page
-
H-30-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-30 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-30-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-30 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-30 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-30-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-30 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
H-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-400 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-400-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-400 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
MC740 S SFUNC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500VAC L-L 50/60Hz Measurement, 240VAC Supply, USB Comms, w/ Supercap
Free Aus Post Shipping for $300 SpendIskra Doo MC740 S SFUNC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500VAC L-L 50/60Hz Measurement, 240VAC Supply, USB Comms, w/ Supercap Smart Meter Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Usage The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods 32 adjustable alarms Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Specification Iskra Doo Part Number MC740 S SFUNC Functions Power Quality Meter, Energy Meter, Power Transducer, Network Analyser Supply Voltage 240VAC < 5VA 50/60Hz Nominal Measurement Range 50-500VAC L-L, 5 Amp Maximum Measurement Range 750V L-N, 12.5 Amp Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 2GB Isolation 3.7kV Ethernet RJ45 10/100Mbit/s USB Yes (2400-115200 b/s) RS232/RS485 N/A (optional 2400-115200 b/s) Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 6400 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 6400V Measurement Range +/- 9500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$2,806.00
$3,311.08 inclGST -
N2154JK060, Thyristor(SCR) PUK 1562 Amp, 600V, 41/14
N2154JK060, Thyristor(SCR) PUK 1562 Amp, 600V, 41/14 Capsule Features Very low forward voltage drop Very low leakage current International standard package 41/14 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Controlled Rectifiers AC Switch Battery Chargers Phase Controllers Water Cooled AC switches Power Factor Correction Specification Wescode Part Number N2154JK060 Vrrm 600V SCR Configuration Thyristor(SCR) Capsule PUK IF(av) @ 85 Deg C 1562 Amp Package Size ø41 x 14mm Itsm 22.7 kA VF(to) .89V Tj(max) 125°C rF 0.107mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-k) (double sided cooled 180°sin) 0.027°C/W R th(c-h) (double sided cooled) NA Weight 135g Clamping Force 10-20kN Factory Pack Qty 12 Certification ROHS IXYS-Westcode Headquarters USA Datasheet Product Datasheet Alternatives Replaces T1080N06T Contact Us for other Possible Replacements Heatsink Heatsink Profiles
$345.00
$407.10 inclGST -
LTC 350-T C/L Hall Effect Current Sensor, 350 Amp, 175mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.3%
Free Aus Post Shipping for $300 SpendLEM LTC 350-T Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1200 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 With Busbar Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 350-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 350 Amp Measurement Range +/- 1200 Amp Output 175 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° Nickel Plated Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Fixing kit see Part # 93.34.43.100.0
-
H5/100R + PMP2425W, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Panel Mount
Free Aus Post Shipping for $300 SpendH5/100R + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number H5/100R + PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 296 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 90-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 800g Factory Pack Qty 20 Datasheet Product Datasheet PMP24 Installation/Wiring Guide H5 Datasheet Equivalent Parts Contact Us for Possible Replacement
-
DTC1-A/M1-2O, DIN Rail Mount Transmitter, Multirange Thermocouple Input, 24VAC/DC, 2 x 4-20mA Outputs
Free Aus Post Shipping for $300 spendFastron DTC1-A/M1-2O, DIN Rail Mount Transmitter, Multirange Thermocouple Input, 24VAC/DC, 2 x 4-20mA Outputs Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M1-2O Control Output 2 x 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Output Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
84870200, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply 8 Amp changeover/SPDT, 2 Level Control, Fixed Timing function, ENR 24-240VUC
Crouzet 84870200, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply 8 Amp changeover/SPDT, 2 Level Control, Fixed Timing function, ENR 24-240VUC Level Switch, 110/240VAC or 24VAC/DC Aux Supply 1 x 16 Amp changeover/SPDT (AgNi / Silver Alloy) Relay Features : 1. one-level switch of conductive liquids 2. two-level switch of conductive liquids ! One-state device monitors one level, two-state device monitors two levels (switches on one level and switches off on another level) Choice of function PUMP UP, PUMP DOWN Sensitivity adjustable by a potentiometer (5-100 kÙ) Measuring frequency 10Hz prevents polarization of liquid and raising oxidation of measuring probes Galvanically separated supply voltage UNI 24.. 240 VAC/DC Output contact 1xchangeover/SPDT 8A/250V AC1 1-module type, mounting onto a DIN rail Specification Crouzet Part Number 84870200 Voltage Range 110/240VAC or 24VAC/DC Sensitivity (Input resistance) 250Ohm to 1MOhm Electrode Voltage 3.5 max Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Peak Overload (10s) 100 Amp Time delay T1 max. 400 ms Time delay T2 adjustable 0.1-10 s Control Type 2 Level Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 1 x 16 A / AC1 Breaking capacity 2500 VA / AC1, 250 W / DC Inrush current (3s) 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet Sensors for use with PLT Series Tank Level Sensors
$159.00
$187.62 inclGST -
Modbus RTU Anybus Module, Comms Interface for Thyro PX or Basic Bus Module
Advanced Energy Modbus RTU Anybus Module, Comms Interface for Thyro PX or Basic Bus Module Optional Connection for up to 8 Power Controllers with 8 Modules For Thyro PX or Basic Bus Communication Options : Ethernet/IP Profibus DPV1 Modbus RTU Modbus TCP DeviceNet ProfiNET EtherCAT Specification Advanced Energy Part Numbers EthernetIP(2.000.090.015)ProfiNET(2.000.190.011)ModbusTCP(2.000.190.013)ProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)EtherCAT(2.000.190.016) Functions (Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parametersTransfer of setpoints as float number in physical unitsControl Function of LED's Protocols EthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU Weight 250g Factory Pack Qty 1 Approvals CE, UL Operating Temperature -20 ???? ??C ?? Datasheet and Guides Product Datasheet Setting Up Comms on Thyro A Series Controllers Thyro Touch Software and Touch Display User Guide Anybus Device Ethernet IP Setup Guide
$577.50
$681.45 inclGST