ND4C-22, 6 Amp Snap on Auxiliary Contacts for K03, K07 and K08 Series Miniature Contactors, 2 x NO, 2 x NC Aux Contacts
Free Aus Post Shipping for $300 SpendND4C-22, 6 Amp Snap on Auxiliary Contacts for K03, K07 and K08 Series Miniature Contactors, 2 x NO, 2 x NC Aux Contacts Features Snap on 2 x NO, 2 x NC 6 Amp Contacts 20 grams
-
Thyro-A-2A-400-170-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only
Advanced Energy Thyro-A-2A-400-170-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-170-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,003.00
$3,543.54 inclGST -
FGS1-C/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-440-20 Nominal Voltage 440VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
RS1API420MA280080R, Solid State Relay Based Integrated Proportional Controller, 4-20mA Input, 240VAC 80Amp Load
Free Aus Post Shipping for $300 SpendRelequick RS1API420MA280080R Proportional Phase Control Solid State Relays 4-20mA, or 2-10V Proportional Phase Control Input Ratings from 25A to 100 Amp @ 70-280 VAC SCR output for heavy industrial loads Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Relequick Part Number RS1API420MA280080R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4 - 20mA Load Current 80 Amp (rms) Surge Capability 910 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 70-280VAC Max Non Repetitive Peak Voltage 850 Vp Termination Style Screw Unit Weight 160g Factory Pack Qty 20 Datasheet Product Datasheet Product Notifications Equivalent Parts Crydom MCPC2450 MCPC2490 or Contact Us for Possible Replacement
-
84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC
Crouzet 84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC Level Switch, 110/240VAC or 24VAC/DC Aux Supply 2 x 5 Amp changeover/SPDT (AgNi / Silver Alloy) Relay Features : 1. one-level switch of conductive liquids 2. two-level switch of conductive liquids ! One-state device monitors one level, two-state device monitors two levels (switches on one level and switches off on another level) Choice of function PUMP UP, PUMP DOWN Adjustable time delay on the output (0.5 - 10 s) Sensitivity adjustable by a potentiometer (5-100 kÙ) Measuring frequency 10Hz prevents polarization of liquid and raising oxidation of measuring probes Galvanically separated supply voltage UNI 24.. 240 VAC/DC Output contact 1xchangeover/SPDT 8A/250V AC1 1-module type, mounting onto a DIN rail Specification Crouzet Part Number 84870210 Voltage Range 110/240VAC or 24VAC/DC Sensitivity (Input resistance) 50kOhm to 1MOhm Electrode Voltage 3.5 max Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Peak Overload (10s) 100 Amp Time delay T1 max. 400 ms Time delay T2 adjustable 0.1-10 s Control Type 1 or 2 Level Number of contacts 2 x changeover/ SPDT (AgNi / Silver Alloy) Rating 2 x 5 A / AC1 Breaking capacity 2500 VA / AC1, 250 W / DC Inrush current (3s) 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet Sensors for use with PLT Series Tank Level Sensors
$189.00
$223.02 inclGST -
FRS3-C40-750R, 750VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS3-C40-750R, 750VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS3-C40-750R Nominal Voltage 750VDC No of Poles 3 Category IEC / EN / VDE Type 1 (Class I) + Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$109.00
$128.62 inclGST -
KNL250-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 250 Amps, 24VAC Coil
Heavy Item - No free ShippingIskra Doo KNL250-00-24VAC Contactor Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL250-00-24VAC Functions 3 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 250 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO Trip Delay Time 2-10ms Electrical Life 1,100,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 24.5W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 9.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
DRH3P60A18, 18 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO)
Free Aus Post Shipping for $300 spendCrydom DRH3P60A18, 18 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO) Features 20 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRH3P60A18 Switching Type Zero Crossing Approvals ROHS,CE,ULIEC Control Voltage 90-280VAC Transient Voltage 1200V Load Current (per phase) 18 Amp (rms) Surge Capability (10ms) 650 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FIR-16-2C-24VAC/12VDC, 2 Pole 2 x SPDT CO, Bistable Relay with Manual Override 440VAC 16 Amp 50/60Hz, 24VAC/12VDC Control Voltage
Fastron FIR-16-M-24VAC/12VDC, 2 Pole 2 x SPDT CO, Bistable Relay 440VAC 16 Amp 50/60Hz, 24VAC/12VDC Control Voltage Features 16 Amp (rms) @ 440VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FIR-16-M-24VAC/12VDC Switching Type 2 x SPDT CO Approvals CE Coil Voltage 24VAC/12VDC Load Current (RMS/DC) 16 Amp (rms) @ 416VAC Special Feature Mounting Style DIN Rail Mount Load Voltage Range 440VAC 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Relay Datasheet
$33.60
$39.65 inclGST -
FBS RK SD 110, 110VDC 2 Pole Surge Protection Device for Balanced IT Systems, 5kA, LPZ 0 -2 or higher
FBS RK SD 110, 110VDC 2 Pole Surge Protection Device for Balanced IT Systems, 5kA, LPZ 0 -2 or higher Application Balanced IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK SD 110 Nominal Voltage 110VDC No of Poles 2 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use Balanced IT Communications Line/signals Protection modes L1+/L2+/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$29.00
$34.22 inclGST -
FRS2-C40-1000R, 2 Pole, 1000VDC Surge Protection Device for DC/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS2-C40-1000R, 2 Pole, 1000VDC Surge Protection Device for DC/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS2-C40-1000R Nominal Voltage (Un) 1000VDC Maximum PV Operating Voltage (Ucpv) 1200VDC Voltage Protection Level (Up) <4kV No of Poles 2 Category IEC / EN / VDE Type 2 (CLass II) Location of use Battery/Solar System/UPS Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 400g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$79.00
$93.22 inclGST -
FGM6DC-2PL-800 800A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 800 Amp, 1500VDC
Heavy Item - No Free ShippingTrent FGM6DC-2PL-800 800A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 800 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 20kA Short Circuit Rating @1000VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-2PL-800 800A Functions 2 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 800 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -25 to 70 Deg C Electrical Operations 20,000 Ops Insulation Voltage 1500V Short Circuit Current (Ics/Icu) 20kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed) Weight 9.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet CE Declaration