FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-45 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
SDM630MCT-MODBUS-MID-CL1 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms
Free Aus Post Shipping for $300 SpendEastron Europe SDM630MCT-MODBUS-MID-CL1 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 0.333V CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms 1/5 Amp CT Input RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-MODBUS-MID-CL1 V2 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility
-
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-15 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-015-420-24, DC Current Transducer, 0-15 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-015-420-24, DC Current Transducer, 0-15 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-20 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-20mA ~0-20A AC) 10uS Response (0-0-20A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-15 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-050-420-24, Hall Effect DC Current Transducer, 0-50 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-050-420-24, Hall Effect DC Current Transducer, 0-50 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-50 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-50A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-50 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-850 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-850-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-850 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
BH-200-2-24, Split Core Hall Effect DC Current Transducer, +/-200 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-200-2-24, Split Core Hall Effect DC Current Transducer, +/-200 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-200 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-200-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-200 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$435.00
$513.30 inclGST -
FTA-400-420B-24, Hall Effect DC Current Transducer, +/-400 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-400-420B-24, Hall Effect DC Current Transducer, +/-400 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-400 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-400A ~+/-400A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-400 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
KNL75-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, with 1 x NO 1 x NC, Nominal Current = 75 Amps, 24VAC Coil
Free Aus Post Shipping for $300 SpendIskra Doo KNL75-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, with 1 x NO 1 x NC, Nominal Current = 75 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL75-11-24VAC Functions 3 Pole Contactor (3 x NO, with 1 x NO, 1 x NC Aux Contacts) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 75 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO, with 1 x NO, 1 x NC Aux Contacts (6 Amp) Optional NDL4-40, 4 Pole Snap On Aux Contacts Trip Delay Time 2-10ms Electrical Life 500,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 6W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 950g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
ART-B22-D70-SP6 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter, SP6 = 6M Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D70-SP6 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter, SP6 = 6M Cable The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Included Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D70-SP6 + AI-PMUL - 3Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Applicaton Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.