Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
SKiiP 24AC12T4V1, IGBT Trench 4, H Bridge, 50Amp, 1200V
Semikron SKiiP 24AC12T4V1, IGBT Trench 4, H Bridge, 50Amp, 1200V Features IGBT & Diode Rectifier with Chopper/Brake Pressure Contact Technology Electrically insulated base plate Press Mounted Style 2500V Isolation 61mm Base Width Applications Frequency Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Inverter Drives Specification Semikron Part Number SKiiP 24AC12T4V1 Vces 1200V Transistor Configuration H Bridge IGBT Module Ic(nom) @ 80 Deg C 90 Amp Package Size W:81.5mm L:58.5mm D:16mm Terminals M6 Screw Mounting 2 x M12 Weight 100g Mounting Torque 5 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Semikron Headquarters Germany Datasheet Product Datasheet Alternatives No Alternative
$174.00
$205.32 inclGST -
VX4-UMCA-A2, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, Relay Output, 4-20mA Cooling Output, 2 Alarms
VX4-UMCA-A2, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, Relay Output, 4-20mA Cooling Output, 2 Alarms Multirange Input (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number VX4-UMCA-A2 Control Output 1 (Heat) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Control Output 2 (Cool) N/A Input Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals. Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2nd Alarm 2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 4-20mA Cooling Output Mounting Style 48 x 48mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet VX Series Brochure VX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$275.00
$324.50 inclGST -
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-50A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC
Free Aus Post Shipping for $300 SpendGIC Controls MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC Relay control, on 3-phase networks : Overvoltage between phases, Undervoltage between phases Overvoltage between phases and neutral, Undervoltage between phases and neutral, Loss of neutral Multi-voltage Products Controls its own supply voltage True RMS measurement LED status indication 3-phase voltage controllers which monitor : Undervoltage, adjustable from -20 to -2 % of Un Overvoltage, adjustable from 2 to 20 % of Un Measurements are taken between neautral and Phases for MG73BQ MG73BQ and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation. Specification GIC Controls Part Number MG73BQ (3 Phase 4 Wire/Single Phase Monitoring Relay With DPDT Contacts) Function Undervoltage/Overvoltage between phases Nominal Voltage 3 x 120 → 3 x 240 V ∿ Digital Outputs 2 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Timing Range 0.3 → 30s (0, +10%) Delay on Pickup 500ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Fixed Hysteresis 2% of Un Maximum Measurement Cycle Time 150ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range Same as Measurement 3 x 220 → 3 x 480 V ∿ Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
DVL 150 UI, Digital Voltage Transducer 150V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 150 UI, Digital Voltage Transducer 150V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 150 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 150V Measurement Range +/- 225V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST -
KD6 40100M2, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC, 4 x Programmable Analogue Inputs, Modbus TCP/RTU,HTTP/NTP/FTP/RS485/USB Comms, csv File Datalogging
Free Aus Post Shipping for $300 SpendLumel KD6 40100M2, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC, 4 x Programmable Analogue Inputs, Modbus TCP/RTU,HTTP/NTP/FTP/RS485/USB Comms, csv File Datalogging Independent logging System Internal Web page 8GB Flash Memory USB/RS485/Ethernet Comms as standard Modbus TCP/RTU,HTTP/NTP/FTP Protocols Universal 85-253VAC, 90-300VDC Supply Optional 6 x Relay outputs Optional Binary Inputs and Outputs Optional Additional 4 Analogue Inputs Specification Lumel Part Number KD6 40100M2 Functions Communication Data logger and Internal Web page Supply Voltage 90-300VDC or 85-253VAC Protocols TCP/RTU/HTTP/NTP/FTP Communication Ports RS485/USB,Ethernet RS485/RS232 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200 bit/s USB Baud Rate 115200 bit/s Ethernet Baud Rate 10,100 Mbit/s Real Time Clock 1min/month (30ppm) Isolation 3.5kV Weight 600g Factory Pack Qty 1 EU Directives EN61000, EN61010 Safety Protection Class II Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
88974162, Millenium 3 Essential XD26-16I/10O S, 16 x On/Off inputs, Incl 6 analogue inputs, 10 x Static Solid State outputs incl 4 x PWM output, 24 VDC
Free Aus Post Shipping for $300 SpendCrouzet 88974162 Millenium 3 Series Programmable Logic Controllers Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974162 (XD26-16I/10O S) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs SSR, 12-24VDC @ 500mA (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display Yes Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
H-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 4kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 2000/5 Class 0.5 20VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 85 x 125mm Burden 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
-
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms 1/5 Amp CT Input LoRaWaN AU915 Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-LORAWAN-MID-AU915 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV Comms LoRaWaN AS915 Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Modbus Utility EEM Meter Setting Software Utility
$339.00
$400.02 inclGST -
DTC1-A/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Thermocouple Input, 24VAC/DC, 4-20mA output
Free Aus Post Shipping for $300 spendFastron DTC1-A/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Thermocouple Input, 24VAC/DC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M1-C5 Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual