Fastron Electronics GT-D-C-SP02, 0-150VDC Voltage Transducer, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-C-SP02
Control Output
4-20mA
Input
0 - 150VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
THV302GB-2000V Voltage Transducer, Vpn = 2000V, 24VDC Supply, 4-20mA Analogue Output, 6kV Isolation
Features
Bandwidth DC Only
4-20mA Unipolar Analogue Output
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
YHDC Part Number
THV302GB-2000V
Technology
Closed Loop Hall Effect
Aperture
No Aperture
Supply Voltage
24 VDC, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 2000V
Measurement Range
+/- 2000V
Output
4 mA at 0V, to 20mA @Vpn
Isolation
6 kV
Bandwidth
DC Only
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
375g
Factory Pack Quantity
4
Â
Datasheet
Product DatasheetÂ
Gigavac GX11LCB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 240VAC Coil, 122cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX11LCB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
240VAC
Load Current
150+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
122cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Equivalent Parts
Fastron FC5-S-1U-2-G-2 PID Controller, 100-240VAC with 2 Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-1U-2-G-2
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron FC5-S-1A-2-G-2 PID Controller, 100-240VAC with 2 Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-1A-2-G-2
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
GIC Controls, 30A6B1, Hours Run Meter 90-264VAC/270-460VAC, Din Rail Mount
90-264VAC/270-460VAC
6 Digit Display
99999.9 Hours
Din Rail Mount
Datasheet
Product Datasheet
SN2546B, Crimp Tool/Pliers with SN2546B Jaw, Dupont Crimper 2.54/4.0/6.0 mm for EPS, Ferrul, JST, XH, Molex Connectors
Specification
Part Number:
SN-2546B
Series:
Dupont Multi 2.54/4.0/6.0
Jaw Type
SN2546B
Length:
7.67 Inch
Wire Size:
AWG23-16
Keyed:
Yes, A key
Color:
Black/Red/Blue
Material:
Metal/Plastic
Shape:
Rectangular
Connector Style:
Plug
Cavities:
4
Holds Pin/Socket:
Holds
Â
Â
Features
Â
Small size: The crimping tool is small in size and light in weight, easy to carry and store.
Excellent product: The crimping tool is made of high-quality stainless steel, which is durable and has a long service life.
Multi purpose uses: The crimping tool can be used to open and close wires, such as cable cutters, carabiners, etc.
SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers
Â
Features
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
2Â x Pulse Outputs (2 x configurable)
Â
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM54-MODBUS-MID
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
500V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2Â x Passive (Configurable)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Â
Crydom HS151DR-D1D40, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 29A @ 40 Deg C, 100VDC Load
Features
Ratings from 7A to 100 Amp @ 1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS151DR + D1D40
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5 - 32VDC
Load Current
29 Amp DC @ 40 Deg C
Surge Capability
106 Amp DC
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Reccomended Load Voltage
1-72 VDC
Max Load Voltage
100 VDC
Termination Style
Screw Terminals
Dimensions
L:97mm x W:45mm x D:142.8mm
Unit Weight
450g
Factory Pack Qty
10
Â
Datasheet
HS151DR Datasheet
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom CMD2450, Solid State Relay, Single Phase 3-32VDC Control, 50A, 24-280VAC Load
Features
Ratings from 25A to 90 Amp @ 24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CMD2450
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
D2440
HD4850
CY9008
CWD2450P
HD6050
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies