Search results for "텔레@coinsp24^^소액결제세탁trc20사는법"
-
AKR 5 C420L, AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 5 C420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FKPC200-400 (FKPC-240-CE), Single Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, CE Approved, See FKPC-200-400 REV 2 FOR UPDATED DESIGN
Free Aus Post Shipping for $300 SpendFastron FKPC200-400 (FKPC-240-CE), Single Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, CE Approved, See FKPC-200-400 REV 2 FOR UPDATED DESIGN Rev 1 Supports Input:4-20mA,2-10V, 1-5V or 10K POT Proportional Phase Control Input Suitable for SCR Blocks up to 3000 Amp Instantaneous turn-on output CE Approval (Pending) Can Replace Semikron Semi-PCM 2 SKPC200 for most applications. Please take care to connect 240VAC Aux Supply Seperately and connect the gate leads to cathode rather than anode Specification Fastron part Number FKPC200-400 (Previously FKPC-240-CE) (Possible Replacement to SKPC200-240) Switching Type Phase Angle (Random Crossing) Control Voltage 4-20mA,2-10V,1-5V,10K POT Proportional Input Load Current Based on SCR Stack Special Feature Single Phase Proportional Controller/Trigger Mounting Style Panel Mount Load Voltage Range 200-450VAC +10% Termination Style Barrier Strip Screw Dimensions 105 x 90 x 40mm Certifications EMC EN 61000-6-3:2007+A1:2011, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A1:2019, EN IEC 61000-6-1:2019 Certifications LVD Low Voltage Directive 2014/35/EU, EN IEC 60947-1:2021 Unit Weight 400g Factory Pack Qty 20 Datasheet and User Manual User Manual FKPC wiring Half Controlled M505012F Crydom Bridge for up to 240VAC - 400VAC Load FKPC wiring Half Controlled SKCH28/16 Bridge for up to 240VAC - 400VAC Load FKPC AC Switch Wiring
-
Thyro ECO A1A 400-25 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 25 Amp 230VAC +10%/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode
Advanced Energy Thyro A 1A ECO Series 3 Phase SCR Power Controller, 230VAC +10%/-57%, Voltage Control only, 25 to 125 Amp Ratings, Phase(VAR), Burst(TAKT), SWITCH Operating Modes Features 230VAC +10%/-57%, Voltage Control only +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro A 1A ECO Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control only +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$887.04
$1,046.71 inclGST -
LV 200-AW 2 /6400, C/L Voltage Transducer 6.4kV, 80mA Output, +/-15/24VDC Supply
Heavy Item - No Free ShippingLEM LV 200-AW 2 /6400, C/L Voltage Transducer 6.4kV, 80mA Output, +/-15/24VDC Supply Features Bipolar and insulated voltage measurement up tp 6000VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 200-AW 2 /6400 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15/24 VDC Bipolar, Isolated Primary RMS Voltage 6400V Measurement Range +/- 9600 V Output 80 mA Isolation 12 kV Response 500uS Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style M5 threaded studs Unit Weight 2000g Factory Pack Quantity 6 Datasheet Product Datasheet
-
5500.2219, 2 Stage EMC (RFI) Line Filter, FSW2.130.20/0.5 20A, 250VAC, Very High Symmetrical and Asymmetrical Attenuation
Free Aus Post Shipping for $300 SpendSchurter 5500-2219, 2 Stage EMC (RFI) Line Filter for Single Phase systems Features Line filter in standard and medical version 2-stage - high attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Other Versions on Request Version with wire connection Version with varistor for overvoltage protection Specification Schurter Part Number 5500-2219 Rated Voltage 250V Rated Current 20A Filter Stages 2 Stage Operating Temperature -25°C to 85°C Filter Type Very High Symmetrical and Asymmetrical Attenuation Leakage Current 0.5mA Mounting Panel Mount - Case FF Material Metal Termination Style Screw Weight 840g Factory Pack Qty 4 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
-
FGS1-C/3-275-20, 275VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/3-275-20, 275VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/3-275-20 Nominal Voltage 275VAC No of Poles 3 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$90.00
$106.20 inclGST -
Thyro-A-2A-400-350-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option
Advanced Energy Thyro-A-2A-400-350-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-350-HRL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,220.50
$7,340.19 inclGST -
WM3-6 230PB, kWh Sub Meter, 230/400VAC +20/-15%, Three or Single Phase, 65 Amp Direct Connect, Bidirectional Counter, Pulse Output & IR Comms, DIN Rail Mount
Free Aus Post Shipping for $300 SpendIskra Doo WM3-6 230PB Three Phase Power Meter with Pulse Output & IR Comms 65 Amp direct connect, no CT's required Ultra slim 3 DIN IR Communication as standard Pulse Output Optional RS485 communication up to 19,200 bit/s True RMS values of currents and voltages Measurements of active, reactive power Accuracy class 1 The meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of Active and Reactive Power Optional Pulse Output RS485 Comms IR Comms Graphic LCD with illumination Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number WM3-6 230PB Functions Energy Meter Supply Voltage 230V L-N, 400V L-L 5 Amp -20% +15% < 5VA Nominal Measurement Range 230V L-N, 5 Amp -20% +15% Maximum Measurement Range 230V L-N, 5 Amp -20% +15% Nominal Current Input 3 x 65 Amp AC Direct Connect Infra Red Output 19200 bit/s Tariff Input N/A (Optional) Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Dimensions 53.6 x 84 x 69.4mm (3 DIN) Pulse Output Yes Isolation 4kV RS485 (Optional) 1200-19200 b/s Weight 270g Certification UL, CSA, ROHS Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
FGM6DC-2PL-400 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1000VDC
Heavy Item - No Free ShippingTrent FGM6DC-2PL-400 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1000VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1000VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-2PL-400 400A Functions 2 Pole DC MCCB Nominal Voltage 1000VDC Nominal Current Range 400 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed) Weight 5.7kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet CE Declaration
-
Thyro ECO A3A 400-25 E L3, 3 Phase, SCR Controller 25 Amp Rating, Phase(VAR), Burst(TAKT), Switch Operating Mode, Voltage Control only
Advanced Energy Thyro ECO A3A 400-25 E L3, 3 Phase, SCR Controller 25 Amp Rating, Phase(VAR), Burst(TAKT), Switch Operating Mode, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage Control Programmable Relay Alarm Output 3 Phase, Phase Angle, Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro ECO A3A 400-25 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,598.75
$3,066.53 inclGST -
RXC15P9QA, Contactor SPST-NO, 225+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, Exceeds IP69
Free Aus Post Shipping for $300 SpendRincon Power RXC15P9QA, Contactor SPST-NO, 225+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, Exceeds IP69 Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Rincon Power Part Number GX11CAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 1000VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
FBS RK SC 110, 110VDC 2 Pole Surge Protection Device for Unbalanced IT Systems, 5kA, LPZ 0 -2 or higher
FBS RK SC 110, 110VDC 2 Pole Surge Protection Device for Unbalanced IT Systems, 5kA, LPZ 0 -2 or higher Application Unbalanced IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK SC 48 Nominal Voltage 48VDC No of Poles 2 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use Unbalanced IT Communications Line/signals Protection modes L1+/L2+/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$29.00
$34.22 inclGST