Crydom HD4850K-10, Solid State Relay, Single Phase 3-32VDC Control, 50A, 48-530VAC Load, Random Crossing, Gen 3 style
Features
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HD4850K-10
Switching Type
Random Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Gen 3 Terminals
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron TC5-H-W-2-T/R-2, 100-240VAC PID Controller with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x96mm,Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-H-W-2-T/R-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/12VDC @ 20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
48x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Approvals
CE
Â
Datasheet
TC5 Datasheet and User Manual
GMDA-D22-A-AA, Dual DC Voltage Transmitter with Dual Output and separate scale, 2 x 0-10VDC, 100-240VAC/DC Aux, 2 x 4-20mA Outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMDA-D22-A-AA
Control Output
2 x 4-20mA Independent Analogue Outputs
Input
2 x 0-10V Independent
Alarm Type
2Â x SPDT CO Relay 3 Amp (2 Independent Alarms)
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-100%
Zero Adjustment Range
+/-100%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Fastron TC5-M-1U-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 72x72mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-M-1U-2-T/R-2
Control Output
0-10V
Input
Multirange Type,K,E,J,Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 72x72mm with SSR/Relay output)
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet
TC5 Datasheet and User Manual
Fastron TC5-W-W-2-A-2 PID Controller 100-240VAC, with 2 3 Amp Relay Alarms, 4-20mA Input, 96x48mm, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-W-W-2-A-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ 12VDC @20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x48mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet
TC5 Datasheet and User Manual
Crydom HS259DR, Panel and DIN Rail Mount Heatsink for Solid State Relays, 25 Amp @ 40 Deg C (with Nova 50 Amp SSR), L:81mm x W:22.5mm x D:80mm, 2.5°C/W
Features
DIN Rail or Nova Series Panel Mount heat sink types
Suitable for 22.5mm width SSR Mounting
Black anodised for professional look
Spec
Crydom Part Number
HS259DR
Mounting Type
Panel and Din Rail Mount
Suitable SSR Rating
25/50 Amp
Dimensions (without SSR)
L:81mm x W:22.5mm x D:80mm
Thermal Impedance
2.5°C/W
Load Current @ 40 Deg C
25 Amp (With 50 Amp Nova Series SSR)
Load Current @ 50 Deg C
17 Amp (With 50 Amp Nova Series SSR)
Unit Weight
240g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
A53TP50D + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
A53TP50D + HS212
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Â
Datasheet
HS103DR
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
RCS-5A, 5 Amp Output, Class 0.5 INTEGRATOR ONLY Three Phase 500/1000/2500/5000/10000/25000/50000 Amp AC Selectable Measurement Ranges
RCS-5A Integator by Magnelab converts AC input current of up to 50000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate the coils.Â
Magnelab Coils come with 10 year warranty
Â
Specification
Magnelab Part Number
RCS-5A
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000/10000/25000/50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Timer Chronos2 88827103 Timer Chronos2 MUR3 20-30VDC & 20- 264 VAC, Can be replaced by BM1R05MV1 (5 Amp)
MUR3 Timers Syrline 17.5 mm - 1 C/O Relay 8A :
Multi-range (0.1s - 100hrs)
Multi-voltage 12 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
3-wire PNP sensor compatible
Multifunction Timers Includes The Following :
Function A Delay on energisation 1 relay
Function Ac Timing after closing and opening of control contact 1 relay
Function At Timing on energisation with memory 1 relay
Function B Timing on impulse one shot 1 relay
Function Bw Timing pulse output (adjustable)
Function C Timing after impulse 1 relay
Function D Flip-flop Pause start 1 relay
Function Di Flip-flop Pulse start 1 relay
Function H Timing on energisation 1 relay
Function Ht Delay on energisation with memory 1 relay
Specification
Crouzet Part Number
88827103 (Syr-Line Timer SinglePole Double Throw 1 x 8A Multifunction, 12 - 240VAC/DC, 17.5 mm)
Function
Multifunction Timer A - Ac - At - B - Bw - C - D - Di - H - Ht
Nominal Voltage
12 → 240 V AC/DC
Digital Output
1 x C/O (DPDT) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.1s - 1s - 10s - 1 min - 10min - 1h, 10h, 100h
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Cross Reference
Can Be Replaced by BM1R05MV1 (5 Amp) or BM1R16MV1
Can Be Replaced by BM1R05MV1 (5 Amp) or BM1R16MV1
Replaces MRU1
Shinko JIR301M Series Digital Indicator
Converter function are standard features
5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
3 Alarms as standard feature
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output
Each unit needs just 96 x 48mm panel space
EC Compliant (Details)
Specification
Shinko Part Number
JIR301M
Control Output
N/A
Input
Multirange (refer to datasheet)
Alarm
3 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
Retransmission
Mounting Style
96 x 48mm Panel Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
240g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
JIR Series Brochure
JIR Series User Manual
JIR Series Comms Manual
Fastron Electronics GTD-TT1-D-11, DC Voltage Transducer, - 50 to 50 Deg C input, 22-60VAC/DC aux, Dual 4-20mA Outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-TT1-D-11
Conditioned Output
2 x 4-20mA (Average RMS)
Input
- 50 Deg C to 50 Deg C
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet