Crydom D53TP25D-10, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, Random Crossing
Features
Ratings from 25A to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP25D-10
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
25 Amp (rms) per Phase
Surge Capability
239 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
BLR-Q(U)12R MB(3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ
Single CT Sensing
32nd Harmonic Measurement
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.9 to 0.9 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 12 steps
Measurement System - Automatic/Manual
50-530VAC Measurement
100-132V / 207-253VAC (L-N) Aux Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
RS485 Modbus RTU
Â
Specification
Beluk Part Number
BLR-Q(U)12R MB / 3ACM12R-BEL-O-QMB
Function
Reactive Power Correction & Power Quality Analyser
Nominal Voltage (Un)
50-530VAC Line to Line
Supply Voltage
100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A
Relay Rating
250VAC/5Amp
Static Output Rating (T Models)
8-48VDC / 100mA
Internal 2MB LoggerÂ
Optional
3 x CT MeasurementÂ
Optional
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature/Fan/THD Alarm
1 x Relay as above
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.90 IND - 0.90 CAP
Number of Output Relays
12
Smallest Capacitor Current
10mA
CT Input Range
15mA - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Modbus RTU
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
Trent DP18, 18 Module Compact Distribution Boards, Panel Mounted IP40 with Terminal Block, Neutral bar and DIN Rail
Features
Latching Door/Window
IP40 Protection Class
RAL 7035
Double Insulation
IEC 60670-1, IEC 60670-24
Installation Temperature -20 to 60 Deg C
Glow Wire Test 650 Deg C
Datasheet
Product Datasheet
LEM FRS 3000-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 3000-SBI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
3000 Amp
Measurement Range
+/-9000 Amp
Overload Rating
N/A
Output
4-20mA Bipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Eastron Smart X72-5G, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, 4 Digital/Tariff Inputs, Modbus RTU RS485 Comms, Self Powered
Metering and Numerical Display
Adjustable tariff clock (Optional 4 Tariffs), display of electric energy consumption in optional currency
Modbus RTU as standard
True RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Â
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Â
Features :
Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.).
Accuracy class 1
Optional 2 or 4 tariff inputs,
Digital Output and Input
Ethernet communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD with Dual Metering and PF Displays
Specification
Eastron Part Number
Smart X72-5G
Functions
Power Quality Meter, Energy Meter
Aux Supply
65-276VAC/90-380VDC
Nominal Measurement Range
50-480V L-L, 1/5 Amp
Maximum Measurement Range
480V L-L, 1/5 Amp
Pulse Outputs
2 x Shared with Digital outputs
Alarm
2 x Digital Outputs (shared with Pulse function)
Tariff Input
4 Digital Inputs
Accuracy
Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
2.5kV (1 Min)
RS485
2400-38400 b/s
Weight
500g
Certification
MID, UL
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Operating Temperature
-25 →+55 °C
Â
Datasheet
User Manual
Fastron Electronics GTD-DV6-D-11, DC Voltage Transducer, 0-300VDC input, 22-60VAC/DC aux, Dual 4-20mA outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DV6-D-11
Conditioned Output
2 x 4-20mA (Average RMS)
Input
0 - 300VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Hanyoung Nux UP18RD-8NA-C, Inductive Proximity Sensor M18 Cylindrical Unshielded, 8mm Sensing Distance (0-6.4mm Set), 12-24VDC NPN Output, Normally Open NO, Connector TypeUP18RD-8NA-C, Inductive Proximity Sensor M18 Cylindrical Unshielded, 8mm Sensing Distance (0-6.4mm Set), 12-24VDC NPN Output, Normally Open NO, Connector Type
200HZ Response
12-24VDC Operating voltage
200mA Maximum Output
Built in reverse power, surge, overcurrent protection
50 Meg Ohm Insulation residtance
Specification
Hanyoung Nux Part NumberFastron NArt Number
UP18RD-8NA-C
Sensor Type
Inductive Proximity Sensor M18 Cylindrical Unshielded
No of Wires
3
Material
Stainless Steel Body / Face PBT / Cable Holder Polyester Elastomer
Shielded
NO
Sensing Distance
4mm (0-3.2mm Set)
Frequency Response
200Hz
Output Type
12-24VDC NPN Normally Open
Sensor Thread Size
M18
Standard Target
Ferrous Metal 8 x 8 x 1mm
Approvals
CE
Residual Voltage
1.5V
Current Consumption
6mA
Ambient Operating Temperature
-25 to 70 Deg C
Insulation Resistance
50 Meg Ohm (500V dc in Megohms) between all terminals and case
Dielectric Strength
1500Vac 1 min at 50/60Hz Between all terminals and case
Shock Resistance
500m/s^2, 3 times in each direction
Vibration Resistance
10-55Hz Double amplitude: 1.5mm, 2 hours in each direction X,Y,Z)
Termination
Cable Type (stdnard 2M cabel length), connector cable type, connector type
Colour
NPN:Green, NPN:Navy
Protection Class
IP67
Approvals
CE
Weight
130g
Factory NAck Qty
1
Datasheet
Product Datasheet
Product Datasheet
Crydom CXE240D5, Solid State Relay, PCB or Socket Mount, 15-32VDC Control, 5 Amp, 12-280VAC Load
Features
Ratings up to 5 Amp @ 280VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CXE240D5
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
15-32VDC
Load Current
5 Amp (rms)
Surge Capability
250 Amp (peak)
Special Feature
None
Mounting Style
PCB Mount
Load Voltage Range
12-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
DIN Rail Holder
Din Rail Holder
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics BTCS/R-M-A2-EI, PID Controller 48x48mm, 85-265VAC, Relay Output 2 Alarms, Event input (2xSV ), Multirange TC/RTD/Relay 3 Amp (Resistive)Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32 Step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Part Number
BTCS/R-M-A2-EI
Control Output
4-20mA
Input
Multirange 4-20mA/RTD/Thermocouple (Optional Linear Voltage/Current other than Relay 3 Amp (Resistive)Refer to datasheet)
Option 1
2nd Alarm
Option 2
Event Input (2 x SV)
Mounting Style
48x48mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
CE
Yes
Â
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Gigavac P195FDA, MiniTactor Contactor SPST-NO, 80 AMP, 1200VDC, 48VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Features
Perfect for Photovoltaic/Battery Systems
Hermetically Sealed (Patented) rated to 175 Deg C
High Efficiency Dual DC Coils - 12,24,48VDC options
Ideal for battery powered systems or where low power is needed
Built in Coils suppression for all DC Coils
Small and lightweight
Flexible package for installation
Chassi level power terminals
Specification
Gigavac Part Number
P195FDA
Main Contact Type
SPST-NO
Auxiliary Contact Type
N/A
Coil Voltage
48VDC
Load Current
80 Amp
Mechanical Life @ 0 Amp
100,000 Operations
Dielectric at Sea Level
4.3kV rms
Control Input Terminals
M3 Screw
Special Feature
N/A
Mounting Style
Panel Mount (M4)
Load Voltage Range
1200VDC
Standards
UL508, NEC 690.11 and 690.12 DC
Termination Style
M4 Screw
Unit Weight
135g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
Â
LEM FRS 1500-SUI, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 1500-SUI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
1500 Amp
Measurement Range
+/-4500 Amp
Overload Rating
N/A
Output
4-20mA Unipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â