Search results for "텔레@coinsp24^^소액결제세탁trc20사는법"
-
SQ0214 L 110V 10 SNSA Synchroscope (Synchronoscope)
Free Aus Post Shipping for $300 SpendIskra Doo 110VAC SQ0214 L 110V RC S2SA Synchroscope (Synchronoscope) Measurement of phase difference between bus bar and generator Five instruments in one (SQ 0x14) Circular display of ∆ phase difference Magnifield display of phase difference ∆ = ±20 Microprocessor processing Simple synchronization conditions setting Output relay for synchronisation (pulse or continuous) ''Dead busbar or generator'' functionality Power supply from bus bar or generator Standard 96x96 mm or 144x144 mm din housing LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only) High immunity to EMC disturbances Special functions set with three jumpers inside the instruments Status output Green led for indication of both voltages Ship version (Bureau veritas certificate - SQ 02x4) Specification Iskra Doo Part Number SQ0214 L 110V 10 SNSA Function Phase Difference (∆ϕ) Measurement Nominal Voltage (Un) 100VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz Digital Output Relay 250 V, 1 A, 50 Hz, 250 VA Status Output Open-Collector 24 Vdc + 20% @30mA Switch On Delay Time Range 0,1 ... 1 s +/-10% Phase Difference Setting Range -2 ... 20 °el ± 3 °el Voltage Difference Setting Range 1 ... 10 % +/-2.5% Dead Busbar Noise Rejection Range 10%, 20%, 30% or 40% Power Consumption < 4VA Short Term Overload 2 x Un for 3 seconds LCD Display Accuracy Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el Synchronisation Accuracy +/- 10% Termination Style Screw Weight 530g Certification CE Factory Pack Qty 1 Enclosure Version Standard Version Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP52 for case, IP20 for terminals with protective cover Safety According to EN 61 010-1 400 V, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet User Manual Application Notes & Software Downloads The following parameters can be set via internal jumper see User Manual for more details. Dead Busbar Generator Function Over and Under Frequency Synchronising Adjustable Lenght of a Sync Pulse The following parameters Can be set via MIPack Comms Module & SQset Setting Software Relay - 300mS/Continuous/Programmable Dead Busbar - Active DB/Active DB + DG & % Threshold MIPack User Manual Download SQSet Settign Software
-
FGS1-C/3-320-20, 320VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/3-320-20, 320VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/3-320-20 Nominal Voltage 320VAC No of Poles 3 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$90.00
$106.20 inclGST -
Thyro-A-2A-400-30-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options
Advanced Energy Thyro-A-2A-400-30-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-30-HRLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,680.70
$3,163.23 inclGST -
FIR-16-2C-24VDC, 2 Pole 2 x SPDT CO, Bistable Relay with Manual Override 440VAC 16 Amp 50/60Hz, 24VDC / 48VAC Coil Voltage
Fastron FIR-16-M-24VDC / 48VAC, 2 Pole 2 x SPDT CO, Bistable Relay 440VAC 16 Amp 50/60Hz, 24VDC / 48VAC Control Voltage Features 16 Amp (rms) @ 440VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FIR-16-M-24VDC / 48VAC Switching Type 2 x SPDT CO Approvals CE Coil Voltage 24VDC / 48VAC Load Current (RMS/DC) 16 Amp (rms) @ 416VAC Special Feature Mounting Style DIN Rail Mount Load Voltage Range 440VAC 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Relay Datasheet
$33.60
$39.65 inclGST -
Thyro-A-2A-400-280-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only
Advanced Energy Thyro-A-2A-400-280-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-280-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$4,156.90
$4,905.14 inclGST -
Rish Con M+ CM44111211, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display
Rishabh Rish Con M+ CM44111211, , Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V (Programmable) Free Program Software 300mS response time PC 94 UL V0 Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con M+ CM44111211 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 2 x 4-20mA/0-20mA/0-10V User Selectable and Programable Relay Output 2 Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 100 - 600VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-285VAC/DC Accuracy 0.2% Current, Voltage (0.5% Power) Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog Brand Comparison to Iskra UMT540 or MT540 Series
$629.00
$742.22 inclGST -
ND4C-22, 6 Amp Snap on Auxiliary Contacts for K03, K07 and K08 Series Miniature Contactors, 2 x NO, 2 x NC Aux Contacts
Free Aus Post Shipping for $300 SpendND4C-22, 6 Amp Snap on Auxiliary Contacts for K03, K07 and K08 Series Miniature Contactors, 2 x NO, 2 x NC Aux Contacts Features Snap on 2 x NO, 2 x NC 6 Amp Contacts 20 grams
-
Thyro-A-2A-400-170-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only
Advanced Energy Thyro-A-2A-400-170-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-170-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,003.00
$3,543.54 inclGST -
FGS1-C/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-440-20 Nominal Voltage 440VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
RS1API420MA280080R, Solid State Relay Based Integrated Proportional Controller, 4-20mA Input, 240VAC 80Amp Load
Free Aus Post Shipping for $300 SpendRelequick RS1API420MA280080R Proportional Phase Control Solid State Relays 4-20mA, or 2-10V Proportional Phase Control Input Ratings from 25A to 100 Amp @ 70-280 VAC SCR output for heavy industrial loads Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Relequick Part Number RS1API420MA280080R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4 - 20mA Load Current 80 Amp (rms) Surge Capability 910 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 70-280VAC Max Non Repetitive Peak Voltage 850 Vp Termination Style Screw Unit Weight 160g Factory Pack Qty 20 Datasheet Product Datasheet Product Notifications Equivalent Parts Crydom MCPC2450 MCPC2490 or Contact Us for Possible Replacement
-
84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC
Crouzet 84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC Level Switch, 110/240VAC or 24VAC/DC Aux Supply 2 x 5 Amp changeover/SPDT (AgNi / Silver Alloy) Relay Features : 1. one-level switch of conductive liquids 2. two-level switch of conductive liquids ! One-state device monitors one level, two-state device monitors two levels (switches on one level and switches off on another level) Choice of function PUMP UP, PUMP DOWN Adjustable time delay on the output (0.5 - 10 s) Sensitivity adjustable by a potentiometer (5-100 kÙ) Measuring frequency 10Hz prevents polarization of liquid and raising oxidation of measuring probes Galvanically separated supply voltage UNI 24.. 240 VAC/DC Output contact 1xchangeover/SPDT 8A/250V AC1 1-module type, mounting onto a DIN rail Specification Crouzet Part Number 84870210 Voltage Range 110/240VAC or 24VAC/DC Sensitivity (Input resistance) 50kOhm to 1MOhm Electrode Voltage 3.5 max Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Peak Overload (10s) 100 Amp Time delay T1 max. 400 ms Time delay T2 adjustable 0.1-10 s Control Type 1 or 2 Level Number of contacts 2 x changeover/ SPDT (AgNi / Silver Alloy) Rating 2 x 5 A / AC1 Breaking capacity 2500 VA / AC1, 250 W / DC Inrush current (3s) 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet Sensors for use with PLT Series Tank Level Sensors
$189.00
$223.02 inclGST -
FRS3-C40-750R, 750VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS3-C40-750R, 750VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS3-C40-750R Nominal Voltage 750VDC No of Poles 3 Category IEC / EN / VDE Type 1 (Class I) + Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$109.00
$128.62 inclGST