FGS1-C/4-385-20, 385VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-385-20, 385VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-385-20 Nominal Voltage 385VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
5500.2047, 2 Stage EMC (RFI) Line Filter, FMW2.55.20/5, 250VAC, 20 Amp, Very High Symmetrical Attenuation
Free Aus Post Shipping for $300 Spend2 Stage EMC (RFI) Line Filter, FMW2-55-20/5, 250VAC, 20 Amp, Very High Symmetrical Attenuation Datasheet Product Datasheet
-
Thyro-A-2A-400-350-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options
Advanced Energy Thyro-A-2A-400-350-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-350-HRLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$7,229.20
$8,530.46 inclGST -
WM1-6 230WWNB, kWh Meter, 230VAC +/-20%, Single Phase, 65 Amp Direct Connect, Bidirectional Counter, DIN Rail Mount
Free Aus Post Shipping for $300 SpendIskra Doo WM1-6 Series Single Phase Power Meter 65 Amp direct connect, no CT's required Ultra slim 2 DIN Optional RS485 communication up to 19,200 bit/s True RMS values of currents and voltages Measurements of active, reactive power Accuracy class 1 The meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of Active and Reactive Power Optional Pulse Output Graphic LCD with illumination Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number WM1-6 230WWNB Functions Energy Meter Bidirectional Supply Voltage 230V L-N, 5 Amp +/-20% < 5VA Nominal Measurement Range 230V L-N, 5 Amp +/-20% Maximum Measurement Range 230V L-N, 5 Amp +/-20% Nominal Current Input 65 Amp AC Direct Connect Infra Red Output 19200 bit/s Tariff Input N/A (Optional) Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Dimensions 36 x 90 x 64mm (2 DIN) Pulse Output N/A Isolation 4kV RS485 1200-19200 b/s (Optional) Weight 270g Certification UL, CSA, ROHS Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
Thyro-A-2A-400-280-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option
Advanced Energy Thyro-A-2A-400-280-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-280-HRL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$5,242.60
$6,186.27 inclGST -
FGS1-C/4-320-20, 320VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-320-20, 320VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-320-20 Nominal Voltage 320VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
FRI8-05/A, Current Monitoring Relay AC 2-20 Amp, Adjustable Range, 9mm Aperture Universal 24-240VAC 24VDC
Free Aus Post Shipping for $300 SpendFastron FRI 8-05/A, Current Monitoring Relay AC 2-20 Amp, Adjustable Range, 9mm Aperture Universal 24-240VAC 24VDC FRI8-05/A Series serves to monitor AC currents 2,4,6,8,10,12,14,16,18,20 up to 20 Amp, and provides Relay alarm output with Over/Undercurrent selection by jumper. Can replace Crouzet 84871122 Features : ?? Current transformer is a part of the product. Inside this transformer there is a wire which senses the volume of flowing current Non Invasive measurement Galvanically separates monitored circuit Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measuring current Current withstand up to 100 A Output contact: 1 x changeover/SPST 8 A Clamp terminals 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI8-05/A Cable Aperture 9mm Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range -15 %; ? % Current Range 1 - 20 A (AC 50 Hz) Current Trip Adjustment 2,4,6,8,10,12,14,16,18,20 Amp Setpoints Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 100 Amp Time delay T1 max. 500 ms Time delay T2 N/A Output SPDT Relay 8 Amp Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 8 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... ? ??C Storage temperature -30 ... ? ??C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage category III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Application Notes Monitoring relay FRI8-05/A serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multi voltage supply is an advantage.
-
DK 20 C420 B, Hall Effect DC Current Transducer, 5, 10, 20A DC, 4-20mA bipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 20 C420 B, Hall Effect DC Current Transducer, 5, 10, 20A DC, 4-20mA bipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 5, 10, 20Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C420 B Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 5,10,20 Amp Selectable Response Time < 100ms Output Bipolar 4-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Thyro-A-2A-400-280-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options
Advanced Energy Thyro-A-2A-400-280-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-280-HRLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,155.60
$7,263.61 inclGST -
TC-FGM6DC-2P-800, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY
Trent TC-FGM6DC-2P-800 100A, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-2P-800 Functions Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame size 800 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$15.00
$17.70 inclGST -
Thyro-A-2A-400-170-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options
Advanced Energy Thyro-A-2A-400-170-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-170-HRLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$4,519.90
$5,333.48 inclGST -
Thyro-ECO-A2A-400-80 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 80 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-80 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 80 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-80 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,681.91
$3,164.65 inclGST